Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T1-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Backflow Test Kit Repair Calibration & Certification
Meeting Water Safety regulations and standards has become a primary concern for all industries. Most municipal and state regulators demand that Backflow Prevention Testing be carried out no less than once per year and that testing devices be calibrated and if required, certified regularly.
-
product
Pressure Calibrator
30
AMETEK Sensors, Test & Calibration
The 30 Series is a wide range digital pressure calibrator that fits easily into your shirt pocket. Its internal sensors give you 0.05% of reading accuracy and resist damage from overpressure.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1C-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4S
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
product
I/Q Signal Generation for Digital Radio Standards
WinIQSIM2
R&S®WinIQSIM2™ was especially developed to easily generate digitally modulated signals on a PC. The graphical user interface allows intuitive operation by offering a convenient way to create standard-conforming waveforms for many configurable digital standards and to generate multicarrier signals and multisegment waveforms. With these capabilities, R&S®WinIQSIM2™ covers a wide range of applications.
-
product
Automatic Calibration Module
ACM2708
ACM2708 is an automatic calibration module that can be used with CMT Vector Network Analyzers operating in frequency range up to 8 GHz. The ACM 2708 is a 75 Ohm calibration module for use with native 75 Ohm VNAs (S7530) while also covering automatic calibration for 50 Ohm VNAs with the use of 50 to 75 Ohm matching pads.
-
product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1R1S
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
product
Temperature & Process Calibrators
The most sophisticated industrial equipment will not be useful unless it is calibrated. GAOTek Process Calibrators are used to adjust instruments’ accuracy, and they are the only process calibrator you will ever need to carry. They can measure temperature, pressure, voltage, resistance and frequency, and can be used during troubleshooting. Through calibration, you can ensure that any equipment performs as expected and that it can be relied on to deliver predictable and accurate results that meet quality standards. GAOTek Process Calibrators come with a USB interface which makes it easier to transfer the results to other devices which otherwise would have taken a long time to transcribe them. Our Process Calibrators are for sale to the United States, Canada and globally.
-
product
Multi-Element Standards
These multi-element standards consist of multi-layer thin film coatings, one on top of the other, upto a maximum of 6 elemental coatings. It is generally recommended to have coating thicknesses < 20 µg/cm2, so as to cause negligible notable matrix effects, in particular absorption of X-rays emitted in lower deposits by those covering them.
-
product
Calibration
During the recent years we have made scientific investigations regarding calibration procedures, which have been published and integrated in the European and International standards. The calibration of antennas and field probes in Seibersdorf is done on the reference open area test site, in three different TEM-Cells and in the fully anechoic chamber. The open area test site is one of the best in Europe. Since 1996 we are the accredited calibration laboratory according to Akkreditierung Austria 0612 for antennas and field probes.
-
product
Standard 0.88 (24.90) - 4.50 (128.00) Switch Probe
SSP-5C
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Spring Force Remark: Force at switch point: 2.36 (66)Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 150Full Travel (mm): 3.81Recommended Travel (mil): 100Recommended Travel (mm): 2.54Mechanical Life (no of cyles): 100,000Overall Length (mil): 1,210Overall Length (mm): 30.73Switch Point (mil): 25Switch Point (mm): 0.64
-
product
Electronic Calibration Module (ECal), DC-4 GHz, 2-Port
N7550A
The N7550A is part of Keysight’s family of value-line electronic calibration (ECal) modules that makes calibration of vector network analyzers fast, easy and accurate. Cut your calibration down to half the time it normally takes using a traditional mechanical cal kit. Simply connect it to your instrument and the firmware does the rest. For greater precision and higher accuracy measurements consider the N44xx and N469x family of ECal products.
-
product
Seismic Transducers Calibration System
Calibration of the seismic sensors should be conducted in the low-frequency domain, which means, that the relative method used for calibration of the vibration transducers is not applicable since it does not guarantee the required accuracy level. The problem is that the reference accelerometers have uneven AFR characteristic in the low-frequency domain. Thus, calibration of seismic transducers requires implementation of a different approach.
-
product
Disciplined Frequency Standards
2960AR and 2965AR
The 2960AR has a rubidium timebase and provides two 10MHz and one 5MHz sine wave outputs. The 2965AR has a rubidium timebase and provides one 10MHz, one 5MHz and one signal generator output. The signal generator output uses Direct Digital Synthesizer (DDS) technology and is programmable from 100Hz to 50MHz via an RS232 serial interface. Both models can be disciplined by a 1pps input signal and provide a 1pps output. The 1pps input is typically provided by the GPS Frequency output from a device like a smart GPS receiver or antenna. The Novatech GPS1 Smart Antenna is available as an accessory to provide a complete turnkey solution.
-
product
Calibration Kits
Atec’s Portable Calibration Kit, PN AHT63506-1, is used to calibrate instrumentation and transducers in engine test cells, as required per T.O. 33K6-4-3416-1 or Atec Technical Manuals.
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4D
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Calibration Services
Koehler Instrument Company, Inc.
Koehler offers a growing variety of ISO 17025 certified petroleum testing materials for your calibration and test method validation requirements. Our Technical Service Department provides calibration services conducted with traceable reference materials and standards.
-
product
Standard 0.66 (18.70) - 4.50 (128.00) Battery Probe
CP-2LB-4
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 39Full Travel (mm): 1.00Recommended Travel (mil): 30Recommended Travel (mm): 0.75Overall Length (mil): 158Overall Length (mm): 4.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3D
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.70 (20.00) - 1.30 (37.00) Non Replaceable General Purpose Probe
A-S-R
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 230Overall Length (mm): 5.84Rec. Mounting Hole Size (mil): 38Rec. Mounting Hole Size (mm): 0.97Recommended Drill Size: #62 or 0.97 mm
-
product
High-Performance Multifunction Calibrator
5730A
The new 50 MHz wideband option for the 5730A High-Performance Multifunction Calibrator provides expanded wideband capabilities to self-maintaining laboratories by providing a method to calibrate the 50 MHz input of the 5790B AC Meaasurement Standard. This is accomplished by characterizing the 5730A's 50 MHz output using a precision thermal voltage converter (TVC), thus reducing uncertainties to calibrate the 5790B.
-
product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1D
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
product
Standard Pattern Generator Board
BL-PG315-01
The MicroImage PG315 pattern generator is designed for simple size and geometry reference applications. The PG315 will overlay one of five standard patterns including a centered cross line, a centered cross hair, a centered target style symbol, a dot grid (cross dot) array, a hatch grid (crosshatch) array.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2B40
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Standard Weather Radar Test Panel
TA-3
Universal weather radar test panel with integral gyro simulator and monitor jacks. Discrete test jacks for common signals, altitude select switches and a dedicated connector for the RDS series radars. Click on picture for larger view.
-
product
Standard Capacitors
1408 Series
Ultra-high stability. The continuously improvingaccuracy of capacitor calibrations by NISTbrings a better knowledge of capacitance tostandards laboratories - provided, of course,the laboratories have adequate referencestandards. The 1408 Reference Standard Capacitors,with their high stability, are suitablefor calibration in parts in 107. The 1616 PrecisionCapacitance Bridge is highly recommendedfor accurate calibration of a wide range ofworking standards from such a reference.
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T1-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
RF Calibration Accessories
Employing good connector practice when using an RF calibrator not only avoids measurement errors and minimizes connector repeatability uncertainties but also reduces risk of damage to connectors and equipment. The 96000CONN and 9600CONN connector kits include a range of adapters and torque wrenches intended for use with the 96000 Series RF Reference Sources (9600CONN for the 96040A and 96000CONN for the 96270).The 9600CONN connector kit includes one each of 50 Ω and 75 N-Type male-female adapter for use with the 96000 Series levelling head as a “connector saver” or “sacrificial connector” to avoid risk of damage when making connections to UUT/DUT instruments.
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes





























