Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
Product
ONSITE CALIBRATION SERVICE
-
Micro Precision Calibration Inc.
Benefits of Mobile Lab ServicesSaves shipping, downtime and excessive handling of expensive test instruments.Provides a controlled calibration environment at your facility.Establishes a set service date and time to work within your production schedule.Provide technicians trained in electronic and mechanical calibration.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1D
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard Voltage 37 Pin D-Type Connector Blocks for Pickering
-
The connector blocks below are suitable to use with Pickering cards and modules that utilize a standard voltage 37-pin D-type connector.
-
Product
STANAG3910 Electrica lTest And Simulation Modulefor Standard Ethernet
ANET3910-EN
-
STANAG3910 Electrical Test and Simulation module for Standard Ethernet. The ANET embedded Linux operating system gives the unique capability to run the optional PBA.pro Engine right in the box.Another option is the ANET-ADK onboard software development kit where users create run-time applications to execute right in the box. For wireless applications, an ANET compatible USB Wifi dongle is optionally available. The capability to execute Python scripts in the ANET is a standard feature. For applications with multiple ANET devices AIM offers the ADock ANET Docking Station to host up to 4 ANET modules.
-
Product
DC Standard Source
SPS-31
-
Kongter Test & Measurement Co., Limited
SPS-31 is specially designed to test analog and digital DC/AC Voltage meter, Current meter energy meter, DC voltage transducer and Current transducer. It is widely applied for test, production and inspection in research institution, national measurement institution at all levels, and meter manufacturer.
-
Product
Standard Version CODE300-32
-
CODE300-32 Standard is a software solution to demodulate, decode and analyze digital signals transmitted via radio. Our software don't requires special hrdware part for processing the signal. The audio signal can come from traditional receivers and handled with a common soud card already included on all PC and Notebook, SDR receivers, signal recorded and stored in a standard audio file, it is also possible to use audio signals from the LAN, signals in I/Q format, and digital audio signals from virtual soundcard.
-
Product
Multifunction Voltage and Current Calibrator
MC140i
-
Multifunction calibrator MC140i is ideal for calibration of voltmeters, ammeters, DMMs and panel meters. AC/DC voltage 1uV to 1000V. Current 50uA? to 1000A using test coil. Deviation control along readout. 0.0035% basic dc accuracy. 0.03% basic ac accuracy. Supplied with RS232 interfaces. UKAS/NIST Traceable
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40G
-
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
High Current Calibrator
MC151
-
MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.
-
Product
Multi Function Calibrators
-
This range of multi function calibrators are designed for accurately simulating various sensor values such as temperature, voltage and current for calibration purposes.
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-C
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
Standard In-door Forward Optical Receiver
ONR-8636
-
Hangzhou Huatai Optic Tech. Co., Ltd.
ONR-8636 with standard configuration is a type of high index and universal in-door forward optical receiver. It adopts Philip optical receiving module. End-grade adopts power-doubling module. Optical connectors and RF connector can be installed at the front panel or back panel.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1L
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Calibration Management Software
MET/CONNECT™
-
Calibration Management Software through Fluke Calibration MET/CONNECT™ Qualer is a premier asset, maintenance and calibration management system providing a pre-configured, business-in-a-box, best in class, software solution for progressive companies. Fluke Calibration’s MET/CAL® is the leading calibration automation software platform, allowing calibration labs to harness the power of thousands of automated procedures. Qualer and MET/CAL® can now be connected through Fluke Calibration's MET/CONNECT™ integration app. This enables labs to leverage the power of MET/CAL® procedures and provide the results seamlessly to Qualer as their system of record. Qualer's partnership with Fluke Calibration and MET/CONNECT™ provides a seamless way to integrate the two platforms and bring the benefits of automated calibration into the Qualer platform.
-
Product
Electrical Calibration
-
Beijing GFUVE Electronics Co.,Ltd.
Checking condition , performance , sensitivity and accuracy of any electrical device.
-
Product
3.5mm Short Open Load Thru 4-in-1 Analyzer Calibration Kit
-
Fairview Microwave’s portable calibration kits consist of two models, both with a compact, lightweight, 4-in-1 design package. These short-open-load-through (SOLT) calibration kits feature precision 3.5mm connectors, have a 26.5 GHz calibration capability, gold plated short-open-load-thru and include a handy lanyard. These SOLT calibration kits have a phase deviation of +/-2 degrees maximum and return loss of 30 dB minimum and feature an impedance level of 50 Ohms nominal. They are ideal for telecommunications, military electronics, automotive, medical, aerospace and consumer electronics industries.
-
Product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25F-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1W1S
-
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
Pressure Calibrator
HPC50
-
AMETEK Sensors, Test & Calibration
The HPC50 handheld pressure calibrator is an intrinsically safe, dual pressure calibrator with options to add an additional two external pressure or temperature modules. The HPC50 pressure calibrator combines the features you love from the HPC40 with improvements like, better battery life an improved display, an extra external module connection, and of course intrinsic safety.
-
Product
Standard Voltage 37 Pin D-Type Connectors for Pickering
-
The connectors below are suitable to use with Pickering cards and modules that utilize a standard voltage 37-pin D-type connector.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2H
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Energy Meter Calibration
GF312D1
-
Beijing GFUVE Electronics Co.,Ltd.
The instrument is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure all various of AC parameters.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3J
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
IEC Standard Burden Sets (Current)
IEC Burden Sets
-
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
Product
Force Calibration
-
Trescal provides full Force Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Force Calibration services can be delivered at your site or at our lab. Accreditations for our force calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Standard Bare Fiber Spools
-
*Custom lengths to 30km of optical fiber*Designed to fit spools in the most efficient manner*Portable for easy handling and protection*Organizes fiber while ensuring performance
-
Product
Standard Resistor Oil Bath
9400
-
Measurements International Ltd.
Measurements International’s series of fluid baths are used for the maintenance of standard resistors and shunts. The 9400 has been designed after compiling years of customer feedback on existing resistor oil baths.
-
Product
Multiproduct Calibrators
-
Its innovative design utilises the latest in cutting edge digital and analogue electronics, combined with the latest manufacturing techniques to create the world's first ultra-portable full-function calibrator.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-2
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″