Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
MS-M 26-Pin RF Cable to SMB, 0.5m
40-979-526-0.5m-SMB
The MS-M RF 26-Pin cable assembly is constructed from RG178 Silver Plated Copper Clad Steel Wire with PVC insulation and an attenuation of 1.08dB/m at 400MHz. Screwlocks are provided to secure the MS-M connector to the associated product.
-
product
Outdoor AGC Optical Node
SR812B
Hangzhou Softel Optic Co., Ltd.
SR812B optical receiver is our new development products that especially used in CATV network. The pre-amp adopts GaAs MMIC amplify module and the post-amp adopts GaAs power doubler amplify module .Support specifical attenuation and equalization inserts if you want.Or as per customer, adopts other module.With optimization design and plentiful technical experience that made this equipment with high performance specification. It is a ideal model for CATV network.
-
product
High-Voltage Differential Probe, 200 MHz
N2805A
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
product
RF Milliwatt Meters
Type NDB-2 and NDB-3
National RF’s Type NDB-2 and NDB-3 RF Milliwatt Meters are affordable pieces of test equipment for both the RF laboratory and the home experimenter. Both provide a digital reading of RF power in dB reference 1 milliwatt of power into a 50 ohm load (i.e. 0 dBm). The circuitry consists of a low noise logarithmic amplifier that drives a digital A/D converting meter circuit. The lowest power levels that can be read are about –73 dBm (approximately 40 microvolts or .00000003 milliwatts). The maximum power input should not exceed 10 milliwatts (+10 dBm or .010 watts) when inputed without attenuation. An internal attenuator is provided and described in the next section.
-
product
0.1Hz-2MHz AM/FM Functional Generator
MFG-8202
Features:• Low distortion, high stability• Linear and logarithmic sweep function• Sweep time and width adjustable• External Voltage Control Frequency (VCF)• Internal & external modulation (AM/FM) with modulation control• Output signal compatible with TTL/CMOS• Seven types of waveforms such as sine, square, triangle and ramp• 5W power output (ONLY for model no with “B”)• DC offset and 40bD attenuation can be applied to main output signal• Built-in frequency meter 0.1Hz~30MHz
-
product
ADSL / 2 / 2+ Handheld VoIP Tester
QuickTest 500
*Rapid Testing. The QuickTest 500 ADSL2+ Tester's automatic Service Verification Test Suite starts as soon as you switch on (results are typically obtained in less than 3 minutes)*Simple to use. Virtually no product training required with QuickTest 500 ADSL Tester*Configurable Pass / Fail Indicators on the LCD display and clearly presented in multi-colour LEDs on the front panel*No need to get a laptop out*Save and name up to 16 test results at any one time*Line Voltage LED indicates poor, missing or excessive Line Voltage*ADSL/2/2+ Test LEDs to indicate if ADSL Showtime achieved*In Service LED indicates problems with PPP or IP layer*LEDs to indicate problems with the Trained Line Rate, poor Noise Margin or excessive Line Attenuation
-
product
Handheld Singlemode Multimode
OTDR X60
Palm OTDR X-60 is a very reliable and good performance OTDR, it can measure the optical fiber length, transmission attenuation of optical fiber, attenuation of splice, and failure location, etc accurately. It is widely used in the maintenance, construction and monitoring of cable line.
-
product
Oscilloscope Probe
Oscilloscope Probes can conduct signals up to 2.5 GHz, 300 V, or 500 Arms, even in extreme environments. They offer fixed attenuation of 10X or 100X or switchable attenuation between 1X and 10X. Oscilloscope Probes are offered in several types, including single-ended and differential, active and passive, voltage and current.
-
product
Variable Optical Attenuators
5420
The FOD 5418, 5419, 5420 Variable Optical Attenuators are designed for singlemode application at 1310 and 1550 nm or multimode application at 850 and 1300 nm. They allow variable attenuation settings in range from 0 to 80 dB with resolution 0.05 dB.
-
product
Outdoor AGC Optical Node
SR812M
Hangzhou Softel Optic Co., Ltd.
SR812M series are our universal CATV network optical receiver with network management responder. The pre-amp adopts all-GaAs MMIC amplify and the post-amp adopts GaAs power double amplify module (This series has two models, M model RF attenuation and equilibrium adopt the continuously adjustable design, MF model with different fixed attenuation and equilibrium inserters for user option. Users can also choose more targeted high quality modules according to actual requirements). Optimized circuit design, coupled with our years professional RF design experience, the equipment achieve high performance index. It is an ideal model for CATV network.
-
product
÷10, 500 MHz, 10 MΩ, Passive Probe (Total of 1 Per Channel)
PP008-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Fiber Strain Measurement System
SPL500
The SPL500 is a fiber strain measurement system that measures fiber elongation and attenuation simultaneously during mechanical stressing of the cable. The SPL500 is designed to produce accurate measurements quickly and with confidence.
-
product
0.1Hz-3.7GHz Frequency Counter
FC-3000
Features:*Frequency measuring range: 0.1Hz to 100MHz in A input, 80 MHz to 3.0GHz in C input.*Period,Total and RPM measurement for input A*9 Digit display with 0.01mHz resolution in 1 Sec (By Ext.Reference signal).*RS-232C serial interface function for communication with computer.*High sensitivity Extemal reference input function(>=1.5Vrms).*Peciprocal technique for high resolution at low counting frequencies .*Self check function executed to perform a automatic self diagnosis of various counter function.*Push-scanning for selecting Function and Gate time.*Low-pass filter(100KHz,-3dB)installed for removing noise signsl in low frequency measuring.*AC/DC coupling function(Selectable AC/CD Coupling)*10:1 Input Attenuation(Selectable×1/×10 Attenuator)*Data hold function
-
product
Transmittance Dust Measuring Devices
Maintaining a clear sightline even when dust concentrations are highTransmittance dust measuring devices transmit light through the entire duct. With this type of measurement, light attenuation indicates the concentration of dust inside the duct. These measuring devices are specially designed for medium to high dust concentrations and large duct diameters. Consequently, they are equally suited to emission and process monitoring as they are to hall monitoring applications.
-
product
Passive Probe, 1:1, 35 MHz, 1.3 M
N2870A
The N2870A passive probe offers DC to 35 MHz and 1:1 attenuation factor, making this probe ideal for low-level signal measurements.
-
product
Ku Band Gain Control Amplifier
Expanding Teledyne RF & Microwave's existing line of high frequency amplifiers, microwave gain controllable amplifiers are designed and biased for critical performance applications. One example covers 10-13 GHz, offers 45 dB unattenuated small signal gain with 15 dB attenuation range. Typical gain flatness is ±0.5 dB, +35 dBm third order intercept point, +22 dBm minimum 1-dB gain compression, and 3.5 dB unattenuated noise figure 4.5 dB at full attenuation. This is only one of a series of microwave controllable amplifiers currently in production.
-
product
Near Field Probes 30 MHz up to 3 GHz
RF1 set
The RF1 near field probe set consists of 4 passive near field probes for making measurements in the development phase of E-field and magnetic field in the ranges of 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF1 set allow for measurements close to the electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors in order to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
product
3x3 and 2x2 High NA Couplers
Feasa produces a range of Couplers Manufactured from high Numerical Aperture (NA) 80 micron fiber. High NA fiber has low bend attenuation compared to standard singlemode fiber.
-
product
Variable Optical Attenuator - MATRIQ
The VOA MATRIQ Series is a MEMS-based variable optical attenuator with fast attenuation speed, low insertion loss and in-built power meter. Its advanced power stabilization function lets you set and maintain the output power stability even when the input power fluctuates.It is available in singlemode, multimode and polarization maintaining fibre types and various wavelengths to suit a wide range of applications.With a stackable, space-saving design and intuitive software controls make it a valued addition to the optical lab or test bench.
-
product
High Voltage Probe Meters
Shanghai Beha Electronics Co., Ltd.
*High voltage test probe *is a high voltage probe that is used with Oscilloscope● Attenuation Ratio: 1000:1*Measuring range: AC 20KV/DC 30KV
-
product
Downhole Minimus
For deployments exceeding 100 metres in depth, we recommend the Downhole Minimus digitiser. Digitizing the data at source ensures that the origin can be definitively traced and not subject to attenuation during the travel to the surface; so signals are stronger and more reliable.
-
product
RF Reference Sources
The 27 GHz 96270A and 4 GHz 96040A Low Phase Noise Reference Sources are designed specifically for RF calibration, featuring a calibration-oriented interface, precision signal level and attenuation, high signal purity and precision low distortion modulation. Both instruments simplify the process of RF calibration by reducing the amount of equipment and simplifying the calculations required.
-
product
Voltage Variable Attenuators
Macom Technology Solutions Holdings Inc.
Voltage Variable Attenuators (VVA) from MACOM offer the ability to control the attenuation level relative to a voltage. Attenuation range is up to 30 dB covering frequency as high as 45 GHz. VVAs feature excellent return and insertion loss along with high IP3 in small SMT packages.
-
product
Entry Level Beam Profiling
BeamMic®
BeamMic is simplified set of measurement tools for the entry level beam analysis user. The camera-based beam profiling system consists of a camera and analysis software. Often times, this system will need to be used with beam attenuation or beam sizing accessories, depending on your laser application. BeamMic includes a complete set of high-accuracy measurements, and features a rich graphical interface. For the laser technician, this entry-level software will easily help you quickly become familiar with the many benefits of beam profiling.
-
product
Variable Optical Attenuator
CARY-VA3301B
The CARY-VA3301B handhold variable optical attenuator is used for continuously variableoptical signal attenuation. Since the variable optical attenuator is used in the laser system for the on-line testing, CARY-VA3301B can be used in the digital system of communicationdevices (such as: PHD, SDH) and also can be used in the CATV system testing.
-
product
Radiative Transfer Numerical Model
HydroLight
The HydroLight radiative transfer numerical model computes radiance distributions and related quantities (irradiances, reflectances, diffuse attenuation functions, etc.) in any water body.
-
product
Attenuators
The National RF line of attenuators are compact, affordable attenuators which are ideal for insertion between a direction finding antenna and a receiver/transceiver, to aid in the DF process. In addition, they may be used in the laboratory for a low-power, in-line attenuation purposes. The affordable price is achieved by utilizing standard 5% tolerance resistors and commercial hardware. For laboratory purposes, an attenuation versus frequency curve (to 500mMHz) is provided.
-
product
2 To 18 GHz 6 Channel Downconverter
Teledyne RF & Micrrowave's Six Channel 2 - 18 GHz (RF and LO) downconverter operates with an IF of ~960 MHz, providing 25 dB of RF-IF gain, and bandwidth of ~500 MHz. This downconverter operates on a single LO at -6 dBm which is amplified, split, then again amplified to each of the 6 channels. Integrated into each channel is a range extension switch, controlled by a TTL input and adding 20 dB attenuation. Noise figure is ~ 13.5 dB and output IP3 is ~+25 dBm. The downconverter is 2- sided, hermetically sealed and designed for rugged applications.
-
product
Loss Test Set, Return Loss Test Set
LTS1315, LTS1315R
The KD Optics LTS1315 is a combined mains / battery powered laser source and power meter designed to make attenuation testing in the field easy, reliable and most importantly, consistent. The LTS1315R incorporates return loss measurement (RLM) capability with the ability to switch very easily between dBrel and return loss.
-
product
Vector Finders with InternalAttenuators
VF-145 LA AND VF-145 LMA
The VF-145 LA and LMA models are functionally the same as the VF-145 L and LM on both electrical performance and mechanical specifications. However, the LA and LMA models include an internal PIN diode attenuator that provides up to 12 dB of attenuation (measured at 150 MHz, attenuation decrease slightly as operating frequency increases) to the incoming radio signal. This attenuation occurs after the signal is received by the unit and phase shifted for processing, but before it is placed on the coax feedline to the receiver. In addition, the PIN diode utilized will absorb short burst of RF should transceivers be keyed accidentally by the user. This feature aids in very strong signal DF operations but will not totally guarantee against system overload under very strong RF emissions.
-
product
EDFA
SPA-2-4X22-WDM EYDFA
Hangzhou Softel Optic Co., Ltd.
*Single/dual input for choice, built in optical switch for dual input, the switching power can be set by the button in the front panel or by web SNMP.*Output adjustable by buttons in the front panel or web SNMP, the range is down 4dBm*Maintenance function of one-time downward attenuation of 6dBm by buttons in the front panel or web SNMP, to facilitate the optical fiber hot-plug operation without turn off the device*Multi- ports output, can built in 1310/1490/1550WDM.*Standard RJ 45 port for remote control, we can provide output contract and web manager for choice, and also plug-in SNMP hardware can be reserved for update.*With laser key to turn on/off the laser.*With RF test function.*Adopts JDSU or Oclaro Pump laser*Led displays the working condition of the machine*Dual power hot plug power supply for choice, 90V~250V AC or -48V DC