Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe High Voltage Multiplexer, Triple 7-Channel, 2-Pole
40-321-122-HI
The 40-321-122-HI (PXI) and 42-321-122-HI (PXIe) are triple 7-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
Standard Voltage 37 Pin D-Type Connector Blocks
The connector blocks and breakouts below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
product
PXI 2 Amp MUX, Dual 16-Channel 1-Pole
40-635-105
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
product
Passive Probes
Passive voltage probes ship standard with most oscilloscopes and provide a low cost, general purpose probing solution. Generally, these probes lack the performance of an active voltage probe but provide the ruggedness and wide dynamic range suitable for visualizing signals over a broad range of applications. Tektronix has released a new class of passive probes that redefine performance in the passive probe product category.
-
product
New Battery Resistance Tester
Hangzhou Xun Anda Electrical Co., Ltd.
maximum capacity of the battery:200AH/2000CCA(SAE)Voltage test range: 1.5-15VDCWorking voltage 1.5-15VDC,powered by the tested batterMaxim Power Consumption: around 0.5WOperating temperature: -10°C~50°C Operating humidity: 30%~90%, without condensationdisplay modes: Four different colors LED indicatorbutton: 3 buttons.Test Standard: SAE,DIN,EN,IEC,CA.
-
product
±6 kV ANSI/ESDA/JEDEC HBM Test System
HBM-TS10-A
High Power Pulse Instruments GmbH
*±6 kV Human-Body-Model (HBM) tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*Wafer, package and system level HBM testing*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*No trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT HBM current sensor for real time transient current monitoring with 1V/A output sensitivity into 50 Ω digital oscilloscope input*Integrated DUT HBM voltage sensor for real time transient voltage monitoring with 1/200V/V output sensitivity into 50 Ω digital oscilloscope input*Integrated overvoltage protection of the DUT voltage sensor, DUTcurrentsensor and DC test interface for efficient overload protection of the digital oscilloscope and SMU during high voltage HBM testing*Integrated DC test DUT switch with automatic switch control*Integrated 50 Ω precision hardware trigger output for high speed digital oscilloscopes*Fast HBM measurements, typically 0.5s per pulse including one-point DC measurement between pulses*Eficient sofware for system control and waveform data management (fully compatible with TLP measurement data)*The sofware can control automatic probers for fast measurements of complete wafers*Compact size 145 mm x 82.5 mm x 44 mm of the integrated HBM pulse generator probehead*System controller size 483 mm x 487 mm x 133 mm*High performance and high quality components*Optionally available hardware upgrades to all HPPI fully integrated HBM/HMM/TLP/VF-TLP test systems TLP-3010C, 4010C, 8010A, and 8010C
-
product
DC-DC High Performance
CPE 8th Brick Series
An eighth-brick DC-DC converter that conforms to industry standard specifications. The converter operates over an input voltage range of 36 to 75 VDC, and provides a tightly regulated output voltage with an output current rating of 30 A. The output is fully isolated from the input and the converter meets Basic Insulation requirements.
-
product
Desktop Test Interface Station
2210
TESCO’s new Desktop Test Interface Station (Catalog No. 2210) provides metering professionals with exceptional testing flexibility. The Test Interface Station is ergonomically designed for meter technicians working in a lab or a desktop, yet still rugged for field use. The Test Interface Station includes a zero insertion force (ZIF) meter socket, voltage selection, form selection, open/closed-link selection and bi-directional cabling to power a load box/test kit & connect test standard potentials. When combined with a test kit/test standard and powered via 120 VAC, the Test Interface Station creates a single position, stand-alone, meter accuracy testing device for various socket based meters (both mechanical & solid-state).
-
product
Frequency to Current Converter
DAT4540R
The Frequency to Current converter DAT4540R is a signal conditioning din rail mount converter which converts a pulse input to an analog output equal to the set range which is selectable from 0.1 Hz up to 20 KHz. The DAT4540R also provides 2 relay outputs and a transistor output. The input can be from a Tacho, TTL, PNP transistor or from any Namur standard. The DAT4540R provides a Voltage or Current output that is isolated from the power supply and input.
-
product
AC / DC Transmitter
Knick Elektronische Messgeräte GmbH & Co. KG.
For the separation and conversion of sinusoidal and non-sinusoidal alternating currents and voltages into standard signals. TRMS Education / True-RMS. Calibrated switchable versions with Weitbereichsnetzeil and high working voltage up to 3600 V AC / DC.
-
product
Surface Resistance System Kit
PRS-801RM
- Perform Point-to-Point and Resistance to Ground Measurements from 0.01 Ω to 200 Teraohms- Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω- Measures in accordance with ESD TR53, ANSI/ESD S4.1, ANSI/ESD S7.1, ANSI/ESD STM97.1 and others- Constant Test voltages 10V and 100V meeting ANSI/ESD S20.20- Operates using a Rechargeable Li-ion Battery Pack- Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)- Stores up to 999 Test Values Into Memory- Compatible with Prostat Connect 2.0 for Downloading into Excel®- Charging and Download via Standard Micro USB Cable- Includes 5lb Conductive Probes and Carrying Case- Certificate of Calibration Traceable to NIST included- 2-year Limited Warranty on Main Instrument
-
product
PXI 2 Amp Multiplexer, Single 64-Channel, 1-Pole
40-635A-001
The 40-635A-001 is a single 64-channel, 1-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
product
÷10, 500 MHz, 10 MΩ, Passive Probe (Total of 1 Per Channel)
PP008-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Mission Critical, Fault Tolerant Power Supplies
Series HSF
- Hot-swappable plug-in power supplies.- Designed to be combined in an N+1 fault-tolerant power system.- Front panel voltage adjustment trimmer for adjustment of output voltage.- Built-in forced current sharing and or-ing diodes.- May also be used independently as a multi-output power supply.- Designed to be sustainable - new models are backward compatible with existing racks.- Available in 1U and 3U sizes. Mounts in 19-, 23-, and 24-inch equipment racks.- All models include power factor correction (PFC).- Full service customized DC power distribution systems can match power supply output(s) with your load(s).- I/O connections via 24 pin connector that plugs into rack adapter. External connections are made via rack adapter.- Surface mount technology permits minimum mounting space.- Entire RA 19 racks populated with HSF power supplies can be connected in parallel, parallel-redundant or series.- HSF are CE Marked per per the LVD, EMC and RoHS 2 Directives. See applicable Declaration of Conformity.- Compliant with UL 8750, Standard for LED Equipment,- Watch video of NEBS GR-63-CORE earthquake and office vibration testing.
-
product
NI-6583, 200 MHz, 32 Single-Ended and 16 LVDS Channels, Digital I/O Adapter Module for FlexRIO
781320-01
200 MHz, 32 Single-Ended and 16 LVDS Channels, Digital I/O Adapter Module for FlexRIO—The NI-6583 is a digital I/O adapter module that, when combined with a PXI FPGA Module for FlexRIO or the Controller for FlexRIO, creates a digital instrument for interfacing with 32 single-ended and 16 low-voltage differential signaling (LVDS) digital pins. A digital I/O adapter module for FlexRIO can be used to do real-time interfacing of standard protocols and implement customized protocols. The NI-6583 can sample digital waveforms at up to 200 MHz. It includes support for selectable single-ended voltages from 1.2 to 3.3 Volts with 10 bit resolution and common LVDS voltages.
-
product
NI-6581B, 100 MHz, 54 Single-Ended-Channel, Kintex-7 FPGA-Support, Digital I/O Adapter Module for FlexRIO
783887-01
100 MHz, 54 Single-Ended-Channel, Kintex-7 FPGA-Support, Digital I/O Adapter Module for FlexRIO—The NI-6581B is a digital I/O adapter module that, when combined with a PXI FPGA Module for FlexRIO or the Controller for FlexRIO, creates a digital instrument for interfacing with 54 single-ended digital pins. A digital I/O adapter module for FlexRIO can be used to do real-time interfacing of standard protocols and implement customized protocols. The NI-6581B can operate sample digital waveforms at up to 100 MHz. It includes support for common transistor-to-transistor logic (TTL) voltage levels, or other voltage references can be sourced externally using a front panel connector.
-
product
AC Measurement Standard
5790B
The 5790B is a multi-purpose ac measurement and transfer standard designed for the most demanding calibration applications. It combines the accuracy you expect from a thermal transfer standard with the ease of use of a digital multimeter. Absolute ac voltage measurement uncertainties are as low as ± 24 ppm (one year, 23 °C ± 5 °C).
-
product
Portable Electricity Meter Testers
EE-120A-3S + EE-500V-3
The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. All types of electricity meters – mechanical or electronic, for active, reactive or apparent energy, single-phase or three-phase – can be tested with the Energy Standard. The following meter tests can be carried out with the EE Test System: Error Test, Register Test, No Load Test and Starting Current Test. Full analysis of the customer load can also be performed, if current clamps have been ordered. All test results ( maximum 3 Test Plans, 5 Manual Measurements and Customer Load Analysis) can be saved in one file. 100 saved files can be viewed on the LCD display or transferred to a PC via USB port.
-
product
NI-6585B , 200 MHz, 32 LVDS-Channel Digital I/O Adapter Module for FlexRIO
784060-01
200 MHz, 32 LVDS-Channel Digital I/O Adapter Module for FlexRIO—The NI-6585B is a digital I/O adapter module that, when combined with a PXI FPGA Module for FlexRIO, creates a digital instrument for interfacing with 32 low-voltage differential signaling (LVDS) digital pins. A digital I/O adapter module for FlexRIO can be used to do real-time interfacing of standard protocols and implement customized protocols. The NI-6585 can operate at up to 200 MHz clock rates and includes support for common LVDS voltages.
-
product
Single Phase Reference Standard Meter
Signals & Systems India Private Limited
The Single Phase Portable Reference Standard (SPRS-1102) from SANDS is a portable meter test equipment that helps to calibrate the error present in the single-phase energy meter i.e. the meter under test (MUT). The SPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, phase angle etc of the meter under test. It has an LCD display and an alphanumeric keypad to suit the user. It can be interfaced with the PC for analysis. It has the capability of storing 1000 test results.
-
product
High-Performance Multifunction Calibrator
5730A
The new 50 MHz wideband option for the 5730A High-Performance Multifunction Calibrator provides expanded wideband capabilities to self-maintaining laboratories by providing a method to calibrate the 50 MHz input of the 5790B AC Meaasurement Standard. This is accomplished by characterizing the 5730A's 50 MHz output using a precision thermal voltage converter (TVC), thus reducing uncertainties to calibrate the 5790B.
-
product
Standard Voltage Transformer
HJ / 635
Wuhan Huatian Electric Power Automation Co., Ltd.
It is mainly designed for the voltage transformer calibration standard of basic power supply and production department.
-
product
Analog Power Supply
Type NPS-2412
National RF's Type NPS-2412 analog power supply was designed to be used in communication equipment where radiated switching inverter noise from conventional “switching type” supplies is not acceptable. The power supply consists of a standard rectified transformer output driving a pair of voltage regulators and filtering networks. The 2412 offers an adjustable voltage output between 2 and 24 volts as well as a fixed voltage output of 12 volts. A maximum of 20 Watts of DC power can be supplied from the unit. As the voltage regulators dissipate power in the regulation process, the power to the load is derated accordingly, dependent on the set voltage to the load. The adjustable regulator is a standard LM-317T integrated circuit device. The fixed regulator is a standard LM 7812 device. Upon customer request, the LM 7812 device may be changed to any voltage rating within the the LM-78xx series of regulators. Contact National RF for this modification if desired.
-
product
3 Wire (Analogue) Earth Resistance Tester
4105 ER
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
product
KPG 24kV VLF Test Set
Kilovolt Prueftechnik Chemnitz GmbH
The portable cable test set KPG 24kV VLF is used for testing of medium voltage cables in accordance to the standards IEC 60502-2, CENELEC HD 620 & 621, DIN VDE 0276/620 & 621 and IEEE 400.Test is carried out with a low strain practice with VLF (very low frequency) test voltage of preferably 0.1Hz.VLF testing enables detection of damages of insulation within shortest test time.
-
product
New Battery Conductance Tester
Hangzhou Xun Anda Electrical Co., Ltd.
1. Test application: 12V/6V batteries test and 12V Starting /Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery,VRLA battery3. CCA test range: 40~2000CCA (SAE).4. Voltage test range: 1.5-15V.5. Display SOH (state of health), SOC(state of charge).6. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.7. Graphic LCD display with back light, LCD brightness adjustable.8. Multigle language operation: English, Chinese, Germany, French, Spanish. 9.internal resistance
-
product
50 Pin D-type Connectors & Cables
These standard voltage and high voltage 50 Pin D-type connectors are used for both PXI & LXI switching and simulation products for medium density applications.
-
product
DC High-Voltage Test Device
PGK 25
BAUR Prüf- und Messtechnik GmbH
Cable testing with the BAUR PGK 25. Cables must be tested in compliance with the national and international standards. This applies before the commissioning of new cable networks. The portable BAUR PGK 25 cable test device is used for DC voltage testing in low- and medium-voltage cables. It is characterised by its low weight of only 16.5 kg, by the easy operation and solid construction for onsite use.* Compact device for DC voltage testing with negative polarity* Continuously adjustable output voltage* Perfect for mobile use
-
product
Instrument Transformer
Our company has achieved a reputed niche in international market by manufacturing and exporting a great range of Instrument Transformer. Widely used in electrical, power generation and engineering sector for transforming voltage or current level, this equipment is in accordance with industry standards. Manufactured using excellent grade raw materials sourced from reputed vendor, Instrument Transformer is offered to clients in different technical specifications. We stringently test this instrument on varied standard parameters.
-
product
Battery Extra Load Units
BXL Series
BXL is an extra load unit designed to be used with DV Power’s BLU series battery testers. However, this unit is a universal add-on device. Because of that, it is compatible, as an additional load, with any other discharge/capacity tester in the market.In case when discharge current exceeds the capacity of a single BLU device, BXL can increase the discharge capacity. There are no limitations on the number of extra load units that can be connected in parallel to the main battery tester.A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way. Also, all instruments are in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.These units can be used on any type of battery string, such as lead-acid, Li-Ion, Ni-Cd, etc. They test battery strings with voltages in the range of 5,25 – 500 V DC. On the other hand, current up to 250 A can be discharged through the BXL internal structure.The instrument simulates a constant resistance load during the discharge test. Several resistances can be set for different battery nominal voltage levels. This makes BXL extremely flexible in selecting its load capabilities.
-
product
OEM Voltage Input0 to 2.5/10/25V
TGPR-0700
A voltage input data logger that is supplied uncased so that it can be built into custom applications.The TGPR-0700 can be used to record the output from a number of industry standard sensors. Common applications include pressure and windspeed monitoring.