Filters
Electronic circuits which refine signal by blocking certain frequencies, while allowing other frequencies to pass.
See Also: Filter / Amplifiers, EMI Filters, Low Pass Filters, Programmable Filters, Attenuators
-
Product
GigE Vision Camera featuring the Sony IMX304 CMOS Sensor
Manta G-1236
-
Manta G-1236B/G-1236C is a machine vision camera that incorporates the high quality Type 1.1 (17.6 mm diagonal) Sony IMX304 CMOS sensor with Pregius global shutter technology. At full resolution, this camera runs 9.7 frames per second. With a smaller region of interest, higher frame rates are possible. The Manta is one of Allied Vision's versatile GigE Vision cameras with a wide range of features. Particular highlights are the three look-up tables, sophisticated color correction capabilities, a robust metal housing, and many modular options. By default monochrome models ship with protection glass B 270 (ASG) and color models ship with an IRC Hoya C-5000 IR cut filter.
-
Product
Video Op Amps
-
Analog Devices video amplifiers, buffers, and filters provide an ideal solution for your video amplification needs. Our easy to use amplifiers require few external components, with on-chip options available to help you minimize design time.
-
Product
PXIe-5160 PXI Oscilloscope, 500 MHz, 10 bits, 2.5 GS/s, 2 Channels, 2 GB
782621-02
Oscilloscope
PXIe, 500 MHz, 2.5 GS/s, 10-Bit PXI Oscilloscope—The PXIe-5160 high-speed oscilloscope device has two or four channels that sample at up to 2.5 GS/s with flexible settings for coupling, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with fast signals that require up to 500 MHz of analog bandwidth and flexible measurement configurations.
-
Product
Digital Module For Remote I/O
ITA
Digital Modules for Remote I/O provide 24 V digital inputs or outputs and offer 1‐, 2‐, 3‐, and 4‐wire spring terminal connection options. You can use inputs as counters or standard digital inputs, and you can adjust filter time to improve measurement quality. Inputs can include a built‐in power supply for sensors. Output modules feature circuit and overload protection and can drive up to 500 mA per channel, up to 8 A per module.A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the Digital Module for Remote I/O from a NI real‐time controller. You can use remote I/O hardware to add low‐cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high‐speed or specialty measurements.
-
Product
Metrology
-
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Network analyzers are used to measure so-called scatter parameters (S-parameters). These describe the behaviour of electrical components with the help of wave magnitudes. Whether simple cables, filters, amplifiers or complex subsystems, the following applies to all these components: Different loads can have unseen effects on the measured values over time.
-
Product
USB-5133, 50 MHz Bandwidth, 100 MS/s, 2-Channel, 8-Bit USB Oscilloscope Device
779970-02
Oscilloscope
50 MHz Bandwidth, 100 MS/s, 2-Channel, 8-Bit USB Oscilloscope Device - The USB‑5133 low-cost oscilloscope device has two channels that sample up to 100 MS/s with flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes and an instrument driver that includes data streaming and analysis functions. This device is ideal for portable and benchtop applications with fast signals that require flexible measurement configurations and up to 50 MHz of analog bandwidth.
-
Product
IntellaView
EdgeSwitch
-
The IntellaView EdgeSwitch is a high-density 1RU system with 32 ports of 40G / 100G Ethernet capability, while the breakout mode can support up to 128 ports of 10G / 25G. The EdgeSwitch enables efficient traffic aggregation, filtering, load balancing, tunnel management, and port tagging standalone or as part of a larger visibility solution.
-
Product
LISN Line Impedance Stabilisation Networks / AMN Artificial Mains Network
-
A LISN Line Impedance Stabilization Networks / AMN Artificial Mains Network: *supplies the neccessary mains voltage (AC or DC) and current for the Equipment under Test (EuT).*couples interference voltage generated by the EuT and supplies it to the receiver.*provides well defined RF-impedance to the Equipment under Test (EuT)*keeps away unwanted disturbance coming from mains (filter)*protects the mains from unwanted disturbance voltage generated by the EuT
-
Product
Ultra-Low Noise Filter, 42 V / 105 MA, 50 Ω
N1298B
Noise Filter
The N1298 Series is a collection of low noise filters for the Keysight B2960 Series 6.5-digit low noise source.
-
Product
T8730 AIR FLOW TESTER UNIVERSAL
-
T8730 was designed for the precise task of measuring flows on parts such as filters (medicinal, diesel or petrol), tubes, nozzles, openings, valves, etc…Other than the classic flow measurement, the tool also has other ways of making it as versatile as possible in its category: ascent and descent ramps, opening tests and burst testing.Another separate function is the "continuous measurement", i.e. a test with infinite times allowing adjustment of the taps and part repairs in real time.The tool also avails of an intelligent pressure adjustment, which uses the automatic pressure regulator to continuously adjust the test pressure based on the variation in load loss, to ensure the reading is as stable and repetitive as possible.
-
Product
PXIe-5105, 60 MHz, 8-Channel 128 MB, 12-Bit PXI Oscilloscope
783590-02
Oscilloscope
PXIe, 60 MHz, 8-Channel, 12-Bit PXI Oscilloscope—The PXIe‑5105 high-density PXI oscilloscope has eight simultaneously-sampled channels with flexible settings for coupling, impedance, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with many channels that require up to 60 MS/s or 60 MHz of analog bandwidth. The PXIe‑5105 also features advanced PXI synchronization and data streaming capabilities.
-
Product
Chemiluminescence NO/NO2/NOX Analyzer
Model T200
-
Teledyne Advanced Pollution Instrumentation
The Model T200 NO/NO2/NOx analyzer uses the proven chemiluminescence detection principle, coupled with state-of-the-art electronics to allow accurate and dependable low level measurements for use as an ambient analyzer or dilution CEMS monitor.A unique AutoZero feature provides superb stability by continuously correcting for zero drift, while advanced Adaptive Filtering allows the analyzer to optimize performance under changing conditions. The Model T200 includes a permeation inlet dryer for ozone generation to provide excellent reliability with no periodic replacement required. A catalytic exhaust ozone scrubber is standard for maximum safety and pump life.
-
Product
1U Louvered Plastic Grille with Filter
GP-119
-
1U high louvered plastic grille with filter is made of polycarbonate resin.
-
Product
High Speed Data Acquisition Board
MS 1800
-
*Bus Interface:- 64 Bit PCI Bus with PMC Interface*Virtex-4 FPGA based design*32 channel digital I/O signal*RS232 & RS485 Interface*32MB Flash*2MB Static RAM for data storage*Analog Inputs:- 2 Channel*Input Resolution:- 14 Bits*Sampling rate up to 80MSPS*Filter:- Low Pass Filter for all channels*Two Analog Outputs*14 bit Resolution*Driver interface for Windows2000/XP/VISTA and LINUX OS*Self Test future
-
Product
Multicode Reader
IDC Series
-
The IDC Multicode Reader reliably recognizes every standard industrial 1D/2D codes, texts (OCR) and direct part marking codes (DPM) on most varied materials. Advanced functions for data validation, filtering and formatting ensure smooth integration into existing processes.
-
Product
Board Cameras
-
e-CAM & See3CAM Series of Camera Boards. e-CAM camera board is e-con's reference design featuring a board camera interfaced to a processor on its high speed CMOS interface. Board cameras are available for Jetson Developer kits and NXP i.MX6 boards. For processors, that don't have the Camera ISP pipeline, e-con Systems provides the complete software stack for raw image sensors. The software stack has a wide variety of features ranging from color correction, gamma correction, dead pixel correction, color space conversion, sharpen filter etc.
-
Product
Light Meters
LXP-2
-
The digital light meter is a precision instrument used to measure illuminance (Lux, footcandle) in the field. It is meet CIE photopic spectral response. It is fully cosine corrected for the angular incidence of light. The illuminance meter is compact, tough and easy to handle owing to its construction. The light sensitive component used in the meter is a very stable, long-life silicon photo diode and spectral response filter.
-
Product
Automation
Signal Filtration
-
Signal Filtration is used for filtering signals coming to the input channels of spectrum analyzers, strain-gauge stations, and seismic stations, for further processing by ZETLAB programs. Signal Filtration can also be used for processing virtual channels created by such programs as Vibration Meter, Strain-Gauge Sensor, etc. Signal Filtration operates with signals both in real time and with reproduced of recorded signals.
-
Product
IEPE Signal Conditioning Amplifiers
-
Although IEPE (Integrated Electronics Piezoelectric) sensors is not a new technology there are a wide variety of applications where the measurement instrumentation is not configured with IEPE signal conditioning built in. In these situations it is necessary for the IEPE supply to be provided by an external source. Usually this type of instrument will also provide th user with the option to add gain to the signal being conditioned. The Kemo range of IEPE signal conditioning instruments can be used as stand alone conditioners/amplifiers are many of them can also be integrated with filters.
-
Product
Handheld Digital Multimeter, 4.5 digit, up to 800 hours battery life
U1282A
Digital Multimeter
60,000 counts resolution on dual display0.025% basic DC voltage accuracy Longer battery life up to 800 hours Certified to IP 67 for dust and water protection Tested to withstand a 3-meter (10-ft) drop Programmable via USB (Download Programming Guide here)CAT III 1000 V/ CAT IV 600 V overvoltage protection Vsense for non-contact voltage detection Square wave output for generating pulse width modulation (PWM) signal Frequency counter Low pass filter
-
Product
PXIe-5185, 3 GHz, 12.5 GS/s, 8-Bit PXI Oscilloscope
782057-01
Oscilloscope
PXIe, 3 GHz, 12.5 GS/s, 8-Bit PXI Oscilloscope—The PXIe‑5185 high-speed PXI oscilloscope has two channels with flexible settings for coupling, voltage range, and filtering. PXI oscilloscopes also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with fast signals that require up to 3 GHz of analog bandwidth and flexible measurement configurations. The PXIe‑5185 also features PXI synchronization and data streaming capabilities.
-
Product
7U centrifugal 330 cfm blower for pressurizing consoles
CB-500A
-
7U centrifugal 500 cfm blower for pressurizing consoles, computers and electronic systems with cool, filtered air. Includes easy-to-remove, washable dust filter, 3-conductor AC cord and removable, brushed aluminum grille. Installs on 19” panel mounting rails.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF600
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensationof power factor in low voltage instalations.
-
Product
PXIe-4303 , 24-Bit, 32-Channel, 51.2 kS/s, ±10 V PXI Analog Input Module
783866-01
Analog Input Module
24-Bit, 32-Channel, 51.2 kS/s, ±10 V PXI Analog Input Module—The PXIe‑4303 is a filtered input module for voltage, thermocouple, and current measurements. The module offers you the ability to select a digital filter per channel to provide extra filtering performance. You also can operate up to four different sample rates and triggering configurations concurrently to ensure you measure every sensor as needed. The module has an A/D converter per channel to enable a simultaneous sample rate at the maximum sample rate across the input range. The included NI‑DAQmx driver simplifies hardware configuration and measurement.
-
Product
Handheld Particle Counters
Models 3888 And 3889
-
Kanomax’s innovative Handheld Particle Counters (Models 3888 & 3889) set the standard of instrumentation in cleanroom / operating room monitoring and verification, filter testing, IAQ investigation, data center cleaning and many more highly specialized and highly sensitive applications. These beautifully engineered devices boast some of the most highly advanced technology in the industry. A combination of accuracy and practicality, these devices count airborne particles with high quality performance.
-
Product
PXIe-4481, 24-Bit, 6-Channel, 1.25 MS/s/ch PXI Analog Input Module
784278-01
Analog Input Module
24-Bit, 6-Channel, 1.25 MS/s/ch PXI Analog Input Module—The PXIe‑4481 is an analog input module for higher bandwidth voltage measurements. The module offers analog and digital filtering for accurate frequency domain measurements. You also can select from four gain settings to configure your input range. For measuring sudden changes, such as high speed blast and pressure events, the PXIe-4481 can sample up to 20 MS/s per channel in time domain mode. The included NI-DAQmx driver simplifies hardware configuration and measurement.
-
Product
1pps-Locking-Modules
-
This is a module to control an OCXO or Rubidium oscillator with 1PPS from a GPS receiver. The Quartzlock A6-1PPS uses a 3 state Kalman filter algorithm to measure & correct the frequency offset of the oscillator with respect to the 1PPS input. Time-tagged input 1PPS to 200ps resolution & <1ns jitter. Analog interpolator is self calibrating. Interface to GPS decodes messages & extracts relevant info. i.e. time correction data for 1PPS output, this has AVAR of the Rb or OCXO i.e. 5 x 10-12/s & <100ps RMS jitter. The output is steered to time coincidence with GPS time/UTC to 1ns resolution. Holdover initiated by 1PPS fail or data from GPS RX that 1PPS is inaccurate. During holdover, measured frequency offset & drift steer the oscillator & 1PPS is still available.
-
Product
Modular RF Systems
-
Becker Nachrichtentechnik GmbH
Flexible modular system for customer specific system solutions without the effort of development and construction. The range of module types covers from active multicouplers, programmable attenuators, delay lines, RF switches, switching matrices, BIAS-Ts, RF filters up to bi-directional splitters and combiners.
-
Product
Cubes/Holders
-
IDEX Health & Science stocks filter cubes used in fluorescence microscope platforms from the major microscope manufacturers, including Leica Microsystems, Nikon Instruments, Olympus Corp., and Zeiss Microscopy. Our super-resolution filter cubes set the new standard for laser-based microscopes and are optimized for mounting half-wave flatness, 1 mm thick super-resolution dichroic beam-splitters. Whether you order a custom or catalog filter set, complimentary filter mounting into the filter cube of your choice is performed by the certified staff.
-
Product
Digital Receiver XMC
XF07-518
-
Curtiss-Wright Defense Solutions
The XF07-518 is a rugged quad channel 500MSPS 14-bit digital receiver XMC. The ADC devices are controlled by a user programmable Xilinx FPGA which allows high performance processing such as Digital Down Conversion (DDC), filtering and custom algorithms.