Fault
-
Product
PXI 11-Channel 2A Fault Insert Switch
40-202-101
Fault Insertion Unit
This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
Product
PXI 5A Fault Insertion Switch 10-Channel
40-196-001
Fault Insertion Unit
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
Single Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-101
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel
50-201-004
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
PXI Single Bus 64-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-401
Fault Insertion Unit
The Single Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXIe 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
42-205-008
Fault Insertion Unit
The 42-205-008 (PXIe) is an 8-channel fault insertion switch designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. It is available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
Dual Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-102
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI 5A Fault Insertion Switch 20-Chan 1-Bus
40-198-001
Fault Insertion Unit
The 40-198 is a 20 Channel Fault Insertion switch, primarily designed for the simulation of fault conditions in automotive/avionics applications involving the reliability testing of safety critical controllers.
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
Fault Insertion Unit
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
Product
PXI/PXIe Fault Insertion Switch, 74-Chan 2A, N/C Through Relays, Fault Buses on M & U
42-190C-012
Fault Insertion Unit
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Ground Fault Detectors
-
STB Electrical Test Equipment, Inc
STB's convenient Ground Fault Detectors may be operated with one hand and are ideal for preventative maintenance. Ground Fault Detectors indicate ground faults and electrical leakage while equipment is in operation.
-
Product
Visual Fault Locator
-
OrienTek Optical Technology Ltd.
powerful, mini visual laser source for fiber fault locating. It has attractive design and small size and it is easy to operate. ● Bright red laser at 650nm● Pulsed and CW operation● Outpower: 1mw,10mw,20mw,30mw● 2.5mm universal connector● 40 hours of operation(1mW)● Pocket size design● 1.25 mm adapter for LC (optional)
-
Product
PXI Fault Insertion Switch, 6-Channel, Two Fault Buses, 30 A, Hardware Interlock
40-191B-012-HI
Fault Insertion Unit
The 40-191B-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
Product
PXI Dual Bus 32-Chan 2A Fault Insert Switch
40-190B-202
Fault Insertion Unit
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Cable Fault Locator
-
We are one of the leading manufacturers, exporters of suppliers of a premium quality range of Cable Fault Locator that is extensively used to trace and locate the fault of underground cables. This fault locator is manufactured at our hi-tech manufacturing unit as per international quality standards under the supervision of our professionals using superior quality components. Offered fault locator is made available in different specifications to meet the diverse requirements of the clients. Our honorable clients can avail this Cable Fault Locator from us at industry-leading prices.
-
Product
Thumpers and Cable Fault Location
-
Cable testing can be broken down to different steps of the process, starting with a time domain reflectometer test to look for an incident signal on the line or, in some high resistance situations, VLF testing. These tests will identify a fault, allowing you to move on to pre-locating it. In some low resistance faults this will occur alongside the identification via the TDR.
-
Product
PXI Single Bus 64-Ch 2A Fault Insertion Switch
40-190B-101
Fault Insertion Unit
The Single Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
PXI Fault Insertion Switch, 6-channel, Two Fault Buses, 10 A, Hardware Interlock
40-192A-012-HI
Fault Insertion Unit
The 40-192A-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test:
-
Product
PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module
778572-10
Fault Insertion Unit
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
Product
Fault Locator
VM-510FFL+
-
Finding the location of an underground cable fault just became easier with the VM-510FFL+ Standalone A-frame locator. Now locating a suspect cable and finding the fault can be done with the VM-510FFL+ and a compatible transmitter. There is no longer a need for a separate utility locator with cables connecting to it. After connecting a compatible transmitter to the line and placing it in a Fault-Find mode, use the simple to operate four button controls of the VM-510FFL+ to locate and stay on the cable path while pinpointing the sheath or ground fault.
-
Product
Fault Passage Indicator for Lines
LineTroll R400D
-
LineTroll R400D Fault Indicator indicates earth- and short-circuit faults and can distinguish between permanent and transient faults. The indicator has two sensors and use both the electrical field and the magnetical field to detect faults on all three phases.
-
Product
Visual Fault Locator
STC-VFL301
-
Shanghai Stone Communication tech Co., Ltd
STC-VFL301 is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in optical network.
-
Product
Cable Fault Locator
TX2003
-
6 km (19,000ft) 0.5mtr dead Zone Selectable Cable Impedance Warble Tone Generator Rapid Fault Location Large 128x64 LCD with Backlight Scratch Resistant Display Environmental Protection IP54 CE Approved 3yrs Manufacturers Warranty 60 Hours Battery Life
-
Product
Cable Fault Locator
TX2002
-
Lowest Cost Full Specification Professional Graphical TDR Rugged Palm Top Design 350g (12oz) 5 Measurement Ranges up to 3500m (11,500ft) 50, 75 & 100 ohm Selectable Cable Impedance Built in Tone Generator for Pair Tracing & Identification Suitable for testing all Communications Cables Water & Dust Proof to IP54 Complete with tool-belt holster & test leads
-
Product
Mission Critical, Fault Tolerant Power Supplies
Series HSF
-
- Hot-swappable plug-in power supplies.- Designed to be combined in an N+1 fault-tolerant power system.- Front panel voltage adjustment trimmer for adjustment of output voltage.- Built-in forced current sharing and or-ing diodes.- May also be used independently as a multi-output power supply.- Designed to be sustainable - new models are backward compatible with existing racks.- Available in 1U and 3U sizes. Mounts in 19-, 23-, and 24-inch equipment racks.- All models include power factor correction (PFC).- Full service customized DC power distribution systems can match power supply output(s) with your load(s).- I/O connections via 24 pin connector that plugs into rack adapter. External connections are made via rack adapter.- Surface mount technology permits minimum mounting space.- Entire RA 19 racks populated with HSF power supplies can be connected in parallel, parallel-redundant or series.- HSF are CE Marked per per the LVD, EMC and RoHS 2 Directives. See applicable Declaration of Conformity.- Compliant with UL 8750, Standard for LED Equipment,- Watch video of NEBS GR-63-CORE earthquake and office vibration testing.
-
Product
Fault Locator
BIDOYNG
-
BIDOYNG fits into existing LV fuse positions using two LV fuses in parallel, creating a robust single-shot auto-recloser. The primary fuse carries the load current until a fault causes it to operate. Then, after a user programmed delay, the secondary fuse is switched in and the network re-energised without customer interruption.
-
Product
PCI Fault Insertion Switch Cards
-
Pickering's PCI Fault/Signal Insertion Switch Cards feature a breakout arrangement that allows faults to be attached to the sensor lines, this includes the breaking of a connection or the adding of defect all of which can simulate connectivity problems in the system.
-
Product
Cable Fault Locators
-
Wuhan Sunma Technology Co., Ltd.
Visual Fault Locator, we can understand its function in the letter. It could be regarded to be part of OTDR and the fiber fault locator is cheap. Fiber visual fault locator is a kind of device which is able to locate the break-point, bending or cracking of the fiber glass. It can also locate the fault of OTDR dead zone and make fiber identification from one end to the other end. Designed with a FC,SC,ST universal adapter, this fiber testing red light is used without any other type of additional adapters, it can locates fault up to 10km in fiber cable. SunmaFiber also supply a new kind of Cable Fault Locator, Fiber laser tester/ fiber laser pen, it can locates fault up to 30km in fiber cable. Contact us at Sales@SunmaFiber.com or Live Chat with us. Save your money & time right now! Buy from fiber optic supplies at SunmaFiber.com with your confidence.





























