Voltage Calibrators
An accurate voltage units of measure to facilitate comparison to and adjustment of instruments.
See Also: Voltage Sensors
-
Product
Digital to Analog Converter
-
20-bit digital-to-analog (D/A) converter offering 20-bit monotonic performance over the specified temperature range. It utilizes delta-sigma technology to achieve inherently linear performance in a small package at very low power. The resolution of the device can be programmed to 20 bits for Full-Scale, settling to 0.003% within 15ms typical, or 16 bits for Full-Scale, settling to 0.012% within 2ms max. The output range is two times the external reference voltage. On-chip calibration circuitry dramatically reduces low offset and gain errors.
-
Product
Primary VoltageE Standard: Cryocooler (Closed- Cycle Refridgerator) System
-
The Hypres Primary Voltage Standard System with cryocooler (closed-cycle refrigerator) is a complete, computer controlled system implementing a variety of voltage calibration functions. This system configuration is a cryogen-free complete Primary Voltage Standard System with parameters that are identical to the liquid helium version.
-
Product
Portable Multifunction Calibrator
M143
-
Clarke-Hess Communications Research
The M143 Multifunction calibrator is a cost saving solution for calibration of electric meters with up to 1000 V and 20 A. It offersa basic accuracy of 0.01% in DC voltage for calibration of 3 and 4 digit multimeters. The resistance function is covered byeight fix resistors in range from 10 to 100 M. The calibrator offers TC temperature sensor simulation. It can be deliveredoptionally as well with RTD temperature sensor simulator. Thanks to its small dimensions and low weight the unit can be usedeasily for field calibration work.
-
Product
Partial Discharge Detection Calibration Device
-
Hangzhou Xihu Electronic Institute
Calibration Device of Transient Earth Voltage PD detector, calibration device of ultrasonic PD detector, calibration device of high frequency PD detector, calibration device of ultra high frequency PD detector.
-
Product
DC Josephson Voltage Standard
-
The system enables a number of calibration and measurement functions for dc voltages:*Calibration of secondary standards*Calibration of linearities and accuracies of dc voltmeters in the measuring range from 0 to ± 10 V.*Extremely exact output of any reference voltages*Direct comparison of two voltage standard measuring systemsNo other measuring system in the world offers such a variety with the highest precision.
-
Product
Micropotentiometers
1251
-
The BLI Series of Micropotentiometers consist of a Model 1251 terminating resistor and a Model 1351 Thermoelement housing. These micropots are true RMS current to voltage converters for calibrating AC instruments. The NIST calibration range is from dc to 500 MHz (available to 1.2 GHz)
-
Product
CALIBRATOR Multi Function Calibrator
MC140
-
The Multifunction Calibrator MC140 functions as a Voltage Calibrator, Current Calibrator, Power Calibrator, Resistance Calibrator, Capacitance Calibrator and a Thermocouple Calibrator.? Having very low uncertainties, it is ideal as a standard of these electric quantities in calibration laboratories.
-
Product
High Voltage Pulse Attenuators
-
Barth High Voltage Pulse Attenuators are matched impedance coaxial attenuators for use primarily in pulsed 50 ohm systems, or where occasional transients would damage ordinary units. The attenuator design closely matches the impedance around each resistor, to that resistor. These attenuators feature an input impedance very close to 50 ohms, with characteristics as good or better than most microwave attenuators. These units are ideal for use in nuclear and high energy experiments. Extensive testing during manufacturing insures very high reliability for single-shot experiments. A voltage coefficient of the resistive film of less than .0001 %/V allows low voltage calibration of most systems.
-
Product
Voltage Calibrators
-
Practical Instrument Electronics, Inc.
PIE has a voltage calibrator to fit your needs from the PIE 235 voltage and pH simulator to the advanced troubleshooting capabilities of the PIE 532 milliamp and voltage calibrator. The PIE 532 includes our patented Loop Diagnostic Technology! All the voltage/milliamp calibrators have fuse-less protection, rugged design and long battery life. With the PIE 535, source 4 to 20 milliamps or 10 to 50 milliamps into loop instruments and drive final control elements such as valves and actuators with up to 42 volts.
-
Product
High Temperature, Low Strain Capacitive Extensometers (1200 C or 1600 C)
Model 3648
-
Jinan Testing Equipment IE Corporation
These extensometers use a high temperature capacitive sensor in combination with an innovative design to achieve high accuracy strain measurements in low measuring ranges not possible with other high temperature extensometers. They mount on a slide bracket (included) that can attach to the load frame of your test system; optional load frame mounting brackets are available. The overall design reduces any influence from common lab environment vibrations.The standard temperature version (to 1200℃) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace. These units are made to order in many different gauge lengths and measuring ranges.The extensometer comes with a signal conditioner. The output is an analog DC voltage, factory calibrated with the extensometer to 0 to ±10 VDC typically. They are readily interfaced with most existing test controllers, and may be directly connected to data acquisition systems and chart recorders. Bringing the signal into a spare DC input channel (or external input) on the test controller allows the extensometer to be used for strain controlled tests like low cycle fatigue.
-
Product
Automated Potentiometer Systems
-
Measurements International Ltd.
Intrinsically Accurate Self-Calibrating Ratio Divider, Best Accuracy < 0.05 ppm, Built-in 20-Channel Scanner, Arbitrary Voltages from 1 mV to 1200 V, Bipolar Voltage Measurements, Calibration of Fluke 5700A/5720A, Calibration of 3458A and 8508A, Calibration of Voltage Ratio Dividers (F752A, MI 1340A, G7520), Linearity Calibration of Digital Volt Meters (DVM), Traceability to 10 V Zener Reference.
-
Product
15-meter (49 feet) Sensor Cable
E1739C
-
The E1739C 15-meter (49 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System. Other cable lengths available: E1739A 5-meter (16 feet), E1739B 10-meter (33 feet) and E1739D 25-meter (82 feet).
-
Product
Calibration Short For Digital Multimeters
34172B
-
The Keysight 34172B digital multimeter calibration short is a set of two shorts which provide a convenient and reliable method to apply a short to the input connectors of the multimeter. Terminals are made of low-thermal copper alloys to minimize thermally-induced voltages caused by dissimilar metals.
-
Product
NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle
865682-01
-
NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle - The USB Temperature Measurement Bundle with NI-9213, cDAQ-9171, and cRIO-9940 includes the NI-9213 C Series Temperature Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9213 provides noise immunity, a high common-mode voltage range, NIST-traceable calibration, differential analog inputs, and four channels. Additionally, the NI-9213 features anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements.
-
Product
AC Voltage Monitors
-
NAI's AC- and DC-powered AC voltage monitors are used to monitor and measure voltage characteristics of single- and three-phase power lines. Field-adjustable AC voltage monitors are also available. These monitors are specifically designed for rugged defense and industrial applications.
-
Product
Sensor Cable, 5 M
E1739A
-
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 4.3-10, 2 Port
85094D
-
The Keysight 85094D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, 7 Mm
85031B
-
The Keysight 85031B calibration kit contains a set of precision 7 mm fixed terminations and a one-piece open/short circuit used to calibrate Keysight network analyzers for measurement of devices with precision 7 mm connectors. This kit is specified from dc to 6 GHz.
-
Product
Electronic Calibration Module (ECal), 18 GHz, 7 Mm, 2-Port
N4696D
-
The Keysight N4696D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4696D is a precision 2-port ECal module that supports 7-mm connectors up to 18 GHz. The plastic storage case for the N4696D is included for securing your ECal module and accessories.
-
Product
Reference Voltage Measurement Cell
C-80
-
Cells C-80 and C-100 are used as reference devices for measuring voltage during calibration and adjustment of OLT-series testers.
-
Product
NI-9202, ±10 V, 10 kS/s, 24-Bit, 16-Channel C Series Voltage Input Module
784399-01
-
±10 V, 10 kS/s, 24-Bit, 16-Channel C Series Voltage Input Module - The NI-9202 has excellent flexibility to meet the needs of your applications. The module has 16 simultaneous sampling, differential input channels to create large, distributed systems in a rugged form factor. It also has configurable filters to eliminate noise in your system while maintaining low-latency to be used in control systems.
-
Product
4-In-1 OSLT Mechanical Calibration Kit, DC To 26.5 GHz, Type-3.5 Mm (m) 50 Ohm
85520A
-
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit.
-
Product
FD-11601, 8-Channel, ±10 V Powered-Sensor Voltage Input Device for FieldDAQ
786374-01
-
The FD-11601 measures up to eight channels with a voltage input range of ±10 V. Each input channel supports TEDS and provides 24 V DC to power external-powered sensors without additional power supplies. The FD-11601 features 24-bit resolution, simultaneous sample rates up to 100 kS/s/ch, and channel-to-channel isolation. It is IP65/IP67 rated to be dust-tight and water-submersible, operates in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11601 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11601 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11601 is ideal for test cell and outdoor environments.
-
Product
sbRIO-9215, Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Modul
780878-01
-
Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9215 performs differential analog input. The sbRIO‑9215 contains NIST‑traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module
779785-02
-
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
Product
Electronic Calibration Module (ECal), DC-4 GHz, 2-Port
N7550A
-
The N7550A is part of Keysight’s family of value-line electronic calibration (ECal) modules that makes calibration of vector network analyzers fast, easy and accurate. Cut your calibration down to half the time it normally takes using a traditional mechanical cal kit. Simply connect it to your instrument and the firmware does the rest. For greater precision and higher accuracy measurements consider the N44xx and N469x family of ECal products.
-
Product
AC-Powered, AC Voltage Monitor, Adjustable
VMA
-
NAI’s VMA is a field-adjustable, AC-Powered, AC Voltage Monitor used to monitor voltage characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power-line characteristics are within pre-determined limits.High and low voltage limits, and "pick-up" and "drop-out" time delay are field-adjustable. The VMA voltage monitor is ideally suited for rugged defense and industrial applications.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7–16 (male)
85038M
-
Modern wireless communication systems require high-performance components offering low VSWR and low intermodulation distortion at high transmit power levels. To meet these needs, 7-16 connectors are becoming increasingly common in base station transmitters, amplifiers, duplexers, and other products. These connectors conform to IEC 169-4, DIN 47223, European standard EN 122190, and British standard BSEN 122190.
-
Product
NI-9222 , ±10 V, 500 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
781397-01
-
±10 V, 500 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9222 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The NI‑9222 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the NI‑9222: a 10‑position screw terminal or a 25‑pin D‑SUB connector.
-
Product
NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module
779785-01
-
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.