Current Probes
measure AC or AC-DC amperage without contacting conductors.
See Also: Current Sensors
-
Product
Rogowski AC Current Probe,30 MHz, 300 A
N7042A
High Current Probe
The Keysight N7042A Rogowski coil current probe measures AC currents up to 300 A, with bandwidth ranging from 9.2 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
Product
Current Probe For Multimeters
CP 1000
-
The CP 1000 current probe has been designed for use with multimeteres respectively for accurate, non-intrusive measurement of AC, DC and complex waveform currents.
-
Product
Clamp Meters
-
A clamp meter is an electrical tester that combines a basic digital multimeter with a current sensor. Clamps measure current. Probes measure voltage.
-
Product
Non-contact Sheet Resistance/resistivity Measurement Instrument With PC
NC-10 (NC-20)
-
*Easy operation and data processing by PC*No damage measurement by non-contact eddy current method*Replaceable probes by meas. range (*Second or more probe is for the option)*1 point measurement of center position*5 types of model for each measuring range*Temperature correction for silicon wafer function
-
Product
Bulk Current Monitoring Probe
MP-50
-
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
Product
Standard - 1.44 (41.00 - 4.50 (128.00) High Current Probe
HCP-13H
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Current Probe
PA-699
-
*High sensitivity: 1mA, High frequency: 1.5MHz. They are all 10 multiple calculation. Calculation is not making mistakes.*Max measuring current: +/- 40A DC / 80 Ap-p*Max sensitivity: ≧1mA*Bandwidth: DC ~ 1.5 MHz*Rising Time: 0.23 uS*Overload indicator*1V/A, 0.1V/A 2 ranges selectors*Input power switching (priority circuit) and battery available*Dispatching design, high durability
-
Product
AC Current Probe 20 mV/A, 300A, 9.2 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable
T3RC0300-UM
-
AC Current Probe 20 mV/A, 300A, 9.2 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable.
-
Product
Brute High Current Probe
P4301-1W
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
Eddy Current Data Acquisition Unit
MIZ-80iD
-
The MIZ-80iD is an all-in-one integrated eddy current instrument, probe pusher, and control system that has transformed the way eddy current data is obtained.
-
Product
AC Current Probe 50 mV/A, 120A, 34 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable
T3RC0120-UM
-
AC Current Probe 50 mV/A, 120A, 34 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable.
-
Product
Complete Power Analysis System
PK3564-PRO
-
PK3564-PRO complete Power Analysis System includes PS3550 Power Analyzer, AC charger, Quick-Start manual, deluxe voltage leads, four eFX6000 flexible current probes, SD memory card, CAS3 hard-shell carrying case, PSM-A Software, Mini Line-to-DC Converter, Bluetooth Adapter, USB Communications Cable, and 1-year deluxe warranty.
-
Product
Current Probe
PA-655
-
*Max. ±50A DCA*Resolution: ≧5mA*Bandwidth: DC~500KHz*Rise Time: 0.7us*Over Range Function*20mV/A, 200mV/A Range*Adaptor/Battery Input*Separating Design,Convenient Durable
-
Product
AC Current Probe 10 mV/A, 600A, 12 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable
T3RC0600-HF
-
AC Current Probe 10 mV/A, 600A, 12 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable.
-
Product
Current Probe
PA-659
-
*Maximum Current Value: +/- 150ADC, 100A RMS*1mA = 5mA, 50mA (switchable)*Rising Time: 0.7uS*Bandwidth: DC ~ 500kHz*Over Range Indicator*Battery, AC Power Supply Adaptor (free), dual usages
-
Product
MultiBeam System
FIB
-
An easy-to-use, out-lens type scanning electron microscope (SEM) equipped with a Schottky electron gun, as well as a new FIB column capable of large current processing (maximum ion current 90nA) installed into one chamber. JIB-4610F enables high-resolution SEM observation after high-speed cross-section milling with FIB, and high-speed analysis with a variety of analytical instruments, such as energy dispersive X-ray spectroscopy (EDS) that takes advantage of the Schottky electron gun delivering a large probe current (200nA), electron back scatter diffraction (EBSD) to perform crystallographic characterization, and cathodoluminescence (CLD). In addition, the 3D analysis function Cut & See is included in the standard configuration, allowing cross-section milling to be executed automatically at fixed intervals, while acquiring SEM images for each cross section.
-
Product
Probes, Clamp-On
EM-6981 | 9 KHz – 110 MHz
-
Current probes enable you to measure conducted current without direct connection to the circuit under test by clamping around the conductor, current carrying wire or structural member being tested.
-
Product
Clamp Meters
-
Sanwa Electric Instrument Co., Ltd
An electrical tester that combines a basic digital multimeter with a current sensor. Clamps measure current. Probes measure voltage.
-
Product
Spring Contact Probes
-
FEINMETALL offers a wide range of contact probe:ICT / FCT probes, short travel probes, double plunger probes, fine pitch probes, interface probes, wire harness probes, threaded probes, high current probes, switch probes, twist proof probes, push back probes, koaxial probes, radio frequency probes.
-
Product
30A, 100 MHz CURRENT PROBE, BNC, AC/DC, 30A rms, 50A Peak Pulse
T3CP30-100
-
30A, 100 MHz CURRENT PROBE, BNC, AC/DC, 30A rms, 50A Peak Pulse.
-
Product
CC5002X, 2 MHz, 500 A Current Oscilloscope Probe
786848-01
High Current Probe
The CC5002X, or Hioki 3275, is a clamp-on current probe that offers a wide DC to 2 MHz bandwidth and 500 A of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
Product
HPC High Current Probe
HCP-13
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Fully Automatic Non-contact Sheet Resistance Measurement System For Flatpanel Display
NC-60F/RS-1300N
-
*Global standard for non-contact measurement of ITO film, Metal thin films on flat panel*Automatic X-Y and Z (eddy current probe head) axis moving mechanism*Compatible with Loading robot for fully automatic measurementOption :*Integlate to combined system (film thickness meter, etc)*Add 4 point probe measurement unit : RT-3000
-
Product
150A, 12 MHz CURRENT PROBE, BNC, AC/DC, 150A rms, 300A Peak Pulse
T3CP150-12
-
150A, 12 MHz CURRENT PROBE, BNC, AC/DC, 150A rms, 300A Peak Pulse.
-
Product
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP030B
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Standard - 22.08 (626.00) - 220.80 (6259.60) Godzilla High Current Probe
HC500F
High Current Probe
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
2000 Amp DC / 1500 Amp AC Current Probe
DC2000
-
Our DC2000 Current Probe measures up to 2000 amps DC (as well as 1500 amps AC). Self-powered via our meter, so there are NO batteries that can run down during a measurement session.
-
Product
30A, 100MHz High Sensitivity Current Probe
CP031A
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
1000 Amp High Accuracy Current Probe
HA1000
-
The HA1000 is our most accurate current probe. The HA1000 clamp-on current probe measures from 1 to 1000 amps AC.





























