Transformer
transfers of electricity from one circuit to another by electro-magnetic induction.
See Also: Transformer Testers, Power Distribution, Coil
-
Product
Injection Transformer
J2100A
-
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
Product
Current Transformer
CT
-
The split-core current transformers are easily installed with the snap on design.
-
Product
Current Transformer Testers
-
Vanguard Instruments Company, Inc.
Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface
-
Product
Instrument Transformer Calibrators
CTPT 81
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
Product
Multiple Gas Transformer DGA
MULTITRANS
-
The MULTITRANS is an 8-gas on-line transformer DGA monitoring unit designed to monitor a bank of three single-phase transformers in close proximity. Based on the same core technology as the highly successful TRANSFIX the MULTITRANS measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm).
-
Product
Transformer Test System
-
Transformer testing instrument, can be used as a stand-alone device and has the highest efficiency. Can be used in power transformers, network communication transformers, etc.
-
Product
Transformer Winding Resistance Tester
KRI 9310
-
KRI 9310 adopt Kelvin four-wire testing method, which effectively eliminates the influence of the resistance of the test line on the test results. It can be able to increases the current to 10A by which can test extremely low resistance to 0.01 Ω(such as amorphous alloy, Copper-nickel, nickel-chromium-iron, iron-chromium-aluminum etc). For the tested objects with high resistance value (CT/PT), the instrument can extend the range to 20 kΩ,so the wide resistance test range enables KRI9310 can cover 80% of the power transformer products on the market and switchgear bus-bar cable etc. The power of the tester use the built-in rechargeable lithium battery that can test hundreds of transformers by one time charging.
-
Product
Solid State Active Synchro Control transformer and Solid State Resolver Control Transformer
-
Computer Conversions Corporation
The SCT Series are low cost, miniature, solid state control transformers designed for military and industrial control applications. They will directly replace conventional electromechanical control transformers & thus provide digital control to existing analog servo systems. They simultaneously accept a 3 wire synchro input (0) and a digital angle input (0), and provide an ouput which is the sine of the difference between these two input angles (A sin wt sin (0-0) ("wt" is the synchro excitation frequency).
-
Product
Transformer Winding Resistance Meter
XWRM-10
-
The Motwane Manufacturing Company
The Motwane make XWRM-10 is a dual channel 10A rated, Transformer Winding Resistance Meter designed and developed aftere xtensive research on challenges and requirements of testing of various Transformer winding resistance. The instrument has One Current channel and two Resistance Channels. The instrument provides a large open circuit voltage of 42Volts, for fast charging of the highly inductive windings of transformers, to provide stable resistance values in minimum time. The XWRM-10 is intended to replace complex bridge set up with a single compact instrumentThe XWRM-10 is based on 4-wire measurement methodto measure low resistance accurately. The instrument iswell protected against inductive kickbacks offered by theinductive windings and gives stable reading on varioustypes of transformers.
-
Product
Split type AC Current Transformer
CTF-100T
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Wire stopper is equipped for the slipping protection.*The special connector is not necessary as the output terminals are provided.*Open circuit protection and nonflammable plastic material.
-
Product
Burn Down Transformer
ATG 2
-
Cable fault location with the BAUR ATG 2. The ATG 2 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 2300 VA stray field transformer delivers a maximum voltage of 10 kV and is housed in a fully enclosed 19" housing.* Portable device for changing the fault resistance* Useful for cables that are difficult to access* Proven methods for complicated faults* Independent current and voltage control on each burning level
-
Product
Test Equipment for Instrument Transformer
-
is desirable for measuring ratio errors and phase angles of low current (voltage) transformers used in electric devices, such as watt hour meters, smart meters, digital current meters, and transducers, etc.
-
Product
Transformer Performance Tester
JYW6100
-
JYW6100 Transformer No-loads and On-loads tester power factor tester is suitable for loss testing of low power factory transformer such as amorphous alloy transformer, with high precision and data loc
-
Product
Transformer Testing Panel
VTTP
-
Capable to Test Up to 25 MVA (Other Ranges are Available On Request). Useful for No Load Test (O.C.), Load Test (S.C.), DVDF Test HV Test of Transformer. Mains indication by R,Y,B indication Lamp. Over voltage, over current protection.
-
Product
Power Transformer Automatic Test Device
XD71
-
Hangzhou Xihu Electronic Institute
The device is used for power transformer power outage routine test items to do automated testing.Which is characterized by dielectric loss, insulation resistance, DC resistance, tap-changer switching characteristics, short circuit impedance and variable ratio of six test items are concentrated in an instrument,so that the instrument function, test power and test lead height fusion.Field test, just start wiring once, at the end of unplugging wiring once,the middle process by the test personnel in the computer terminal to send command control,the test system automatically completes all or part of the above test items.
-
Product
Automatic Transformer Test System
TH2829AX
-
Changzhou Tonghui Electronic Co., Ltd.
*Number of Test PIN: 20*Frequency: 20Hz-200Hz, Resolution: 0.5mHz*Signal Level: 50mV-2Vms (Option 2nv-10Vms)*Test Speed: max 13ms
-
Product
Transformer Tester
-
Kvtester Electronics Technology Co.,Ltd
High precision instrument for measuring characteristic parameters of transformer capacity, no-load and load. The instrument is a multi-function measuring instrument, which is equivalent to the usual two kinds of test instruments: the transformer capacity tester + transformer characteristic parameter tester. The utility model can precisely measure a series of power frequency parameters of a plurality of transformers, such as the capacity, the type, the no-load current, the no-load loss, the short circuit (load) loss and the impedance voltage.
-
Product
Transformer Insulation Testing
-
The primary test methods used to assess the condition of the active insulation components in transformers and bushings, on site, include:1) power factor/tan δ,2) variable frequency power factor/tan δ (1 - 500 Hz)3) dielectric frequency response (DFR) [a dielectric response method], and4) moisture in oil measurements (for transformers).
-
Product
Instrument Transformer Test Systems
-
Our systems for testing voltage (VT) and current (CT) instrument transformers are conceived among other things for testing accuracy and insulation.
-
Product
High Voltage Transformer
-
RR manufactures HIGH VOLTAGE TRANSFORMERS for various Industrial Applications.
-
Product
Zero Phase Current Transformer
MZL-45
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
Split-core type for measuring zero phase current
-
Product
Transformer Resistance Testing
-
Weshine Electric Manufacturing Co., Ltd
Transformer insulation resistance deterioration is one of the most common causes of transformer failure: a failing transformer is a costly replacement in an electrical system with the potential for a long downtime. If you fail to maintain your transformer with regular insulation resistance testing (as can be carried out by the WESHINE Transformer Ohmmeter (VS-3110 series) of transformer test equipment) then it’s likely to fail before reaching its maximum operating life.
-
Product
Automatic Transformer Test System
TH2829LX
-
Changzhou Tonghui Electronic Co., Ltd.
Number of Test PIN: 20 ■ Frequency: 20Hz-200kHz, Resolution: 0.5mHz ■ Signal Level: 5mV-2Vrms(Option:2mV-10Vrms) ■ Test Speed: max. 13ms ■ 7-inch TFT LCD display with a resolution of 800×RGB×480
-
Product
Harmonic Mitigation Transformer
-
A specialized three-phase transformer designed to reduce harmonic distortion and voltage distortion caused by non-linear loads (e.g., computers, VFDs) in electrical distribution systems.
-
Product
Transformer Analyzer
505
-
The UTEC 505 Transformer Analyzer is designed for testing current transformers (CT) and potential transformers (PT) without interruption of the customer’s service. This instrument measures CT admittance, CT ratio, CT primary-to-secondary phase angle and the voltage, current and phase angle of the service. With the ‘Burden CT/PT Option’, it determines the CT secondary burden capability, the regulation of the PT and its secondary burden capability and provides for CT core demagnetization.
-
Product
Transformer Test Equipment
-
A range of equipment dedicated to the testing of transformers of all types and sizes.
-
Product
Multiple Gas Transformer DGA
MINITRANS
-
Based on the same core technology as the highly successful TRANSFIX the MINITRANS is a lower cost alternative, monitoring three key gases: Hydrogen, Acetylene and Carbon Monoxide (in ppm) plus moisture in oil (%RH & ppm). The measurement of these gases allows the user to detect a wide range of developing faults including arcing.
-
Product
Automatic Transformer Tester
SS3250 / SS3252 / SS3302
-
Automatic transformer test instrument is a precision test system, designed for transformer production line or incoming/outgoing inspection in quality control process, with high stability and high reliability. With the enhanced capability in turn ratio measurement, they can solve the measuring problems of low coupling coefficient, transformer's turn ratio and turn number with more precise measurement.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
-
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
Product
Three-Phase Transformer Demagnetizer
DEM60C
-
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.