Voltage Standards
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2H
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
PXI High Voltage Programmable Resistor Module, REDEL Connector
40-230-313-HI
-
The 40-230-313-HI (PXI) and 42-230-313-HI (PXIe) are programmable resistor modules with 2 channels which can be set between 2.5Ω and 239Ω with 1Ω resolution with maximum voltage of 1.2kV. The 40/42-230 range provides a simple solution for applications requiring voltage handling up to 1kV (9-pin D-type connector) or 1.2kV (22-pin REDEL connector).
-
Product
Standard Class AAA Solar Simulator
TriSOL TSS
-
Essential for testing virtually any material or product that is exposed to sunlight for long or short periods of time, OAI’s low-cost, Standard Solar Simulators deliver highly collimated, uniform light. Depending on configuration, output on these Solar Simulators is rated at 350W -5,000W.These Class AAA Solar Simulators feature OAI’s Advanced Uniform Beam Optics and are available with a choice of air mass filters to reproduce a wide range of solar spectra. For added flexibility, OAI’s proven lens and collimating mirror technology allows for a variety of exposure area sizes. A Class AAA Solar Simulator is an essential tool for manufacturing as well as R&D; it is indispensable in test labs, industry, and in universities. OAI Standard Solar Simulators are used in photobiology, biomedical, solar cell testing, cosmetic testing, and paints & coatings analysis. Based on 35+ years of proven UV light technology, OAI Solar Simulator Systems deliver repeatable, reliable, constant output, and measurement uniformity.
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4E
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Voltage Maintenance Program
VoltRef
-
VoltRef provides the power of automation formaintaining statistical control of the volt in yourlaboratory. This program controls a low thermalscanner and voltmeter to compare voltagestandards using the process recommended by NISTand other national laboratories.
-
Product
Oil Based Resistance Standards
-
Precision electrical resistors designed for high-accuracy resistance calibration in fluid/oil baths or in air.
-
Product
Two Pole Voltage Testers
-
Precision Mastech Enterprises Co.
Rugged, handheld electrical safety devices designed to verify the absence of voltage, check AC/DC levels (\, and test continuity via two probes.
-
Product
PXIe High Voltage Programmable Resistor Module, D-Type Connector
42-230-013-HI
-
The 40-230-013-HI (PXI) and 42-230-013-HI (PXIe) are programmable resistor modules with 4 channels which can be set between 2.5Ω and 239Ω with 1Ω resolution with maximum voltage of 1kV. The 40/42-230 range provides a simple solution for applications requiring voltage handling up to 1kV (9-pin D-type connector) or 1.2kV (22-pin REDEL connector).
-
Product
AC Voltage Proving Units
HLV-2
-
Standard Electric Works Co., Ltd
The AC Voltage Detectors and AC Voltage Testers utilized to determine if the devices under test are functionally working. They are not a calibrator and cannot be utilized for calibration.
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72T38-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
TRUE RMS High Voltage DMM
8000 HVDM
-
Standard Electric Works Co., Ltd
● True RMS measurement● For measuring solar, PV systems● Auto ranging● Bar-graph indication● Data hold function● 3000V DC Voltage measurement● 2000V AC Voltage measurement● AC mA/uA measurement● DC mA/uA measurement● Low battery indication ● Auto power off ● Low power consumption● Rugged and compact● Comply with IEC / EN 61010-1, CAT III 1000V IEC / EN 61010-1, CAT IV 600V● Comply with CAT III 1000V for the range of 0~1000V AC/DC
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1L
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 1.09 (31.00) - 4.50 (128.00) Long Travel Bead Probe
BPLT-1C-4.5
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
Product
PXIe High Voltage Programmable Resistor Module, D-Type Connector
42-230-055-HI
-
The 40-230-055-HI (PXI) and 42-230-055-HI (PXIe) are programmable resistor modules with 2 channels which can be set between 4.5Ω and 43.424MΩ with 4Ω resolution with maximum voltage of 1kV. The 40/42-230 range provides a simple solution for applications requiring voltage handling up to 1kV (9-pin D-type connector) or 1.2kV (22-pin REDEL connector).
-
Product
Standard Loggers
-
Our standard loggers can measure up to 13 parameters. Numerous configuration options allow for maximum customization for your measurement needs. In addition to our conductivity, temperature and depth sensors, many others, including third-party sensors, can be used with our recorders. Measure salinity. Measure tide and waves. Altitude & Attitude Logger.
-
Product
Standard 2.00 (57.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
F-S-R
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
Product
PXIe High Voltage Programmable Resistor Module, D-Type Connector
42-230-052-HI
-
The 40-230-052-HI (PXI) and 42-230-052-HI (PXIe) are programmable resistor modules with 2 channels which can be set between 4.5Ω and 5.762MΩ with 0.5Ω resolution with maximum voltage of 1kV. The 40/42-230 range provides a simple solution for applications requiring voltage handling up to 1kV (9-pin D-type connector) or 1.2kV (22-pin REDEL connector).
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25H-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
PXI/PXIe High Voltage Multiplexer, Single 48-Channel, 1-Pole
42-321-109-HI
Multiplexer Module
The 40-321-109-HI (PXI) and 42-321-109-HI (PXIe) are single 48-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
LXI High Voltage Switching Multiplexer Plugin Module
65-231-707-HI
Multiplexer Module
The 65-231-707-HI plug-in module is part of a scalable high voltage multiplexer platform that provides a high voltage switching solution with capability up to 7 kV. Multiplexers are created by populating the 65-200-002 scalable chassis with multiplexer plug-in modules that provide access to the Channel and Common signals on 51-pin front panel connectors.
-
Product
CDPH Standard Method for VOC Emissions
-
Underwriters Laboratories Inc.
The Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions From Indoor Sources Using Environmental Chambers, an expanded standard for what is commonly known as California Specification 01350, is one of the most widely used standards to evaluate building and interior products for low chemical emissions.
-
Product
Low Voltage Insulation Tester
AD-801
-
3 Measurement voltage ranges: 4 V, 10 V, 100 V, LCD display 3,5 digits, Autoranging, Insulation measurement up to 20 G W, LED indicator for units k W , M W and G W, Switch of choice measuring voltage 10 V and 100 V,
-
Product
3 Phase Voltage Extension To Turns Ratio Meter Rack
T-REX R
-
The Raytech three phase voltage system option T-Rex R is an optional system accessory for 3- Phase transformer ratio meter test sets designed by Raytech (i.e. TR-MARK III R). T-Rex R was designed to give Engineers and Test Technicians the ability to test the phase relationships and actual voltage ratios of transformer windings while applying three phase voltage.
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1V1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Reflectance Standards
-
Diffuse reflectance calibration standards in white or different grey levels. Traceable calibration for the wavelength range from 250 nm to 2450 nm.
-
Product
Voltage Recorders
-
Voltage Optimisation & Voltage Stablisation have become popular; the Electrocorder range of single & three phase Voltage portable Recorders are extensively used in this area as well as supply voltage analysis.
-
Product
AC DC Current and Voltage Converters
-
The DAT5023 I is an AC or DC current converter, the input current range is selectable on order from 0-5Amps, 0-10Amps, 0-20Amps, 0-25Amps, 0-30Amps, 0-40Amps, 0-50Amps, 0-60Amps. It measure the current with the use of a Hall effect transducer. There is a coil (current transformer) inside the current converter which is isolated from the current input. The cable passes through the housing of the converter and the coil and the true root mean square measurement is taken from this coil then converted to a standard industrial signal output.
-
Product
Broad-Range High Voltage Non-Contact Tester
HVNCVT-2
-
Use to check for the presence of voltage in overhead conductors or to find faults in cables.7 sensitivity ranges up to 230kV AC (240V, 4.2kV, 15kV, 25kV, 35kV, 69kV, 115kV, 230kV).Audible and visual signals indicate the presence of voltage.Water resistant.Includes durable carrying case and universal/shotgun adapter.
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39L15-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Voltage Detector / Phase Comparators
VisualPhase
-
Hachmann Innovative Elektronik
With the VisualPhase line you get a type series of handy, exact and easily operated multi-functional devices with integrated voltage detectors, phase comparator and maintenance testers. Equipped with a thorough self test to ensure reliable function, a permanently enabled interface-tester to warn against defect interfaces and the connectability to HR, MR, LR, LRM or LRP string parts every VisualPhase delivers uncompromising safety.