Four-wire
-
Product
Field-installation Type MLSS Meter (Four-Wire Transmission)
HU-200SS
-
HU-200SS connects immersion type MLSS sensor (SS-90) and measures MLSS in activated sludge. A wide range (0-2000mg/L)of SS contents can be measured with excellent reproducibility using the near-infrared radiation transmission method. Any of the calibration curves of MLSS, Clay (inorganic mud) and Kaolin may be used as standard substances of SS. If "MLSS" is selected for an activated sludge treatment tank, "Clay" for the precipitation treatment of construction sludge, or "Kaolin" for white mud, a concentration can be obtained closer to an analyzed value.
-
Product
Panel-mount Type Residual Chlorine Meter (Four-Wire Transmission)
HR-480
-
HR-480 industrial residual chlorine meter takes sequential measurements of free residual chlorine, which is an indicator used in the inspection of the anti-bacterial properties of drinking water and swimming pools.The sensor(RS-1) combined with uses a galvanic method with no drive section, making it highly maintainable, and producing stable measurements over a long period.
-
Product
Panel-mount Type Conductivity Meter (Four-Wire Transmission, 2-channel)
HE-960CW
-
HE-960CW connects conductivity sensor (ESH /FS Series) and measures conductivity and temperature in the sample water. It is ideal for the conductivity control of the purified water, pasteurized water, and water for injection that are used in the production of pharmaceuticals.And we have developed a lineup of electric conductivity sensors that can be used in conjunction, from the conventional insertion type to the flow-through type with improved cleaning and sanitary properties.
-
Product
Panel-mount Type pH Meter (Four-Wire Transmission)
HP-480
-
HP-480 connects pH sensor and measures pH and temperature in the sample water. Suitable for monitoring and control of various production processes and wastewater treatment, etc. Many types of electrodes are available to match the sample properties.
-
Product
Panel-mount Type Resistivity Meter (Four-Wire Transmission, 2-channel)
HE-960RW
-
HE-960RW connects resistivity sensor(ERF sereies) and measures resistivity and temperature in the sample water.This resistivity meter is ideal for such applications as the high-precision water monitoring employed at ultra-pure water plants used in semiconductor manufacturing.They utilize newly designed, high-precision, high-stability temperature measurement circuitry and a vastly improved temperature compensation function, an important element for measuring the resistivity of ultra-pure water.
-
Product
Field-installation Type Ammonia Nitrogen Meter(Four-Wire Transmission)
HC-200NH
-
HC-200NH is an ammonia nitrogen(NH4-N) meter using ion electrode method which is designed for aeration control in wastewater treatment.
-
Product
Octal Four-wire Multiplexer
SIM925
-
Stanford Research Systems, Inc.
The SIM925 is an eight input channel, four-wire multiplexer for low-level signal applications. Kelvin-lead measurements are supported with optional buffering of the two sense leads
-
Product
Panel-mount Type ORP Meter (Four-Wire Transmission)
HO-480
-
The HO-480 industrial ORP meter is an ORP converter for measuring the oxidation-reduction potential of all types of solvent.Being combined with a lead-free sensor, it makes measurements in a way that is kind to the environment.
-
Product
Panel-mount Type Conductivity Meter (Four-Wire Transmission, For Wide Range)
HE-960HI
-
HE-960HI is a wide-range type sanitary electric conductivity meter that can measure over a wide range from manufacturing water up to 500 mS/cm, and enables advanced concentration management through abundant outputs. It connects conductivity sensor (FES-220/310). Cleaning-in-Place (CIP) terminal management and a reduction in cleaning solutions is also achieved through accurate surface detection.And we have developed a lineup of electric conductivity sensors that can be used in conjunction, from the conventional insertion type to the flow-through type with improved cleaning and sanitary properties.
-
Product
Field-installation Type pH Meter (Four-Wire Transmission)
HP-200
-
HP-200 connects pH sensor and measures pH and temperature in the sample water. Suitable for monitoring and control of various production processes and wastewater treatment, etc. Many types of electrodes are available to match the sample properties.
-
Product
Industrial pH Meter (Four-Wire Analyzer)
HP-200-K
-
One-touch calibration function Realizes gentle measurement by combination with lead-free ORP electrode
-
Product
Field-installation Type Electric Conductivity Meter (Four-Wire Transmission, For Low-concentration)
HE-200C
-
HE-200 connects conductivity sensor (ESH/FS Series) and measures conductivity and temperature in the sample water. It is suitable for monitoring pure water/boiler water drainage recovery control and inline measurement of pharmaceutical water conductivity according to USP<645> quality guidelines.
-
Product
Field-installation Type Color Meter (Four-wire Transmission)
HU-200CL
-
HU-200CL connects flow through color detector Cl-20 and measures color and turbidity in the sample water. Suitable for monitoring purified water.
-
Product
Panel-mount Type Residual Chlorine Meter (Four-Wire Transmission, polarography method type)
HR-480P
-
Panel-mount type transmitter HR-480P connects residual chlorine sensor (RA-20) and measures residual chlorine and temperature in the sample water. Suitable for monitoring swimming pool and anti-bacterial properties of drinking water.
-
Product
Field-installation Type Residual Chlorine Meter (Four-Wire Transmission, Water flow beads)
HR-200
-
HR-200 is connected to a residual chlorine sensor (RA-20), which allows the free residual chlorine concentration to be measured with high accuracy. It is sutable for waterworks, pool water sterilization, and desalination systems. The measurement method is a three-pole polarographic method, which enables continuous monitoring of residual chlorine concentrations without using reagents. Stable measurement over a long period was realized by physical polishing cleaning using beads.
-
Product
Panel-mount Type Dissolved Oxygen Meter (Four-Wire Transmission, Membrane Type)
HD-480
-
The HD-480 industrial dissolved oxygen meter takes sequential measurements of the concentration of dissolved oxygen, which is an indicator used in the management of activated sludge tanks in waste water processing, and the quality of the water in boilers, or rivers and waterways.As there is no need to exchange the membrane of the disposable sensor included, it is easy for anyone to use.
-
Product
Four Wire Modem for SEL Mirrored-Bits
MBT 9600
-
Application specific features set the MBT9600 Four Modem apart from the conventional high speed modems. Its compact size and ease of installation make the MBT9600 an ideal, low cost alternative to conventional audio tone teleprotection systems.The circuitry is ideally suited for use over private networks such as conventional voice channels over analog microwave.
-
Product
RS-232 to RS-422/RS-485 Interface Converter
Model 9365
-
FEATURES: DIN Rail Mountable; User Selectable RS-422 or RS-485; User Selectable Two- or Four-wire RS-485; DataSpy® LCD Display; Intelligent Control of RS-485 Transmitter and Receiver; DTE/DCE Compatible; Data Rates Up to 115.2 kbp.
-
Product
Resistance Measurement
PROMET
-
High-precision micro-ohm measuring systems with adjustable DC test current for determining resistances on circuit breakers or inductive loads such as transformers, for example. The high-precision ohm meters of the PROMET series are used to determine very low electrical resistances in the µΩ range. The adjustable test current of up to 600 A in combination with a four-wire measuring method delivers measurement results which meet stringent accuracy requirements. State-of-the-art power electronics coupled with a robust design guarantee excellent reliability for use as a portable device in switching stations and industrial environments. Typical applications include determining the contact resistance of switchgear devices and determining the resistance on inductive loads such as transformers.
-
Product
Panel-mount Type pH Meter (Four-Wire Transmission, Pulse Proportional Control)
HP-480PL
-
HP-480PL industrial pH meter is a pH meter with a pulse proportional control function, which can drive a pulse pump directly.It connects pH sensor and measures pH and temperature in the sample water.As the HP-480PL has a high injection resolution per pulse, it can be used to control a pulse pump as part of a system for processing involving fine control of pH values, for example controlling the pH values of microscopic or small samples.
-
Product
PXIe-4147, 4-Channel, ±8 V, 3 A Precision PXIe Source Measure Unit
786888-01
Source Measure Unit
PXIe, 4-Channel, ±8 V, 3 A Precision PXI Source Measure Unit - The PXIe-4147 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote four-wire sensing for accurate measurements. The sample rate of the PXIe-4147 can reduce measurement times, capture transient device characteristics, and help you perform current-voltage (I-V) characterization of devices-under-test (DUTs). With a high-speed sequencing engine, you can synchronize SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4147 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
Resistance Meter
MT8-4L
-
М-module МТ8-4Л is a mezzanine module designed to measure the resistance of resistive sensors using a four-wire measurement circuit in eight channels (eight-channel digitizer). М-module МТ8-4Л is installed on the carrier of mezzanines - module НМ-М and is connected to it via a local information highway. Up to four m-modules of various types can be installed on the NM-M module. The NM-M module, together with the m-modules installed on it, forms a VXI module of size C-1 and is used to create information measuring VXI systems.
-
Product
Field-Installation Type ORP Meter (Four-Wire Transmission)
HO-200
-
HO-200 connects ORP sensor and measures ORP and temperature in the sample water. It is suitable for neutralization reaction treatment management of aeration tank, denitrification tank, etc.
-
Product
Field-installation Type Residual Chlorine Meter (Four-Wire Transmission, Rotating Type)
HR-200RT
-
HR-200RT is connected to a residual chlorine sensor (RA-30), which allows the free residual chlorine concentration to be measured with high accuracy. It is sutable for waterworks, pool water sterilization, and desalination systems. The measurement method is a three-pole polarographic method, which enables continuous monitoring of residual chlorine concentrations without using reagents.Stable measurement over a long period was realized by physical polishing cleaning using beads.
-
Product
Panel-mount Type pH Meter (Four-Wire Transmission, 4 point ararm, Time sharing Proportional Control)
HP-960FTP
-
HP-960FTP industrial pH meter is a high-end pH meter with a four-point alarm and a time sharing proportional control function.It connects pH sensor and measures pH and temperature in the sample water.It can also be linked with a cleaning device via an external input, extending its automatic operation time.Many types of electrodes are available to match the sample properties.
-
Product
Independent 24-bit Sigma-Delta Type (One for Each Channel)
TR1
-
The TR1 provides 8 channels which can be individually programmed as a Thermocouple (TC) or a Resistance Temperature Detector (RTD) measurement interface. When configured as a TC, the channel can interface with virtually all thermocouple-type NIST temperature ranges. When configured as an RTD, the channel can interface to two, three and four-wire platinum RTD sensor configurations.
-
Product
Electrical Testing
-
Innovative Testing Solutions, Inc.
Our specialty is Direct Current automotive components. We perform product validation and design verification testing on both electrical components and systems. Also, we perform warranty investigation testing and failure analysis. We have voltage capabilities to 300 volts and current capabilities to 1000 amperes. Both two-wire and four-wire resistance measurements are supported from NanoOhms to GigaOhms.
-
Product
Field-installation Type Dissolved Oxygen Meter (Four-Wire Transmission, Optical Type)
HD-200FL
-
Optical dissolved oxygen sensor with no electrolyte replacement and rugged membrane.Highly intelligent, including automatic recognition of membrane properties when replacing the sensor cap.The HD-200FL is an optical (fluorescent) dissolved oxygen meter suitable for monitoring aeration tanks used for sewage treatment, effluent treatment, and other processes. Compared to conventional membrane polarographic type sensors, there is no need for electrolyte (internal fluid) replacement or warming, up. Characteristics of optical sensors are utilized to realize unequaled, improvement in ease of maintenance and reduction in running costs. Moreover, it features enhanced user-friendliness, with sensor caps that have built-in memory and a membrane replacement notification function.
-
Product
Electronic Resistance Store
MPS2
-
The MPS2 module is a mezzanine module designed to form DC resistance in two channels with a four-wire measurement circuit. MPS2 is installed on the mezzanine carrier - the NMU module and is connected to it via a local information highway. Up to four mezzanines of various types can be installed on the NMU module. The NMU module together with the mezzanines installed on it forms a VXI module of the size C-1 and is used to create information measuring VXI systems.
-
Product
Portable Three-Phase Energy Standard
PEWM-3C
-
The three-phase energy standard PEWM-3C is used for quick on-site tests of all types of electricity meters – for active, reactive or apparent energy, two-, three- or four-wire connection. Three voltages and three currents are measured at the same time. The current can be measured either via direct connection up to 10A (class 0.1), or with three current clamps (CC) to 120A, 150A or 1000A (class 0.2).