Voltage Calibrators
An accurate voltage units of measure to facilitate comparison to and adjustment of instruments.
See Also: Voltage Sensors
-
Product
Voltage Calibrators
-
Practical Instrument Electronics, Inc.
PIE has a voltage calibrator to fit your needs from the PIE 235 voltage and pH simulator to the advanced troubleshooting capabilities of the PIE 532 milliamp and voltage calibrator. The PIE 532 includes our patented Loop Diagnostic Technology! All the voltage/milliamp calibrators have fuse-less protection, rugged design and long battery life. With the PIE 535, source 4 to 20 milliamps or 10 to 50 milliamps into loop instruments and drive final control elements such as valves and actuators with up to 42 volts.
-
Product
NI-9215, cDAQ-9171, and NI-9981 USB Voltage Measurement Bundle
865684-01
-
NI-9215, cDAQ-9171, and NI-9981 USB Voltage Measurement Bundle - The USB Voltage Measurement Bundle with NI-9215, cDAQ-9171, and NI-9981 includes the NI-9215 C Series Voltage Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the NI-9981 Connector for strain relief and operator protection from high-voltage signals. The included NI-9215 provides noise immunity, a high common-mode voltage range, NIST-traceable calibration, differential analog inputs, and four channels.
-
Product
CALIBRATOR Multi Function Calibrator
MC140
-
The Multifunction Calibrator MC140 functions as a Voltage Calibrator, Current Calibrator, Power Calibrator, Resistance Calibrator, Capacitance Calibrator and a Thermocouple Calibrator.? Having very low uncertainties, it is ideal as a standard of these electric quantities in calibration laboratories.
-
Product
Partial Discharge Detection Calibration Device
-
Hangzhou Xihu Electronic Institute
Calibration Device of Transient Earth Voltage PD detector, calibration device of ultrasonic PD detector, calibration device of high frequency PD detector, calibration device of ultra high frequency PD detector.
-
Product
DC Josephson Voltage Standard
-
The system enables a number of calibration and measurement functions for dc voltages:*Calibration of secondary standards*Calibration of linearities and accuracies of dc voltmeters in the measuring range from 0 to ± 10 V.*Extremely exact output of any reference voltages*Direct comparison of two voltage standard measuring systemsNo other measuring system in the world offers such a variety with the highest precision.
-
Product
Micropotentiometers
1251
-
The BLI Series of Micropotentiometers consist of a Model 1251 terminating resistor and a Model 1351 Thermoelement housing. These micropots are true RMS current to voltage converters for calibrating AC instruments. The NIST calibration range is from dc to 500 MHz (available to 1.2 GHz)
-
Product
Primary VoltageE Standard: Cryocooler (Closed- Cycle Refridgerator) System
-
The Hypres Primary Voltage Standard System with cryocooler (closed-cycle refrigerator) is a complete, computer controlled system implementing a variety of voltage calibration functions. This system configuration is a cryogen-free complete Primary Voltage Standard System with parameters that are identical to the liquid helium version.
-
Product
Digital to Analog Converter
-
20-bit digital-to-analog (D/A) converter offering 20-bit monotonic performance over the specified temperature range. It utilizes delta-sigma technology to achieve inherently linear performance in a small package at very low power. The resolution of the device can be programmed to 20 bits for Full-Scale, settling to 0.003% within 15ms typical, or 16 bits for Full-Scale, settling to 0.012% within 2ms max. The output range is two times the external reference voltage. On-chip calibration circuitry dramatically reduces low offset and gain errors.
-
Product
NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle
865682-01
-
NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle - The USB Temperature Measurement Bundle with NI-9213, cDAQ-9171, and cRIO-9940 includes the NI-9213 C Series Temperature Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9213 provides noise immunity, a high common-mode voltage range, NIST-traceable calibration, differential analog inputs, and four channels. Additionally, the NI-9213 features anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements.
-
Product
Automated Potentiometer Systems
-
Measurements International Ltd.
Intrinsically Accurate Self-Calibrating Ratio Divider, Best Accuracy < 0.05 ppm, Built-in 20-Channel Scanner, Arbitrary Voltages from 1 mV to 1200 V, Bipolar Voltage Measurements, Calibration of Fluke 5700A/5720A, Calibration of 3458A and 8508A, Calibration of Voltage Ratio Dividers (F752A, MI 1340A, G7520), Linearity Calibration of Digital Volt Meters (DVM), Traceability to 10 V Zener Reference.
-
Product
High Voltage Pulse Attenuators
-
Barth High Voltage Pulse Attenuators are matched impedance coaxial attenuators for use primarily in pulsed 50 ohm systems, or where occasional transients would damage ordinary units. The attenuator design closely matches the impedance around each resistor, to that resistor. These attenuators feature an input impedance very close to 50 ohms, with characteristics as good or better than most microwave attenuators. These units are ideal for use in nuclear and high energy experiments. Extensive testing during manufacturing insures very high reliability for single-shot experiments. A voltage coefficient of the resistive film of less than .0001 %/V allows low voltage calibration of most systems.
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
Calibration Cable
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, 7 Mm
85031B
Mechanical Calibration Kit
The Keysight 85031B calibration kit contains a set of precision 7 mm fixed terminations and a one-piece open/short circuit used to calibrate Keysight network analyzers for measurement of devices with precision 7 mm connectors. This kit is specified from dc to 6 GHz.
-
Product
Multiport Electronic Calibration Module (ECal), DC To 9 GHz, 6-ports
N7562A
Electronic Calibration Module
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 9 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
RF Electronic Calibration Module (ECal), 300 KHz To 18 GHz, 4-ports
N4432D
Electronic Calibration Module
The Keysight N4432D is a precision 4-port ECal module that supports selection of Type-N and 3.5 mm connectors mixed up to 18 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
CalPod Drive Cable, 40 GHz, 2 Meter
85553A
Calibration Cable
This cable provides the bias voltages and control signals for operation of the 40 GHz CalPod modules. This cable is supplied with the 85540/41/42A CalPod modules.
-
Product
NI-9202, ±10 V, 10 kS/s, 24-Bit, 16-Channel C Series Voltage Input Module
784400-02
Voltage Input Module
±10 V, 10 kS/s, 24-Bit, 16-Channel C Series Voltage Input Module - The NI-9202 has excellent flexibility to meet the needs of your applications. The module has 16 simultaneous sampling, differential input channels to create large, distributed systems in a rugged form factor. It … also has configurable filters to eliminate noise in your system while maintaining low-latency to be used in control systems.
-
Product
NI-9221, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
779373-02
Voltage Input Module
±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the NI‑9221: a 36‑position spring‑terminal connector and a 37-position D‑SUB connector.
-
Product
NI-9242, 250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module
783107-01
Voltage Input Module
250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9242 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, standard potential transformers, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9242 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
Electronic Calibration Module
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Mechanical Calibration Kit, 18 To 26.5 GHz, Waveguide, WR-42
K11644A
Mechanical Calibration Kit
The Keysight K11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the Thru-Reflect-Line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
Product
NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module
779785-02
Voltage Input Module
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
Product
NI-9263, 100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module
779012-01
Voltage Output Module
100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module - The NI‑9263 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST‑traceable calibration. The NI‑9263 module includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
Product
AC Voltage Monitors
Voltage Monitor
NAI's AC- and DC-powered AC voltage monitors are used to monitor and measure voltage characteristics of single- and three-phase power lines. Field-adjustable AC voltage monitors are also available. These monitors are specifically designed for rugged defense and industrial applications.
-
Product
Multiport Electronic Calibration Module (ECal), DC To 20, 6-ports
N7564A
Electronic Calibration Module
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 20 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
NI-9239, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
779593-01
Voltage Input Module
±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the NI‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range.
-
Product
NI-9252, ±10 V, 50 kS/s/ch, 24-Bit, 8-Channel C Series Voltage Input Module
786783-01
Voltage Input Module
±10 V, 50 kS/s/ch, 24-Bit, 8-Channel C Series Voltage Input Module - The NI-9252 is an 8-channel analog input module for CompactDAQ and CompactRIO systems. Each channel provides a ±10 V measurement range and 24 bits of resolution at a 50 kS/s sample rate. The NI-9252 features a number of programmable hardware filters. By choosing the specific Butterworth and comb filters for your application, you can significantly reduce the noise in your system.
-
Product
sbRIO-9223, Non-Enclosed, ±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
785480-01
Voltage Input Module
Non-Enclosed, ±10 V, 1 MS/s, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO-9223 performs differential analog input. This module is well suited for applications such as ballistics, impact, and blast wave testing. The sbRIO-92233 can sample at the maximum sample rate per channel while the module next to it samples at a much slower rate, which is ideal for mixed-measurement test systems. There are two connector options for the sbRIO-9223: a 10‑position screw terminal or a 25‑pin D‑SUB connector.
-
Product
sbRIO-9205, Non-Enclosed, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module
784787-01
Voltage Input Module
Non-Enclosed, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The sbRIO‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the sbRIO‑9205 includes up to 60 V of overvoltage protection between input channels and common (COM). In addition, the sbRIO‑9205 also includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection. Non-enclosed modules are designed for OEM applications.
-
Product
Cal Kit, 4-in-1 OSLT, DC To 26.5 GHz, 3.5 Mm(f)
85521A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit