AC Current Clamps
wrap around conductors to measure current.
-
product
Current Transformers And Shunts
Current transformers allow the different measuring devices to provide reliable and traceable data on the trends involving consumption and production processes in electrical installations. Especially designed to be installed quickly, easily and securely, meeting the most demanding expectations of today's market, covering a wide range of primary currents as well as multiple secondary outputs, both for AC and DC measurement.
-
product
AC Voltage Test Systems
HIGHVOLT Prüftechnik Dresden GmbH
AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.
-
product
2000-6000W AC power source
CX-P2KW
Shenzhen Chuangxin Instruments Co., Ltd.
The AC power source is made by adopting microcomputer processing chip and high power device. It provides a stable pure sine wave and has voltage, over current, over temperature, overload protection. It can output 0-300V adjustable voltage, and 45-70Hz adjustable frequency as well as fixed frequency as 50 Hz or 60 Hz, 100 Hz and 200 Hz and 400 Hz. This AC power source can simulate power grid of different countries, provide a stable voltage, frequency, waveform which can be used to test and age the exprot products and provide kinds of precision tests for laboratory, measuring room, etc.
-
product
AC & DC Combined Test Set With / Without Impulse
This testing equipment is used in electrical and power industry.
-
product
Double Clamps Digital Phase Meter
SMG2000E / 375
Wuhan Huatian Electric Power Automation Co., Ltd.
A high-precision, hand-held, two-channel instrument designed to measure voltage, current and phase.
-
product
AC Resonant Test System
Yangzhou Power Electric Co., Ltd
Testing of certain apparatus requires much high voltage or current that a straight AC test system is not sufficient. Thus resonant test reactor with a variable core is needed. The main advantage of such test systems is lower input power and larger output power. The resonant test system is designed to compensate capacitance in the testing circuit precisely by tuning inductance of the test system. AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.
-
product
AC Engine Dynamometers
AC dynamometers (dynos) provide accurate and repeatable dynamometer control under stringent operating conditions for various testing applications. Whether testing small electric tools, large electric motors, off-road diesel engines, marine diesel engines or powertrain components, we have a system that’s right for you.
-
product
High Voltage, High Current Linear Amplifier
P100
The P100 is a general purpose linear amplifier having a fixed amplification of 10 times and capable of bipolar high voltage output of ±50V. Any functiongenerator or arbitrary waveform generatoror any othe signal source with amplitude up to ±10 V can be used as an input device.
-
product
Leakage Current Clamp Mete
Basic functions:AC current:20mA resolution: 0.01mA, ± (2.5%, +5)200mA resolution: 0.1mA, ±(2.5%, +5)2A resolution: 1mA, ±(2.5%, +5)60A resolution: 100mA, ±(3%, +8)AC voltage: 600V, ±(0.8%, +5)DC voltage: 600V, ±(0.8%, +5)Special functions:Auto ranging Low battery display Data hold Auto power-off Over-load protection Input impedanceDC voltage measurement: ≥10MΩ Sampling frequency: 3 times/s Maximum display: 1999 Maximum distance between clamps: 30mm General characteristics:Product colors: iron-gray and redProduct net weight: approximately 136gLCD size: 25x36mmProduct size: 183x63x29mmPower: 2x1.5V, 7#Standard accessories: packing carton and handheld bag English user's manual and battery
-
product
Clamp type AC Current Sensor/for Power Monitor
ZCT-23S
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Ultra compact size*AC 0.1A~120A*Current measurements of terminal feeder
-
product
AC /DC Withstand Voltage Tester 5KV/100mA
2672C
Shenzhen Chuangxin Instruments Co., Ltd.
*High voltage, large current, high accuracy.*Leakage current, testing time, continuous arbitrarily, well-adapted.*Synchronized display measuring value( time, voltage and current).*Can choose manual or remote control test*High voltage breakdown protection, sound and light alarm, safe and reliable *Easy operation, suitable for use in production line*DC output can test small capacitance, high-voltage silicon stack, reverse voltage of transistors
-
product
Eddy Current Testing Instruments
INSITE HT & CT
The Zetec InSite HT and InSite CT are multi-channel, multi-frequency eddy current testing instruments. They are both designed to operate at full production line speeds in tough manufacturing environments. Both the InSite HT and InSite CT are available in 2, 4, and 8 channel versions.
-
product
4A Solid State Flasher, AC Input
A915-8
NAI’s A915-8 is a 4 A, AC Input, Aircraft Warning or Navigation Light Flasher. With low RFI/EMI, zero crossover switching employed in the output circuits, this solid state, single channel unit provides long device and load life.
-
product
IEC Current Transformer Burden
• Burdens of 1A and 5A for IEC & ANSI specifications are available • 40VA, 20VA, 10VA, 7.5VA, 6.25VA, 5 VA and different combinations of these at 0.8 PF 3.75, 2.5, 1.25 & 1VA at 1.0 PF
-
product
AC VOLTAGE MEASUREMENT (AC or AC + DC TrueRMS) Digital Multimeter
1320
± 199.9mV, ± 1.999V, ± 19.99V, ± 199.9V, ± 1200V, 5 Ranges, AC VOLTAGE MEASUREMENT (AC or AC + DC TrueRMS)
-
product
AC Load Bank (Resistive/Capacitive)
K-1000 Resistive/Capacitive
Kongter Test & Measurement Co., Limited
A RCD (resistive/capacitive) generator load bank is non-linear load bank. The electronic and non-linear loads simulated by capacitive load banks are typical of the Telecommunications, Computer or Uninterruptible Power Supply (UPS) Industries.
-
product
Current Probes
Tektronix current probe solutions offer:*The broadest range of AC/DC and AC-only current probes*Measurement accuracy from uAs to 2000 A*Best-in-class bandwidth up to 120 MHz*Best-in-class current clamp sensitivity down to 1 mA*The only products with 3rd Party Safety Certification (UL, CSA, ETL)*The only products with bare wire voltage ratings*Automatic readout and scaling when used with Tektronix oscilloscopes so you don’t have to convert volts to amps or manually set the scaling
-
product
Current Differential Relay
SEL-587
Schweitzer Engineering Laboratories, Inc.
The SEL-587 Current Differential/Overcurrent Relay provides protection for any two-input apparatus, such as transformers, motors, generators, and reactors. Apply it for differential and overcurrent protection and use event reports for quick post-event analysis.
-
product
kSA ACE
The kSA Atomic Control for Epitaxy (ACE) metrology tool is a highly sensitive instrument that measures the in situ flux rate of atomic species using the principle of atomic absorption spectroscopy.
-
product
DC-Powered, AC Voltage Monitor
VAD/VQD
NAI’s VAD and VQD are DC-Powered, AC Voltage Monitors used to monitor voltage characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power-line characteristics are within pre-determined limits. These voltage monitors are ideally suited for rugged defense and industrial applications.
-
product
12-600V AC Adjustable Non-Contact Wire Tracer
5221
Peaceful Thriving Enterprise Co Ltd
This non-contact voltage tester, can be used to test the presence of AC voltage from 12V~600V, no need of metallic conduction, easy to read by visual and audio indication. Locates breaks along live, insulated wires and power cords. Adjustable sensitivity allows tracing of wires behind walls, around switches or receptacle.
-
product
Primary Current Injection Testers
Primary current injection tests are carried out during commissioning and certification of various types of switchgear and current transformers (CT), as well as during diagnostics of grounding circuits, testing circuit breakers and other devices. Primary current injection testers can also be used for determining the terminals polarity and transformation ratio of current transformers, thermal testing of electrical devices, testing automatic reclosers and sectional disconnectors.
-
product
Closed Loop Precise Hall AC/DC Current Sensor
CYHCS-LF
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for accurate measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
product
AC Load Bank (Resistive)
K-1000 Resisitive
Kongter Test & Measurement Co., Limited
The kW of a resistive load bank is “real” power in electrical terms. When a resistive AC load bank is used to test an engine generator set the engine will produce its full horsepower rating, dissipate engine exhaust gases, and produce thermal energy into the engine cooling system. The resistive load bank in fact, will completely test the engine and its various systems.
-
product
Controllable, Programmable AC Source Motorized
EAC / MT / SL
*Motor-controlled AC sources*Regulated motor-controlled AC source*Separate display for voltage and current*Regulated motor-controlled AC source*Separate display for voltage and current*Optional interfaces
-
product
Precision Voltage and Current Sources
VI-700
The VI-700 Voltage and Current Source is a versatile precision dialable or remotely programmable voltage and current source. Its three ranges provide up to 20 V full scale (200 V with the HV option), and down to 100 mV resolution; and 20 mA full scale down to 0.1mA resolution. Both voltage and current outputs are available simultaneously. The output is set by a range selector and thumbwheel switches in the LOCAL mode, or by a digital input at the rear panel. The REMOTE mode control can be a RS232 or IEEE-488 interface.
-
product
Snap-on RF Current Monitoring Probe
TBCP2-250
The TBCP2-250 is a snap-on RF current monitoring probe. The probe has a very flat response with a 3dB bandwidth of 250 MHz and is characterized over the frequency range from 30kHz to 300 MHz. Upon request, it can also be supplied with a test protocol covering the frequency range 1 kHz to 350 MHz. The aperture of the RF current monitoring probe is 32 mm. Its transfer impedance is > 12 dB Ohm in the range from 700 kHz to 300 MHz.
-
product
Current Measurement in a Compact Design
ICD-Series
Isabellenhütte Heusler GmbH & Co. KG
The ICD series is a compact system for current measurement. The ICD-A is suitable for an application in the automotive industry due to its connector, while the ICD-C is more suitable for the design industry. The shunt-based measurement provides for a high level of accuracy and temperature compensation is also incorporated through the internal signal processing. External temperature influences are thus reduced to a minimum.
-
product
Precision Current Sources
HighFinesse Precision Current Sources have been developed for experiments and quantum technologies in the areas of cold-atom and solid state physics. The linearly regulated BCS (Bipolar Current Source) and UCS (Unipolar Current Source) series deliver highly stable, low noise source currents for high precision magnetic field control. The current output is floating or is on a used defined potential. Ultrafast response to control signals and trigger functions, clear grounding, connection and signal isolation schemes make the integration of the current sources into complex experimental systems easy.