Filter Results By:
Products
Applications
Manufacturers
2-wire
resistance measurement method.
-
product
PXI-2529, 128-Crosspoint, 2-Wire PXI Matrix Switch Module
778739-01
The PXI‑2529 is a high‐density PXI matrix switch module that you can configure as either a 4x32 or 8x16 2‑wire matrix by using different terminal block accessories. It uses electromechanical relays that offer excellent performance for high-power signals and low thermal offset for accurate measurements at low-voltage levels. The PXI‑2529 also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
product
SWB-2814, 8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781421-14
8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2814 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
product
NI TB-2644B Terminal Block for NI 2532B as 1-Wire Dual 8x32 Matrix or 2-Wire 8×32 Matrix topology With Column Protection Resistors
782385-10
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
Modbus Register Converter
Model 2390
* Converts Modbus Registers and variables for replacement Modbus devices.* Maintain existing software when upgrading Modbus systems.* Provides serial control of Modbus RTU devices from any ASCII source.* User defined Register Conversion Table supports all Modbus RTU devices.* Internal Register Conversion Tables for Watlow F4-to-EZ-ZONE and F4-to-F4T conversion.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes baud rate conversion capability.* Uses SCPI commands to load the Conversion Table and set serial settings.* Small metal case mounts on a DIN rail or on any flat panel.* 239x Table Loader Program uploads the 2390 Register Conversion Table from an Excel csv file.* 239x Serial Keyboard Program provides instant control of the 2390 and Modbus Slave Devices without writing a program.
-
product
PXI Switch - 4x8 2-Wire Matrix Module
PXI-7931
ADLINK PXI-7931 is a matrix module with 32 cross-point 2-wire relays (DPDT, 2 Form C). The default configuration of the PXI-7931 itself is a 4-group 2x4 2-wire matrix. With the termination board, TB-6231, users could flexibly choose one of the configurations: one 4x8, two 4x4, one 2x16, two 2x8 and four 2x4. Any contact of the PXI-7931 can connect to other contacts, individually or in combination. The PXI-7931 matrix module simplifies the wiring and makes it easy to change the internal connection path. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7931, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
product
Industrial Grade PCI DIO 96 Board
MS 1817
*96 digital input/output lines*Support s all PPI Modes (Mode0, Mode 1 and Mode 2)*5 V TTL/CMOS*Compatible with NI DIO Card*2-wire handshaking capability*Known power-up
-
product
Banana-Triax Adapter For 2‑Wire (Non-Kelvin) Connection
N1297A
The N1297 Series is a collection of banana-triax adapters for the Keysight B2900 Series precision source measure unit (SMU). It consists of both 2-wire as well as 4-wire connection requirements.
-
product
PXIe-2737, 256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module
782835-37
256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module—The PXIe‑2737 is a high‐density 4x64 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
product
PXI High-Density Multiplexer: 64-ch, 2-Wire, 100Vrms/1A, Reed Relays
M9101A
The M9101A, a high-density, 64-channel PXI multiplexer routes many different channels to a single point. The switches operate in a break-before-make mode that ensures no two points are connected at the same time or, if needed multiple channels can connect simultaneously. Ideal for routing multiple analog signals to a measurement device in automated test environment (ATE) or data acquisition systems. Each channel switches a high and a low for 2-wire switching up to 100Vrms, with up to 10W of power. Connection options include the durable connector block or the standard cable connections.
-
product
Speed Sensors Dust Ignition-Proof
ST420-LT / ST420-DI
Features • 2-wire, loop-powered 4-20 mA analog output • No user calibration – works right out of the box • Standard and custom measurement ranges available • Reverse-wiring protected Rugged stainless steel M18x1 housing with integral conduit attachment; FM approved, dust ignition-proof. Class II, Div I (E, F, G); NEMA 4X, IP65
-
product
Speed Sensor Intrinsically Safe
ST420
Features • 2-wire, loop-powered 4-20 mA analog output • No user calibration – works right out of the box • Standard and custom measurement ranges available • Reverse-wiring protected • Works with Electro-Sensors magnetic pulser discs / wraps Rugged stainless steel M18x1 housing; UL listed, Intrinsically Safe (IS); Class I, Div I (C, D) Class II, Div I (E, F, G)
-
product
Sensor Tester
*Connection facilities for DC 2-wire and 3-wire sensors, *Change in switching status signalled visually and acoustically, * 15 V operating voltage for sensors when using a 9 V block battery, * Switches off automatically when not in use, * Visual indicator for operating voltage, switching status and low battery
-
product
Serial Bus Buffers, Extenders, and Accelerators
The Analog Devices family of I2C solutions support hot swappable, 2-wire bidirectional bus buffers to allow I/O card insertion into a live backplane without corruption of the data and clock busses. Additional supported 2-wire buses include SMBus, PMBus, the ATCA intelligent platform management bus (IPMB), and the HDMI DDC bus. I2C/SMBus Accelerators improve bus transitions to allows multiple device connections or a longer, more capacitive interconnect, without compromising slew rates or bus performance. ADI's software-programmable and pin-selectable I2C multiplexers help resolve I2C address limitations, increase fan-in or fan-out, and integrate bus buffers and rise time accelerators for an all-in-one solution. Resistor configurable I2C address translators can be configured with over 100 unique slave addresses to allow multiple slave devices with the same address to coexist on the same bus.
-
product
T100 Toxic Gas Transmitter
The T100 is a 4-20mA 2-wire transmitter that can measure a wide range of gases. Housed in a rugged, compact metal enclosure, it is designed to be maintenance free and inherently stable.
-
product
External Temperature for 3-wire PT1000 Probe
TGP-4204
PT1000 probes are available with this logger that will record down to -200C, making them suitable for cryogenic applications. The probes are of 3-wire construction and use class A elements, making them more accurate than their 2-wire predecessors.
-
product
VXI 16-Channel, 2-Wire LVDT/RVDT Simulation
65DL1
NAI’s 65DL1 is a 16-channel, 2-wire, LVDT/RVDT Simulation Instrument on a VXI board. This single-slot, message-based board provides 16 independent, transformer-isolated, LVDT/RVDT, programmable 2-wire outputs (up to 34 V), wrap-around self-test, and an onboard programmable excitation supply.
-
product
TB-2676, Ribbon, 100 V, PXI Module Multiplexer Terminal Block
779535-01
Ribbon, 100 V, PXI Module Multiplexer Terminal Block - The TB-2676 features ribbon cable headers that help you access all channels of the PXI-2576 Multiplexer Switch Module. You can use the TB-2676 to configure the 16 banks of 4x1 2-wire multiplexers included with the PXI-2576.
-
product
PXIe-2529, 128-Crosspoint, 4x32 OR 8x16, 2-Wire PXI Matrix Switch Module
780587-29
128-Crosspoint, 2-Wire PXI Matrix Switch Module—The PXIe‑2529 is a high‐density PXI matrix switch module that you can configure as either a 4x32 or an 8x16 2‑wire matrix by using different terminal block accessories. It uses electromechanical relays that offer excellent performance for high-power signals and low thermal offset for accurate measurements at low-voltage levels. The PXIe‑2529 also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
product
NI TB-2641B Terminal Block for NI 2532B as 1-Wire 8x64 Matrix topology With Column Protection Resistors
782385-04
The TB-2641B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x128 matrix. You can directly connect the TB-2641B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2641B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
Serial Interface Device
The Serial Interface Device offers a number of options for connecting to serial hardware. You can choose from Ethernet, USB, PCI, PCIe, or ExpressCard interfaces to add up to 16 serial ports to your system. You can choose from common serial protocols, such as RS232, RS422, and RS485. The Serial Interface Device also offers various isolation, hyperthreading, and multiprocessor compatibility options. Some models also support 4- and 2-wire transceiver modes for full- and half-duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
product
Toxic Gas Sensor
Model 100
Teledyne Gas & Flame Detection
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.
-
product
Switch Mainframe
SW1001
Switch between voltmeter and battery tester while testing. 66 channels max. (2-wire) to 18 channels max. (4-terminal pair). Circuit design friendly for impedance measurements that minimize errors between channels (Effect: 0.01% f.s.*). For BT4560 100 mΩ range, R measurements, and a measurement frequency of 1 kHz. For OCV measurement, internal resistance measurement, and external potential measurement of battery cells. Measure battery modules up to 60 V DC.
-
product
NI TB-2645B Terminal Block for NI 2532B as 1-Wire Dual 16x16 Matrix or 2-Wire 16×16 Matrix Topology Without Column Protection Resistors
782385-11
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
SWB-2814, 8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781420-14
8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2814 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
product
Dining Isolation Amplifier
Knick Elektronische Messgeräte GmbH & Co. KG.
To feed and Isolation of 2-wire transmitters / sensors or SMART transmitters with HART transmission. Working voltage up to 2500 V AC / DC. Available for hazardous and non-hazardous area.
-
product
Temperature Sensors
TT420
Features • 2-wire, loop-powered 4-20mA analog output • Attachment probe, sensor, and 2-wire 4-20 mA signal conditioner • Compatible with PLCs, meters, and data acquisition systems • No user calibration • TT420Z 1/4" stainless steel probe • TT420S 1/4-28 threaded stud – screws into any 1/4-28 tap • TT420F mounts onto any flat surface • UL listed, Intrinsically Safe (IS) • Class I, (C, D) and Class II, (E, F, G)
-
product
NI TB-2645B Terminal Block for NI 2532B as 1-Wire Dual 16x16 Matrix or 2-Wire 16×16 Matrix topology With Column Protection Resistors
782385-12
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
RS232 / RS485 / RS422 Isolators/ Isolated Converters
From 3-wire to 7-wire RS232 isolators, 2-wire RS485 to 4-wire RS422 / RS485 isolators, and USB isolators to USB / RS232 / RS485 / RS422 optically-isolated converters, CommFront has all the industrial-grade optical-isolation devices to protect your assets from the unexpected. If off-the-shelf product does not provide enough security for you, we can even tailor-make the devices, which are customizable right down to the nuts and bolts.
-
product
NI TB-2643B Terminal Block for NI 2532B as 1-Wire Dual 4x64 Matrix or 2-Wire 4×64 Matrix Topology Without Column Protection Resistors
782385-07
The TB-2643B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x64 or 1-wire dual 4x64 matrix. You can directly connect the TB-2643B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2643B also provides optional isolation resistors to protect the reed relays from capacitive loads.