CT
1) Current Transformer 2) Computed Tomography
-
product
Primary Current Injection Test Set
T 2000
T 2000 is a portable current transformer test set which allows to perform many different measurements such as saturation, ratio and polarity tests and CT winding resistance test. Substation maintenance and commissioning test equipment, T 2000 is extremely appreciated by electrical engineers for its high accuracy and portability.
-
product
Large Current 1000A Primary Current Injection Test Set
TEST-901
Beijing GFUVE Electronics Co.,Ltd.
TEST-901 primary current injection test set adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time. Packing is used as aluminum alloy body with PC panel. TEST-901 is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current.
-
product
CT Tester, Meter Tester, Circuit Analyzer
GOLD MINER IV
Gold Miner is the first device of its type to test the electricity meter using exact, simultaneous measurements made on all primary and all secondary phases of the circuit. Perform in-service meter testing with a combined 3-phase load, or a single-phase load. Gold Miner not only displays the Meter’s accuracy, but also the overall, true accuracy resulting from the CTs + Meter combination for your entire measurement circuit.
-
product
HV CT Ratio Tester
HTCT-201 / 350
Wuhan Huatian Electric Power Automation Co., Ltd.
Specially designed and manufactured for on-line measurement of primary current and secondary current of current transformers and transformers below 35kV, variable ratio, phase difference and polarity judgment.
-
product
Clamp type AC Current Sensor/for Load Current Measurements(CT Series)
CT-23
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Compact size*AC 1A~200A*Current measurements of terminal feeder
-
product
Mini Digital Clamp Tester (CE)
M-140HC
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Easy!:Measurale Load Current at high voltage CV/CVT cables with grounding lines for shield phase.*Epoch-Making!:Can measure phase current of CVT cable just by putting CT head on to the conductors as well as CV cable just by clamping CT to the conductors in a lump.*Low Cost!:Can measure line/leakage current in the same manner as ordinary clamp meters.
-
product
Three-Phase Transformer Demagnetizer
DEM60C
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
product
Multi-Sensor Core Logger
The Geotek Multi-Sensor Core Logger (MSCL) systems enable a suite of geophysical measurements to be obtained rapidly, accurately and automatically on sediment or rock cores. The rugged nature of the equipment makes it suitable for use in either an onshore laboratory/repository environment or onboard survey and drilling vessels. All of Geotek’s core loggers accept core between 50 mm and 150 mm in diameter and up to 1.55 m in length. Geological cores and materials come in a variety of sizes therefore the MSCL and X-ray CT systems are designed for a full range of core material in a variety of liner compositions. To accommodate varying customers’ requirements (both operational and scientific), we provide a range of different core loggers and X-ray CT systems:
-
product
MXI X-Plane System
X-Plane technology provides high resolution, high magnification CT functionality anywhere on the board - without cutting the board.
-
product
High Current Comparators And Power Supplies
Designed in 3D, this custom unit fills the gap between the comparator manufacturers and the production floor. Vidac Solutions does not manufacture CT Comparators, but this unit (and others like it) are used to provide the complex high-current switching, buss-work, source current supply into an enclosure that fits into the production line and provides a safe, ergonomic and easy to use machine for the operators.
-
product
AC Current Isolated Sensor Two / Four Wire Transducer
TSCT (Average Sensing) / TFCT (TRUE RMS)
Kusam Electrical Industries Limited
• Transform Input: AC 5~400A directly into DC 4~20mA, no need external CT.• Suitable for application with high waveform distortion :(Frequency converter, Motor, SCR )• High accuracy <0.5%• High response time• High stability, easy connection.
-
product
Switch Box for CT Analyzer
CT SB2
The CT SB2 switch box is an accessory for the CT Analyzer which allows automatic testing of multi-ratio current transformers. It is connected to all taps of the current transformer and to the CT Analyzer.
-
product
Current Transformers
Rishabh Instruments Pvt. Ltd.,
Rish Nano CT is a very reliable, efficient and robust current transformer for measurement of AC current. It provides 100 mA AC output. It can be used in Circuit breakers. Earth Leakage Protection.
-
product
Transformer Analyzer
505
The UTEC 505 Transformer Analyzer is designed for testing current transformers (CT) and potential transformers (PT) without interruption of the customer’s service. This instrument measures CT admittance, CT ratio, CT primary-to-secondary phase angle and the voltage, current and phase angle of the service. With the ‘Burden CT/PT Option’, it determines the CT secondary burden capability, the regulation of the PT and its secondary burden capability and provides for CT core demagnetization.
-
product
Flexible Leakage/Line Current Tester
RLM-10+
MULTI MEASURING INSTRUMENTS Co., Ltd.
●Low-pass filter equipped, it can be cut the noise which is over 150Hz frequency.●Even Coreless Coil but Least Influence from External Magnetic Field and Residual Current●Superior Flexible CT enables Leakage Current Measurement●Backlight Function useful for measurement in the dark place
-
product
X-ray Inspection System
X-eye SF160 Series
High-performance Micro-focus Open Tube with 160kV is installed and fine defects of 1㎛ are detectable. High-resolution X-ray image can be gained with world best magnification by installing high-price Open Tube as standard.Dual CT function can be purchased adtionally, and exact location & size of defects can be detected and analyzed with this function.
-
product
Split Core Current Transformer
Beijing GFUVE Electronics Co.,Ltd.
Have a "split" in the core that allows the CTs to open and be placed around the conductor without having to disconnect the conductor or disrupt the wiring.
-
product
ANSI Metering Current Transformer Burden
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
product
CT-ALPHA
The CT-ALPHA system meets the most stringent demands in CT X-ray. With this Computed Tomography system, ProCon X-ray GmbH offers the highest possible flexibility for individual customer requirements.
-
product
Digital Clamp Tester With 80mm X 74mm CT With Bluetooth40mmφCT, ACA
MCL-800DX
MULTI MEASURING INSTRUMENTS Co., Ltd.
Next-generation leakage current clamp meter with connection, via Bluetooth, to a smartphone which displays waveforms and data.
-
product
Non-contact Io/Ior Leakage Clamp Meter
MCL-800IRV
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Safety by non-contact sensor, not touching live part directly (prevention of electric shock, short-circuit, etc.).・Easy to carry and operate, clamp CT + display part integrated type.・Measurable line current + leakage current + resistive leakage current by one unit.・Available direct voltage input at live part as ordinary.・Calculable insulation resistance value(MΩ)by voltage & current (only in case of using direct voltage input sensors)・Available measurement for 3P/4W star connection.
-
product
Power Meters
The new range of Hobut multifunction panel meters feature 96 x 96mm sizes complete with unique blue LED screen, which can be seen in direct sunlight. The range is easy to use, features user-programmable CT & VT ratios, and can be used on any single or 3 phase system with any input voltage without re-programming.
-
product
Eddy Current Testing Instruments
INSITE HT & CT
The Zetec InSite HT and InSite CT are multi-channel, multi-frequency eddy current testing instruments. They are both designed to operate at full production line speeds in tough manufacturing environments. Both the InSite HT and InSite CT are available in 2, 4, and 8 channel versions.
-
product
Multifunction Substation Test Set
STS 4000
STS 4000 is a multifunction substation maintenance & commissioning test system for current, voltage and power transformers, designed to perform primary tests requested in substations commissioning. It allows to perform accurate tests on CTs, VTs, PTs and ground grid.
-
product
Test Switches and Accessories
Test switches are designed and manufactured to allow quick and easy multi-circuit testing of switchboard relays, meters and instruments by any conventional system.These test switches and related test plugs have the features necessary for applications involving the measurement of individual currents and voltages associated with substation instrumentation and protection devices. They have been especially designed for the measurement of potential elements, current elements, and make-before-break short-circuit elements related to Current Transformer (CT) circuits.
-
product
LCD Power Meters
Accuracy ±0.1% F.S. Measuring and display ACV/ACA/Watt/Var/VA/Power Factor/Frequency/KWH/DM(Demand) Input measurement network can be selectives(1P2W/1P3W/3P3W/3P4W) CT rate/PT rate can be modified(1 to 9999) Measuring ACV/ACA total harmonic distortion(THD),up to 35th harmonic(optional) Two alarm control function (optional) Two pulse output function (optional) Digit RS-485 interface function (Optional)
-
product
X-RAY Cameras Based On CCD
XiRAY
*High resolution direct phosphor imaging, ideal for Micro CT*Ultra-low readout noise with CCD and especially the new sCMOS sensors*Crystal clear 14 bit/pixel images*Partial readout and binning modes for enhanced sensitivity and higher speed*Non-linearity over full dynamic range <2% (of full scale) to 95% of full scale*External triggering, LVTTL*Low power consumption 6 Watt with Cooling or 2W without*Antiblooming, Enhanced Statistical Extra-Mural Absorption*Radiation hardened, Support of Energy levels 7 to 100keV*Measures just 63 x 63 x 46 mm*Peltier TE Cooled with Heatsink and optional fan
-
product
Secondary Current Injection Test Trolley
SCR ELEKTRONIKS have developed SECONDARY CURRENT INJECTION TEST TROLLEY for Switchgear items, CT manufacturer and where three phase current application is called for. It is low Voltage, 3 phase Current source with control circuitry, digital read out for test current and trip time measurement. We can select different CT ranges for each phase independently and adjust the current as per the required test Current.
-
product
CT-PT-CVT Measuring
Testing object: S current transformer, normal current transformer, voltage transformer● Testing item: ratio error, phase error, impedance, admittance of the transformer, etc● Rated current:5A,1A ( Customized )● Rated voltage: 100V, 100/√3V, 100/3V, 110V, 110/√3V, 110/3V, 120V, 120/√3V, 120/3V, 220V (or other)● Measurement range: ratio error measurement range : 0.0001%-19.99% phase error measurement range : 0.01 ' -900 '● Error minimum resolution:ratio error:0.0001%; phase error:0.01 ' ● Communication function : provide RS232 serial communication port● Measurement accuracy: ±1%● Consumed power: less than 20VA● Dimension :460×380×160 mm● Weight: 12kg