Shielding
Protects against or confines electromagnetic or ionizing radiation.
See Also: Shielding Effectiveness
-
Product
Analog RF Slot Downconverter: 2000-2400 MHz Input
Model 8111-005
-
The Bandit® Model 8111 provides a series of high-performance, stand-alone analog RF slot downconverter modules. Packaged in a small, shielded enclosure with connectors for easy integration into RF systems, the modules offer programmable gain, high dynamic range and a low noise figure.
-
Product
Car-to-X Signal Strength Emulator
-
Qosmotec Software Solutions GmbH
QPER-C2X is a special adaptation of the signal strength emulator QPER, designed for mobile and Vehicular Ad-hoc Networks (MANet and VANet). Every radio devices in such an infrastructure-less network acts as a sender, receiver, and forwarder (router). Therefore, the ports of the QPER-C2X hardware are fully connected with each other by dynamically controllable attenuators. The system is fully designed for frequencies up to 6 GHz, since wireless communication for Intelligent Transport Systems (ITS) is based on the WLAN standard IEE 802.11p from 5.850 MHz to 5.925 MHz. The connected ITS stations can be either on-board units, as they are built into cars, or road side units that are used by road infrastructure (traffic lights, road work area delimiters, velocity signs). For tests in the lab, radio modules of such ITS stations are each kept in a shielding box that prevents any unwanted radiation over the air.
-
Product
10 Ft Shielded Cable For 5xxx/35xx Products (68 Pin)
GT95028
-
10 ft shielded cable for 5xxx/35xx products (68 Pin)
-
Product
Shield
Arduino MKR IMU Shield
-
The MKR IMU Shield is based on the BNO055 absolute orientation sensor from Bosch Sensortec GmbH which integrates a triaxial 14-bit accelerometer, a triaxial 16-bit gyroscope with a range of ±2000 degrees per second and a triaxial geomagnetic sensor with a 32-bit microcontroller running the BSX3.0 FusionLib software. The sensor features three-dimensional acceleration, yaw rate and magnetic field strength data each in 3 perpendicular axes.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
Product
BNC-2120, 68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block
777960-01
Terminal Block
68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block - The BNC-2120 can be used with various NI multifunction I/O and analog output devices. The BNC-2120 simplifies the connection of analog signals, some digital signals, and two user-defined connections to the data acquisition device while maintaining the integrity of your measurements with a shielded enclosure. It also features a function generator, quadrature encoder, and cold junction compensation for thermocouple measurements. The BNC-2120 includes a DIN Rail and a desktop mount option.
-
Product
Component Test Fixture For N1413 With B2980 Series
N1428A
Test Fixture
The N1428A is designed to operate specifically with the B2985B / 87B electrometer / high resistance meter. It is provided with two component modules, which are used to hold SMD, lead, and various types of devices. Electrical noise effects are reduced by the employment of a shielded case. A built-in interlock circuit enables safe high-voltage measurements. The N1413A high resistance meter fixture adapter is also required to connect the N1428A to the B2985B / 87B.
-
Product
Test Receiver
KH3932
-
Beijing KeHuan Century EMC Technology Co,.LTD
The KH3932 EM1 test receiver is a fully automatic test receiver and the main tool for EM1 testing. The frequency range of the KH3932 receiver is from 9kHz to 300MHz. Equipped with a power absorption clamp, it can meet the power line disturbance power test. After the artificial power network is configured, the power terminal disturbance voltage test can be carried out. The machine has fast test speed and maneuverability. Strong, stable performance, convenient test data processing and other advantages. The KH3932 receiver uses the USB interface to exchange data with the computer, which makes the transmission speed fast and the bit error rate low. Connect to the computer for testing and use the operating environment familiar to the operator to improve work efficiency.The equipped operating software saves the data of a variety of external equipment, and supports plug and play a variety of external test equipment. The software and hardware are developed by our company. The whole machine uses a fully enclosed structure, and the chassis uses highly conductive materials with good shielding effects. Due to the use of specific technologies and processes, the problem of its own resistance is fundamentally solved. The measurement results are in the international general report format, which can be saved in the computer's hard disk or transmitted through the network, printed out directly, and saved using a USB storage device. The report is rich in content and can be printed directly according to user needs without additional editing.The measurement receiver complies with the requirements of the national standard GBT6113.101 and the international standard CISPR16-1.
-
Product
Drum Core Inductors
-
Drum core inductors are so named as the conductor (round magnet wire) is wound directly onto the ferrite core which is shaped like a drum or spool. The wire is then connected to the core, a plastic base or metal lead frame to form the surface mount termination. Drum core inductors come in unshielded (high saturation current but potentially more EMI) and shielded constructions (lower saturation current but closed magnetic path for lower EMI). The shielded constructions use either a second ferrite core or a magnetic resin epoxy to create the magnetic shield.
-
Product
Log Periodic Antennas
-
A.H. Systems' offers 13 Log Periodic Antennas. Each antenna is lightweight, compact, rugged and has been manufactured to ensure maximum gain, low VSWR and high power handling capabilities. Whether testing inside a shielded enclosure or outdoors, the antennas will display efficient performance characteristics through the broad frequency range of 80 MHz to 7GHz.
-
Product
Rack Mountable RF Shielded Test Enclosures
-
Rack Mountable RF Shielded Test Enclosures by Ramsey Test, Inc
-
Product
G6x - 9 Module Solution
-
This 9 Module Solution provides versatility in the same small footprint as the G6. This high-density Interconnect can simultaneously engage up to 1,920 signal contacts. The ability to add 3 iCon modules into the interface design provides up to 25% more I/O. The ITA has a unique, removable EMI shielded cover which allows easy access to modules and contacts.
-
Product
ELT STALKER Vector-finder
VF-121
-
The Vector-Finder Types VF-121 and VF 121A are unique in the Vector-finder series of direction finding antennas. They incorporate a proven design, electro statically shielded loop sensing element with modern solid state low noise analog and digital technology to allow detection and location of aircraft band signals. Both the VF-121 and the VF 121A incorporate a unique digital modulator which allows the user to more easily home-in on unmodulated carriers. Such cases occur at airports when transmitter may be accidentally keyed on during aircraft overnight layovers. The VF-121 is specifically designed to be used on airport premises where signal strengths are high. To compensate for very strong signals, an integral attenuator is also incorporated to allow the user to operate the unit close-in to aircraft. The VF-121A differs in that a high gain, low-noise preamplifier is utilized with the sensing element in order to hunt signals that may be weak or at a distance. The unit is ideally suited for the location of ELT transmitters in the field. Both units are tunable over the 118 MHz to 130 MHz aircraft frequencies and interface directly to the user’s aircraft band receiver or transceiver via the antenna jack. With the antenna system connected to the receiver, the user will hear the desired signal. If the signal is unmodulated, the digital modulator will generate a tone on the carrier. When the handheld unit is rotated about, an audible null on the received signal or the generated tone will be heard. This null aligns with the axis of the equipment case and represents the direction of the received signal. This direction may be read from the black dial compass mounted on the top of the enclosure. As the response is bi-directional, triangulation may be used to determine the true bearing when the true direction is not known.
-
Product
Autoinjector Testing System
-
Instron’s Autoinjector Testing System is designed to perform full functionality testing on a wide variety of drug delivery devices, including safety syringes and both needle shield and button-activated formats. Developed in collaboration with pharmaceutical manufacturers and CDMOs, the system captures essential performance requirements such as activation force, injection time, dose accuracy, needle depth, and click detection. It supports compliance with international standards like ISO 11608 and can be configured for integration with collaborative robots to enhance automation and throughput.
-
Product
Relay Buddy PRO Test Kit
191
-
Relay Buddy is a quick go / no-go tester for the most common automotive relays. With the included adapters, Relay Buddy now tests 5 different relay types and also tests shielded relays. Relay Buddy provides you with an indication of the general health and functioning of the relay switch contacts and coil. It will check the control side of the relay by applying a signal to the relay coil while it checks for proper functioning of the relay contacts. Relay Buddy operates the relay several times during each test session as it watches for consistency in every cycle. Relay Buddy will fail the relay and light the RED LED if any one of the cycles proves unsuccessful during the test session.
-
Product
3U Enclosure with 32-bit Backplane, CompactPCI Redundant Power Supply
cPCIS-1202
Backplane
- Dual 3U CompactPCI® systems, each with five peripheral slots and one system slot- 1/1 250 W CompactPCI® Power supplies- Suitable for both rack-mount and desktop applications- Comprehensive EMC shielding- Optional rear I/O configuration (cPCI 50mm depth RTMs)
-
Product
L.V.D.T Products
-
Columbia Research Laboratories
Columbia's L.V.D.T.'s are designed for the most demanding high temperature military and industrial applications where maximum life under adverse conditions is required. The corrosion resistant stainless steel housing provides effective shielding to contain the magnetic flux within the transformer, as well as providing protection against external magnetic fields. Conservative design permits the use of these transducers well beyond their specific linear range with minimum loss of accuracy.
-
Product
SH68-68-EPM Shielded Cable, 68 D-Type to 68 D-Type, 0.35m
199006-0R35
Multifunction Cable
SH68-68-EPM Shielded Cable, 68 D-Type to 68 D-Type, 0.35m
-
Product
PXI Remote Control Interface Module
41-924-001
Interface
The kit is supplied with a PCIe card which can plug into any PC PCIe slot, this PXI module for insertion into Slot 1 of a PXI chassis and 3m lead to connect the two parts together. The interface uses a single lane PCIe connection from the PC to provide a software transparent link from the PC PCIe backplane to the PXI backplane. The supplied 3m shielded lead ensures the system has robust operation and an adequate separation distance between the PC and the PXI chassis.
-
Product
Antenna, Loop Sensor
EM-6873 | 20 Hz – 100 KHz
-
The EM-6873 Loop Sensor Antenna uses passive circuits to transform magnetic field components between 20 Hz – 100 kHz to an equivalent open circuit two-terminal voltage on the receiving instrument. Use of the conversion Factor Chart, supplied with each antenna, will yield the strength of the magnetic induction field referenced to a uniform field. The loop is electrostatically shielded and therefore is sensitive only to the magnetic component (B-field) of the electromagnetic fields.
-
Product
Shield Box
-
Anritsu's Service Testers and accessories enable OEM aftermarket service and authorized repair centers to troubleshoot and repair mobile phones and data devices quickly and economically. A full range of accessories are available including shield boxes and automation software to provide scalable test capability to the industry.
-
Product
IP67 Gigabit Ethernet, Shielded X-Code M12 Male to RJ45 (Straight), 1M for FieldDAQ
785944-01
Ethernet Cable
IP67 Gigabit Ethernet, Shielded X-Code M12 Male to RJ45 (Straight), 1M for FieldDAQ
-
Product
MMIHFWG-C, Exchangeable Unit
100263
-
With the MMIHF exchangeable unit, we offer an economical exchange system that makes it possible to keep the shielding cage and the mechanics as the basic unit when changing assemblies and thus to exchange only one cost-effective and, above all, space-saving cassette.
-
Product
ITA, G6, 6 Module, Oversized Backshell
410104732
ITA
This oversized backshell for the G6 ITA features an adjustable cable exit that can accommodate cable bundles up to 2.50". To accommodate cable exit size variations, excess shield material may be snapped off via a perforated design.This backshell also allows for an increased bend radius which is necessary for many wiring configurations including high speed due to larger wire sizes.Compatible with p/n's 310104318, 310104336, and 310104344 and the G6 ITA is backwards compatible with the G6X Receiver (310104481).
-
Product
*Micro-fluoroscopic X-ray Inspection System
Cath-X
-
The Cath-X is a bench top system employing Glenbrook’s micro-fluoroscopy technology providing highly detailed x-ray video of the critical components of the needle device. The transparent, safely shielded, view chamber permits the operator to locate the critical areas of the needle for inspection. The x-ray image can be further magnified using the electro-optical zoom feature of the Cath-X.
-
Product
RF Shielded Box
LTL B2001
-
LTL B2001 RF Test Enclosure is the streamline solution to manage your RF Testings. LTL B2001 RF shielded test enclosure can comfortably house the intermediate device on test.LTL RF Enclosures are available in aluminum and stainless steel models and come with a specialized EMI gasket which enables stable and effective RF shielding performance in all frequency bands.
-
Product
COMETEO Multi-Plate Radiation Shield
F8100
-
Newly developed meteorological screen for humidity and temperature transmitters. Passive solar radiation and weather shelter for meteo sensors.
-
Product
SH37F-P-4 37-Pin Female to Pigtail Shielded I/O Cable, 12ft
778620-04
Multifunction Cable
SH37F-P-4 37-Pin Female to Pigtail Shielded I/O Cable, 12ft
-
Product
DCDC
FC Series
-
The FC Series are ultra-low noise, high performance DC/DC converters that are packaged in low profile (0.4 inch high) cases. Essential quality performance features are designed and built-in. A high performance Pi input filter minimizes input reflected ripple, while 5-sided electrostatic shielding and tape-wound toroids, rather than pot cores, minimizeradiated EMI. Advanced circuit design techniques reduce conducted output noise in the form of current spikes, to an extremely low level.
-
Product
Electromagnetic anechoic box/Shield box/Anechoic chamber
-
The necessity of a wireless system test has risen by the spread of recent wireless telecommunication equipment as shown in cellular phone, wireless LAN, RF-ID tag and ETC (Electronic Toll Collection system). It is necessary for a wireless test to be performed in anechoic environment in which an external noise is intercepted and a radio wave does not reflect internally. An anechoic chamber (room version of a shield box) is proper facilities but needs a wide space and a huge cost. Especially, the equipment under wireless system test on the production line can not radiate any signal radio wave outside before approval. The shield box satisfies these conditions.





























