Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
Product
High Precision Angular Positioning, Calibration and Geometry Inspection
LabStandard COMPACT
-
Rotary Precision Instruments UK Ltd
Designed for horizontal or vertical applications with a high accuracy angular encoder ensures sensitivity and fine positioning for metrology and precision testing.
-
Product
Standard 1.00 (28.00) - 2.30 (65.00) Non Replaceable General Purpose Probe
P2532-1
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 156Test Center (mm): 3.96Full Travel (mil): 139Full Travel (mm): 3.53Recommended Travel (mil): 93Recommended Travel (mm): 2.36Overall Length (mil): 812Overall Length (mm): 20.62Rec. Mounting Hole Size (mil): 94.5Rec. Mounting Hole Size (mm): 2.40Recommended Drill Size: #41 or 2.40 mm
-
Product
Standard 0.66 (18.70) - 4.50 (128.00) Battery Probe
CP-2LB-4
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 39Full Travel (mm): 1.00Recommended Travel (mil): 30Recommended Travel (mm): 0.75Overall Length (mil): 158Overall Length (mm): 4.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
High-Performance Multifunction Calibrator
5730A
-
The new 50 MHz wideband option for the 5730A High-Performance Multifunction Calibrator provides expanded wideband capabilities to self-maintaining laboratories by providing a method to calibrate the 50 MHz input of the 5790B AC Meaasurement Standard. This is accomplished by characterizing the 5730A's 50 MHz output using a precision thermal voltage converter (TVC), thus reducing uncertainties to calibrate the 5790B.
-
Product
PLTS Advanced Calibration
N19305B
-
PLTS N19305B extends the N19301B base product to perform advanced calibration techniques such as Automatic Fixture Removal (AFR)
-
Product
Intrinsically Safe Calibrators
-
We offer calibrators that are Intrinsically Safe and can be used in hazardous Ex areas, where explosive gases may be present. Using Ex certified calibrators makes it easier for you, as it eliminates the need for always getting hot-work permits when going on site. Our Ex calibrators are both ATEX and IECEx certified.
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
FlexVNX+ Test And Development Platform Aligned To SOSA And VITA 90 Standards
39S08VPX98Y2VAN
-
Elma’s all-new FlexVNX+ Test and Development chassis is the next generation portable test platform designed to accelerate development and test of VNX+ plug-in cards (PICs) aligned to The Open Group® SOSA™ Technical Standard and VITA 90.
-
Product
Intex Beam Gauge & Standard Contacts
-
Developed to measure both internal and external diameters and lengths, the Intex gauge's aluminium extrusion beam gives it a rigid yet lightweight quality, making it ideal for shop-floor environments. The simple release of a locking thumbscrew enables the gauge's measuring direction to be changed quickly and easily.
-
Product
European Standard for Remote Reading of Measuring Devices
M-Bus
-
M-Bus (Meter-Bus) is a European standard for remote reading of measuring devices. M-Bus is predominantly used in buildings, for example in electricity meters, gas meters, water meters or other types of consumption meters. It is also used for various sensors and actuators.
-
Product
Multi-Element Standards
-
These multi-element standards consist of multi-layer thin film coatings, one on top of the other, upto a maximum of 6 elemental coatings. It is generally recommended to have coating thicknesses < 20 µg/cm2, so as to cause negligible notable matrix effects, in particular absorption of X-rays emitted in lower deposits by those covering them.
-
Product
Deskew Calibration Source for CP030, CP030A, CP031, CP031A, AP015, CP150, CP500
DCS025
-
The DCS025 Deskew Calibration Source generates time-aligned voltage and current pulses for precise deskew of voltage and current probes.This is critical for measurements in which small propagation delay differences between probes can have a large impact on a calculated measurement, e.g., instantaneous power semiconductor device loss measurements.
-
Product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (m) 50 Ohm
CK520A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Power Calibrator And Protection Relay Test Set
CP11B
-
Calmet Smart Calibration Devices
Single phase, class 0.02 and 0.05 power quality calibrator up to 120A and 560VAC with programmable power quality parameters. It makes possible to make automatic test of electricity meters, measurement transducers, current transformers and protection relays.
-
Product
Additional Products: Standard Voltage 50 Pin D-Type Connectors
-
The connectors below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I8-4-S
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Acoustic Calibrator
CAL150
-
The Larson Davis CAL150 Sound Level Calibrator is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2L
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1F
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
CPCI-S.0 Standard Compliant Peripheral Board Controlled by a PCIe Channel Derived from the Backplane Connector P1
MIC-3820
-
MIC-3820 is a 2.5" on board SSD/HDD carrier board running at SATA Gen3 speed. A fast swap of the drive can be accomplished via a reserved thumb screw to help open a door on the front panel and eject the drive. The excellent mechanical design makes it easy to replace modules.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1T30-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Calibration Kit
WR-10
-
This precision calibration kit contains a flush short, offset piece and broadband load which allows for a full 12-term port calibration.
-
Product
C-DF Res Calibrator
-
This calibration box is used to routinely check and inspect test sets. The portable calibrator offers one Capacitance, three Tan Delta and four Resistivity values. The maximum operating voltage is 500V AC/DC.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Portable Protection Test Set and Calibrator
CMC 430
-
The CMC 430 is the preferred choice for test engineers in cases where excellent transportability is needed and three currents up to 12.5 A or six voltage outputs are sufficient. Its low weight of just 8.7 kg / 19.2 lbs, and robust design with its edge protection predisposes the device to every outdoor and indoor use.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74E
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Calibrator Module
CAP CAL
-
The purpose of CAP-CAL is to check the correctness of Tan Delta and Capacitance of TD 5000 and TDX 5000. The calibrator includes an extremely high accuracy high voltage capacitor, which comes with a certificate issued by ISA - Altanova Group lab.
-
Product
Standard & Custom Test Fixtures
-
Both standard and custom Test Fixtures from OAI enable the user to integrate the solar cell with the I -V tester. Fixture configurations range from from simple hold down devices to temperature-controlled fixtures with front and back side contact. We invite you to contact an OAI Application Engineer for help with your fixture design. With our expert guidance, you can expect maximum performance from your I -V Tester and Solar Simulator.
-
Product
Calibration Kit
FMCK1000
-
Designed to withstand daily use in high-traffic environments such as in the testing lab or on the production floor. This cost effective calibration kit provides reliable and accurate instrument tuning for all of your test and measurement requirements. Applications: VNA, Full 2-Port CAL VNA, Thru CAL VNA, Substitution CAL method Test & Measurement Lab Equipment Accessories Engineering Test and Evaluation General Purpose Test and evaluation.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T24-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02





























