Battery Simulation
reproduce battery performance under test conditions.
See Also: Battery Simulators
-
Product
PCI Strain Gauge Simulator Card, 2-Channel, 2k
50-265-302
-
These cards simulates the operation of a range of strain gauges making them ideal for testing strain gauge meters and a wide variety of industrial control systems. They provide a simple way of replacing in house developed sensors with a low cost simulator having excellent performance that is easy to calibrate and use.
-
Product
Battery Probes
-
Offer a wide range of terminations for SMT, PTH or double-ended probes for simplified hardware mount solutions.
-
Product
Single Stream STANAG3910 Electrical Test & Simulation Module For 3U PXI Express/Compact PCI Express
ACE3910-3U-1-EN
-
Single Stream STANAG3910 Test and Simulation module – Rafale – for PXI Express/Compact PXI Express with 1 dual redundant HS/LS channel and onboard Electrical Front End (EFE).
-
Product
BIP-2 Battery Probes
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 365Overall Length (mm): 9.27
-
Product
Single Stream STANAG3910/EFEX Test And Simulation Module for PCIe
APEX3910
-
STANAG3910/EFEX Test and Simulation module for PCIe with 1 dual redundant HS/LS channel and onboardFibre Optic Front End (FOFE). Easily select between EFAbus and EFEX modes for Tranche II Eurofighter. The APEX3910 is a functional replacementfor model APE3910.
-
Product
PXI/PXIe LVDT/RVDT Simulator Module, 2-Banks
41-670-103-AABBCC
-
The 41/43-670-103 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types. It has two banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 2 channels of 5 or 6-wire or 4 channels of 4-wire.
-
Product
Synchro Simulator
SPA-CASE
-
Computer Conversions Corporation
The Synchro Simulator has two modes of operation: Static and Dynamic. The mode of operation is selected by the position of the mode switch. In the static mode, the thumbwheel switches select the output angle. In the dynamic mode, the speed and direction switches determine the rate and direction of synchro outputs. Self test circuitry continuously monitors and displays the output.
-
Product
PXI/PXIe LVDT/RVDT/Resolver Simulator Module, 2-Banks
41-670-003-AABBCC
-
The 41/43-670-003 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. It has two banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 2 channels of 5 or 6-wire or 4 channels of 4-wire.
-
Product
PXI Strain Gauge Simulator Module 2-Channel, 1K
40-265-202
-
The 40-265 is a strain gauge simulator that simulates the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. It provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance that is easy to calibrate and use.
-
Product
AC/DC Current Probe (1-Channel), 3 MHz, 50 UA
N2821A
-
As modern battery-powered devices and integrated circuits become more green and energy efficient, there is a growing need to make high-sensitivity, low-level current measurements to ensure the current consumption of these devices is in acceptable limits. The N2821A high-sensitivity probe is engineered to make high-dynamic-range, high-sensitivity measurements to meet today’s challenging current measurement needs.
-
Product
PXI RTD Simulator Module, 16 Channel, PT100
40-263-201
-
The 40-263-201 is a 16-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
Standard 2.40 (68.00) - 6.20 (176.00) Battery Probe
BIP-8
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Test Center (mil): 188Test Center (mm): 4.78Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 60Recommended Travel (mm): 1.52Overall Length (mil): 396Overall Length (mm): 10.06
-
Product
Programmable S/R Standard & Simulator
5300
-
NAI’s 5300 Synchro/Resolver Standard & Simulator is a laboratory-grade, programmable instrument. This model can be used as a true Synchro/Resolver standard for calibrating and testing Automatic Test Equipment (ATE) for Calibration/Metrology Labs, and for Engineering Design and Production Test environments. It can also be used to measure Angle Position Indicators (API) and Synchro-to-Digital converters for static or dynamic characteristics. This model also may use an external reference waveform.
-
Product
Batterie Inspektor
-
By combining the most diverse hardware and software modules, Batterie Inspektor™ delivers innovative, automated, and digitalized battery testing at every stage of manufacturing. With this flexible test platform, all modules can be adapted to their respective quality requirements. Manufacturing is simplified through a scalable and standardized framework for both new projects and upgrades.
-
Product
PXI Isolated Millivolt Thermocouple Simulator - 32 Channel
41-761-001
-
The 41-761-001 is a low voltage 32-channel output module ideal for simulating theoperation of a thermocouple, also available with 24, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
Product
PXI RTD Simulator Module 12-Channel PT1000
40-262-202
-
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
PXI/PXIe LVDT/RVDT Simulator Module, 4-Banks
41-670-101-AABBCC
-
The 41/43-670-101 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types. It has four banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 4 channels of 5 or 6-wire or 8 channels of 4-wire.
-
Product
Standard 1.17 (33.20) - 4.50 (128.00) Battery Probe
CP-2TB-8
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 88Full Travel (mm): 2.25Recommended Travel (mil): 78.7Recommended Travel (mm): 2.00Overall Length (mil): 315Overall Length (mm): 8.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
PXI/PXIe LVDT/RVDT/Resolver Simulator Module, 2-Banks
43-670-003-AABBCC
-
The 41/43-670-003 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. It has two banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal.
-
Product
PXI Strain Gauge Simulator Module 4-Channel, 1.5k
40-265-404
-
The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 4-channel, 1.5kΩ) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions.
-
Product
CP-2XX-8 Battery Probes
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 88Full Travel (mm): 2.25Recommended Travel (mil): 78.7Recommended Travel (mm): 2.00Overall Length (mil): 315Overall Length (mm): 8.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
PXI/PXIe LVDT/RVDT/Resolver Simulator Module
41-670-XYZ-AABBCC
-
The 41/43-670 range is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. Available with up to four banks, each bank is capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 4 channels of 5 or 6-wire or 8 channels of 4-wire.
-
Product
CP-4x Battery Probes
-
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
Product
Standard 0.66 (18.70) - 4.50 (128.00) Battery Probe
CP-2LB-4
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 39Full Travel (mm): 1.00Recommended Travel (mil): 30Recommended Travel (mm): 0.75Overall Length (mil): 158Overall Length (mm): 4.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
PXI Strain Gauge Simulator Module 6-Channel, 1k
40-265-206
-
The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 6-channel, 1kΩ) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions.
-
Product
PXI RTD Simulator Module, 12 Channel, PT100
40-263-301
-
The 40-263-301 is a 12-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
Radar Target Simulator
E8707A
-
Rapid developments in the autonomous vehicle and demand for greater safety features is fueling the need for more sensitive and accurate automotive radar technology being deployed in advanced driver assistance systems (ADAS). With its rich expertise in radar test technology, Keysight now offers the E8707A radar target simulator to help automotive electronics manufacturers confidently simulate radar targets in various realistic scenarios.
-
Product
Solar Array Simulator Auto-Ranging Module 0-160V, 0-10A, 1kW
MP4361A
-
The Keysight MP4361A is a 1000 W solar array simulator DC power module that simulates the output characteristics of a solar array. The MP4361A is primarily a current source with very low output capacitance. It offers fast I-V curve changes allowing you to accurately simulate the output of different solar arrays under various environmental conditions (ex. temperature, age, eclipse, spin, etc.).
-
Product
PCI Strain Gauge Simulator Card, 6-Channel, 1k
50-265-206
-
These cards simulates the operation of a range of strain gauges making them ideal for testing strain gauge meters and a wide variety of industrial control systems. They provide a simple way of replacing in house developed sensors with a low cost simulator having excellent performance that is easy to calibrate and use.
-
Product
PXI Strain Gauge Simulator Module 6-Channel, 350
40-265-016
-
The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 6-channel, 350Ω) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions.





























