product
Automatic Transformer Test System
TH2840BX
Changzhou Tonghui Electronic Co., Ltd.
■ The test speed is as high as 1000 times/s (>10kHz), without relay action time ■ Test level up to 20Vrms ■ The bias voltage is built-in ±40V/±100mA/2A ■ Up to 288 test pins (only TH2840NX) ■ Industry-friendly user experience: Linux bottom layer, built-in help file
-
product
Transformer Turns Ratio Meter
TTRM 302
SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.
-
product
Current Transformer with Open Core
TCP
Lifasa - International Capacitors, SA
The TCP series is designed for installations in operation. It has a removable core that allows its connection without interrupting the power supply.
-
product
Software For Transformer Measuring Lite
T-Base Lite
T-Base Lite is intended for users preferring simplicity over complexity of the Pro version. It is limited to the basic functions of USB interface, data import, data export, synchronization, and automatic firmware updates. Data can be exported in many popular data formats such as Excel, Word, text, .csv, .xml, Crystal reports, and .html. Measurements can be saved as archive files and imported into the database of the T-Base Pro version.
-
product
Control Cabinet for Testing Transformer in Power Test Project
XC / 595
Wuhan Huatian Electric Power Automation Co., Ltd.
Your product description goes here.
-
product
True Online UPS Systems with Inbuilt Isolation Transformer
Our software and connectivity devices incorporate all the features you need to proactively manage your systems, from basic monitoring and shutdown to predictive analysis and power management. Aplab Integration Services offer complete solutions tailored for the specific requirements of Defense Services, Telecom and Commercial markets.
-
product
Transformer Turns Ratio Meter
TTRM 102
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
product
ANSI Relaying Current Transformer Burden
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
product
Transformer Polarity Tester
PMT20030
Power Measurement Technologies Inc.
A hand held instrument for polarity identification of current, voltage and power transformers with an operable ratio range from 1:1 to greater than 5000:1.
-
product
Automatic Transformer Test System
TH2829AX
Changzhou Tonghui Electronic Co., Ltd.
*Number of Test PIN: 20*Frequency: 20Hz-200Hz, Resolution: 0.5mHz*Signal Level: 50mV-2Vms (Option 2nv-10Vms)*Test Speed: max 13ms
-
product
High-Speed Transformer Test System
DU-7211
Delta United Instrument Co., Ltd.
Inductance, Q factor, Leakage Inductance, AC Resistance, Capacitance, DC Resistance, Balance,Turn ratio, Open/Short check
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
product
Transformer & Capacitor Testers
*Quick and easy check for opens or shorts on transformers before energizing*Provides clear indications of open circuits, short connections and confirmation that the test results are OK*Tests overhead, pad-mount and other distribution transformers*Tests the primary and secondary sides of de‑energized transformers without disconnecting*Helps prevent line workers from installing a fuse on a shorted transformer*Automatic self-test feature*Magnet holds the tester in place while testing
-
product
Clamp-On / Precision / Split Core Current Transformer
Transformer Ratio (Arms) : 100A / 1AColours : Red, yellow, blueConnection : Safety Sockets for Banana Plugs ф 4mm Jaw Opening : Cable Dia 15mm max.
-
product
Transformer Ratio Meters
The TRT is based on state-of-the-art technology and uses the most advanced technique available today. The test equipment can be used to test both single-phase and three-phase transformers, both with and without tap changer in accordance with the requirements of IEC 60076-1.
-
product
Transformer Loss Measurement Systems
Measurements International Ltd.
The Transformer Loss Measuring System stands as a pivotal tool in ensuring the quality assessment of transformers. It plays a vital role in accurately measuring and evaluating the transformer’s performance by assessing both its no-load loss and load loss. Understanding these losses is essential in determining the efficiency and overall quality of the transformer, offering valuable insights for maintenance and improvement strategies.
-
product
Current Transformer Analyzer/Tester
GF1061
Beijing GFUVE Electronics Co.,Ltd.
Portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to download data or RS232 port to PC control. This model GF1061 CT PT analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE C57.13 and IEC60044 & IEC61869 standards.
-
product
Transformer DC Winding Resistance Tester
HTZZ-5A / 230
Wuhan Huatian Electric Power Automation Co., Ltd.
Applicable for transformer to submit the dc resistance testproject around group in pick up and overhaul project.
-
product
Transformer Demagnetization Tester
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
product
Current Transformer
ST-3RCT
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 20~300
-
product
Automatic Transformer Test System
TH2829AX-48
Changzhou Tonghui Electronic Co., Ltd.
Number of Test PIN: 48 ■ Frequency: 20Hz-200kHz, Resolution: 0.5mHz ■ Signal Level: 5mV-2Vrms(Option:2mV-10Vrms) ■ Test Speed: max. 13ms ■ 7-inch TFT LCD display with a resolution of 800×RGB×480
-
product
DC POWER
VARIABLE TRANSFORMER
Variable DC power supplies are AC to DC power supplies with a variable DC output. The output can be varied with a Variable Transformer (also known as variac). The Variable Transformer can be adjusted manually or with a motorized control. The AC input power can be single phase or three phases. With single phase AC input, the DC output ripple is very high (50%). With three phase AC input, the DC output ripple is low (5%). This would be a key benefit for selecting three phase AC input instead of single phase.
-
product
Transformer Rectifier Assemblies
Transformer rectifier assemblies are very useful in OEM applications when unregulated DC output is required. Input power can be single-phase or three phases. With single-phase input power, the output ripple is 50%. With three-phase input power, the output ripple is 5%. A 5% output ripple is a clear advantage. Hence, transformer rectifier assemblies with three-phase input power are more popular. Circuit breakers, fuses, voltmeters, and ammeters can be added per customer requirements. The assemblies can be an open frame or inside an indoor enclosure.
-
product
Test Automation Solution
CONFORMIQ TRANSFORMER
Conformiq Transformer shortens the path to test automation, simplifies model-based testing (MBT) adoption using existing methods, and automates manual test execution. Along with Conformiq Creator, which generates executable test cases, scripts and documentation from models, it automates and transforms test design, extending the Conformiq 360° Test Automation™ solution for complex system testing at the speed of development.
-
product
Transformer Winding Resistance Meters
RMO TW Series
The RMO-TW instrument can perform a simple, fast and reliable verification of a transformer on-load tap changer. This instrument allows measurements of a winding resistance at each tapping position of an on-load tap changer without discharging between tests. Problems with OLTC switching, such as interruption, can be detected with these measurements. The results are displayed on a backlit LCD screen.
-
product
Fully Automatic Transformer Winding Resistance Tester
Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.
-
product
Transformer Oil Acidity Testing Kit
NMC Brand Transformer Oil Acidity Testing Kit used to measure the Acidic content of Transformer Oil
-
product
Transformer Tester
Kvtester Electronics Technology Co.,Ltd
High precision instrument for measuring characteristic parameters of transformer capacity, no-load and load. The instrument is a multi-function measuring instrument, which is equivalent to the usual two kinds of test instruments: the transformer capacity tester + transformer characteristic parameter tester. The utility model can precisely measure a series of power frequency parameters of a plurality of transformers, such as the capacity, the type, the no-load current, the no-load loss, the short circuit (load) loss and the impedance voltage.
-
product
Transformer Oil Breakdown Voltage Tester
HBVT
Hention Electrical Equipment Co., Ltd.
HBVT Transformer Oil Breakdown Voltage Tester , in accordance with IEC156, is designed to check insulating oil’s dielectric strength.The test set is compact and portable, therefore suitable for field work.
-
product
Fully Automatic Transformer Oil Acidity Testing Kit
NMC offers Fully Automatic Transformer Oil Acidity Testing Kit