Oil Breaker
-
product
Circuit Breaker Contact Resistance Meters
Vanguard Instruments Company, Inc.
The Vanguard Auto-Ohm 10 is a 10-ampere battery powered micro-ohmmeter designed for low-resistance-measuring applications such as the measurement of resistance in circuit breaker contacts, bushing contact joints, and welding joints. The unit is powered by four 3400mAh, 3.7Vdc Li-Ion rechargeable batteries. With these high capacity batteries, up to 2,900 tests per charge (10A/2 second duration) can be performed in the field.
-
product
HTMD Automatic Karl Fischer Oil Water Content Tester,Coulometric Trace Moisture Analyzer
Chongqing Assen Power Equipment Co., Ltd
HTMD Karl Fischer Analyzer has the characteristics of fast analysis speed, simple operation, high precision, and fully automatic. It’s widely used in petroleum, chemical, power, railway, pesticide, medicine, environmental protection, and other departments.
-
product
Transformer Oil BDV Tester (Single Cup)
HTJY-80B / 288
Wuhan Huatian Electric Power Automation Co., Ltd.
The tester is designed to test the power strength of all kinds of insulating oil.
-
product
Digital Circuit Breaker Analyzer
CT-7000 S3
The CT-7000 S3 is Vanguard’s fourth generation EHV circuit breaker analyzer. The CT-7000 S3 is available with 3 (part number 9021-UC) or 6 contact timing channels (part number 9100-UC). The CT-7000 S3 can fully analyze a circuit breaker’s performance by measuring the main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes. Both contact and motion analysis can be performed on all circuit breaker operations (OPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN, and OPEN CLOSE-OPEN). The CT-7000 S3’s timing window is selectable between 1 second, 10 seconds, and 20 seconds.
-
product
Oil Breakdown Voltage Tester
DTA 100 C
BAUR Prüf- und Messtechnik GmbH
Insulating oil testing with the BAUR DTA 100 C. The BAUR DTA 100 C oil tester is designed for continuous operation in the laboratory and is characterised by the combination of extraordinary features. As a high-performance device with a test voltage up to 100 kV, with clear breakdown detection and absolutely reliable measurement results even across several measurement sequences, the BAUR DTA 100 C is the leading testing device for users in the electricity and other industries and in testing institutes.
-
product
Digital Circuit Breaker Finder
ET300
Quickly, accurately, and automatically find the corresponding circuit breaker of any 120V standard outlet.Flashing arrow indicator for easy identification.Strong transmitter reaches distances up to 1,000 feet.90 - 120V operation.Microprocessor controlled for more reliable identification.Auto power-off feature saves battery life.Accessory kit available (Catalog No. 69411) includes light socket and alligator clip adapters.
-
product
Insulating Oil Testers
The main functions of electrical insulating oils are heat dissipation and reliable insulation of energised parts of electrical installations. During the normal operation, moisture and other impurities penetrate into insulating oils, leading to a deterioration of their dielectric properties. This in turn may result in catastrophic failures of critical electrical equipment.
-
product
Circuit Breaker Identifiers
188 FFF
Standard Electric Works Co., Ltd
● The 188FFF doesn't have the function of the sensitivity adjustment. If the customers need the sensitivity adjustment function, plase refer to other models.● The 188FFF is a Fuse and Fault Finder which comprises of two parts : The Receiver and the Transmitter.● The Transmitter, draws a current from the mains supply circuit to which it is connected to. The Signal● Current from the Tx is at about 10kHz. The Transmitter is powered by the mains and requires no batteries.● The 10kHz signal current generated by the Transmitter is then searched(sniffed) by the Receiver to detect the Fuse, Circuit Breaker or the faulty circuit.● The Receiver is a tuned circuit which has it's center frequency tuned to about 10kHz. The sensor is located in the tip of the Receiver.● The amplitude of the received signal is shown on a bar-graph type Leds.● The more Leds ON, the stronger the signal.
-
product
Oil Content Analyzer
OCMA-500
OCMA-500 to measure concentration of oil contained in drainage and environmental water.After injecting the water sample and solvent, all you have to do is press the start button,and the system will automatically conduct the monitoring operation from oil extraction to sample measurement and draining. With no more troublesome operations like opening/closing the drainage valve, monitoring is speeded up.In addition, the color graphic LCD and the backlit extraction tank have improved operability.
-
product
6 Contacts- Circuit Breaker Analyzer
CB14
The CB14 is a 6 contacts circuit breaker analyzer designed to perform Timing, Motion as well as Static & Dynamic Resistance Measurement (DRM) in a single test. It also includes 3 multifunction analog inputs.
-
product
Miniature Circuit Breakers
Miniature circuit breakers are applied to protect electric applications against an over current. When an electrical circuit is not protected the application can be damaged and unsafe situations may happen like fire. Mors Smitt delivers a wide range of miniature circuit breakers specially designed and tested according to railway regulations.
-
product
10 KV Oil Cell
• Operating range 2 to 12kV for a stress of 200 to 1100V/mm • Cell capacitance -65pF nominal • The cell is suitable for use with Eltel models CST- 12KSA, ACTS-5k & ACTS- 12k test sets • Measurement at 10kV at ambient temperature only
-
product
TAN-DELTA AND RESISTIVITY TEST FOR INSULATING OIL
International Biological Laboratories
TDRNT02 measures dielectric parameters like D.C. resistivity, dielectric constant and loss factor of the insulating oil of transformers, circuit breakers etc.
-
product
Oil Analyzers
We provide lab instruments, on-site oil analysis systems, and portable tools for a variety of customer needs . Our analyzers provide critical data about machinery condition and can provide an early warning of equipment failure.
-
product
Circuit Breaker Testing Equipment (SCOT Series)
SCOT M3K
SCOT M3K measures and displays CLOSE, OPEN and CLOSE-OPEN time of main contacts of 3 poles connected end to end, simultaneously.
-
product
Oil Test Cell Heater
• Dry type heater for oil test cell • Temperature setting of 20º -110ºC auto cut-off • Quick heating (RF Induction) from inside & outside
-
product
Circuit Breaker Analyzers & Timers
CAT Standard Series
Circuit breakers are being tested during manufacturing, commissioning or maintenance stages. The most basic test requires timing measurement using circuit breaker timer. Their primary role is timing and motion measurement of medium and high voltage circuit breakers. Devices from CAT Standard series have suitable application in:electric power generation,distribution system,part of the electric power transmission system,contractors testing,and industrial environments.CAT Standard series meets the requirements of an easy to use circuit breaker timer and analyzer with an attractive price. Furthermore, they are portable and lightweight (weighs only up to 7 kg). Finally, the plastic case is unbreakable and has IP67 protective rating when the lid is closed.CAT Standard series includes five models:Three circuit breaker timers – CAT03, CAT31, and CAT61Two circuit breaker analyzers – CAT34 and CAT64CAT03 is a basic model intended only for timing measurement of main contact operations on the circuit breaker with one break per phase. Unlike CAT03, CAT31 has the possibility of circuit breaker operation initiation, coil current measurement, and auxiliary contact timing measurement. CAT61 differs in comparison to CAT31 by its ability to measure up to two breaks per phase.CAT34 and CAT64 are more advanced compared to CAT31 and CAT61, respectively, since they have additional analog channels. Also, they have the possibility of a travel curve recording.A user can download the test results to a USB memory stick or save it to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Optional thermal printer prints test results in tabular and graphical form on 80 mm (3.15 inch) paper rolls. CAT Standard series instruments are compatible with DV-Win software. It provides full control of all CAT functions from a PC, as well as acquisition and analysis of test results.
-
product
Circuit Breakers for Panelboard and Controlboard
Mitsubishi Electric Automation, Inc
Series of MCCB and ELCB that provide maximum protection in a small frame size. A complete product offering for equipment control cabinets and distribution panels.
-
product
Transforming Analog Circuit Breaker Testers
MAC-21
The MAC-21 uses proven microprocessor and A/D converter technology to provide real-time waveform analysis. This ensures accurate true-RMS readings of current pulses, even with DC offset and distortion, which are typical in primary injection testing. Intelligent threshold algorithms provide accurate trip time measurement. Integration of measurement and control functions allow advanced features such as preset on times, auto ranging, and optional printer or computer interface.
-
product
Oil Purifier
Weshine Electric Manufacturing Co., Ltd
Weshine represent the absolute best in the field of transformer oil regeneration and corrosive sulfur removal. Several new features developed inhouse by our research and development department result in the state-of-the-art transformer oil regeneration equipment. Supplemented by our unique corrosive sulfur mitigation process integrated directly into the regeneration process.
-
product
Oil Break Down Voltage Test Set
This set is widely used in industries to test the load bearing capacity of insulating oil or liquid.
-
product
Insulating Oil Dielectric Loss Tester
HTYJS-H / 275
Wuhan Huatian Electric Power Automation Co., Ltd.
Used for measuring dielectric loss and resistivity of insulating oil.
-
product
Oil In Water/Soil Analyzer
InfraCal 2 TRANS-SP
The InfraCal 2 TRANS-SP is recommended for measuring oil in water, TPH in soil or FOG in wastewater concentration levels using the traditional EPA methods 413.2 and 418.1 or ASTM method D7066-04 and Freon-113, hydrocarbon-free grade of perchloroethylene, AK-225, S-316 or other spectroscopic infrared transparent solvent as the extracting solvent. Since the extract is deposited into a 10 mm quartz cuvette cell with Teflon stopper, light end volatile components are retained for measurement. Accurate down to 0.1 ppm.
-
product
Insulation Oil BDV Tester
Wuhan Fanke Transformer Manufacture Co., LTD
Insulation Oil BDV Tester
-
product
Circuit Breaker Testing Equipment
HISAC Ultima
HISAC Ultima – new generation Circuit Breaker Dynamic Test Set from SCOPE …. The ultimate solution for testing Circuit Breakers of all types. HISAC Ultima is the most complete analyser for checking the dynamic performance of CBs in live EHV switchyards upto 765 kV. HISAC Ultima can carry out Dynamic Contact Resistance Measurement on SIX breaks of THREE poles in one operation thereby significantly reducing stress on CB & testing downtime.
-
product
Oil Trace Moisture Tester
Weshine Electric Manufacturing Co., Ltd
WESHINE has developed Karl Fischer Titrator(KF Titrator) introduces the solid performance, simple operation and space saving design of the Compact KF Coulometers. Accurate results from 1 ppm to 5% water. Up to 4 shortcuts per user + 5 analysis methods.
-
product
Circuit Breaker Operational Analyzer
CBScan
CBScan is a compact and portable circuit breaker analyzer. It has limited number of channels as compared to AutoScan, but is ideal for basic shop-floor and on-site testing requirements. This analyzer has complete functionality of AutoScan. However, to ensure portability, an external laptop is required to run the test software.
-
product
Automatic Oil Tan Delta & Resistivity Kit
MOTR
The Motwane Manufacturing Company
Motwane's MOTR is multifunctional automatic test kit designed for accurate measurement of the Dielectric Constant, TanDelta, Resistivity & capacitance of transformer oil & other electrical insulating liquids. It has preprogrammed test sequences as per various International standards along with customized test sequences as per user requirements. Internal memory for 250 tests provided with PC interface & report generation facility. Inbuilt thermal printer for onsite results. Test cell is designed as per IEC247 with calibrator for onsite calibration of kit.
-
product
First Trip Testing of Circuit Breakers
Significance of Circuit Breaker "First Trip Time"A circuit breaker may not be called upon to operate and clear a fault for years, but when a fault occurs, it is expected to operate within it's published time-current characteristics. Unfortunately, frequently this does not happen... environmental contaminants, hardened grease, vibration and other factors can adversely affect the operating time of the circuit breaker.
-
product
Oil Tan Delta Tester / Tester System