Filter Results By:
Products
Applications
Manufacturers
Magnetic Field
an force around magnets, electric current and atomic orbits.
See Also: Magnetic, Magnetic Test, Magnetic Head, Magnetic Susceptibility, Magnetic Flux, Magnetic Stripe, Magnetic Permeability, H-field, Magnetic Field Mapping, Magnetic Field Meters, Magnetic Field Probes, Magnetic Field Sensors, Magnetic Field Test, Helmholtz Coils
- TEAM SOLUTIONS, INC.
product
HandyScope HS6-DIFF With EMI & SafeGround: 1 GS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-1000XMEG-W5
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEG EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
product
Relay / Magnetic Field Testers
PeakTech Prüf- und Messtechnik GmbH
Ideally suited for checking magnetic fields and the correct function of coils, e.g. Relays and solenoid valves. The magnetic field detector works without contact, so that opening the housing is not necessary in most cases. When a magnetic field is detected, the probe tip lights up permanently blue, with clocked relays in the same cycle as they are controlled. The function of the magnetic field detector can be checked before each measurement with the enclosed test permanent magnet.
-
product
Vehicle Electromagnetic Field Exposure Test System
SEM-400
Beijing KeHuan Century EMC Technology Co,.LTD
Vehicles are our daily public transportation. Electromagnetic pollution in vehicles has attracted more and more public attention. The newly revised compulsory standard GB27630-201X "Passenger Car Air Quality Evaluation Standard" intends to require the electromagnetic field in the car as one of the indicators, according to GB/T37130-2018 "Measurement method of vehicle electromagnetic field relative to human exposure" The measurement method is to measure the intensity of the magnetic field in the car. In the frequency range of 10Hz-400kHz, the electromagnetic field measurement result should meet the public limit requirements of GB8702-2014 for electromagnetic exposure.
-
product
Electro Magnetic Meter
This meter is used to indicate radiated electromagnetic fields. Wherever there is a voltageor a current, electric (E) and magnetic (H) fields arise.
-
product
MARATON Moderate HE
MARATON is a family of MAgnetic field and RAdiation TOleraNt power supplies developed for CERN LHC. MARATON MHE represents a 12 channel low-voltage power supply for installation in a moderate hostile environment with integrated CANbus remote monitoring and control interface. Voltages, currents, temperatures and output power are controlled by the internal processor and illegal modes as well as failure will be detected.
-
product
Near Field Probes
Used for accompanying measurements of high-frequency, electric and magnetic RF fields on assemblies and devices.
-
product
Biomagnetic Devices
Electrical measurements of physiological potentials are well established in clinical diagnostics. The flow of an electrical current creates a corresponding magnetic field. Thus bioelectric activity will generate biomagnetic fields. These fields can be detected with Tristan SQUID magnetometers. For many of the classical electrical techniques such as ECG and EEG, there are corresponding magnetic techniques (magnetocardiography or MCG and magnetoencephalography or MEG). In some cases (magnetopneumography, hepatic iron store measurements, intestinal ischemia, peripheral nerve and muscle activity), there is no corresponding electrical technique and biomagnetic measurements offer unique measurement capabilities. Unlike CT or MRI imaging which yield structural information, biomagnetic measurements offer real-time functional imaging.
-
product
Near Field Probes 30 MHz up to 3 GHz
RF2 set
The RF2 near field probe set consists of 4 passive near field probes for measurements in the development phase of the magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF2 set allow the step by step localization of interference sources of the RF magnetic field on assemblies. From greater distances the electromagnetic interference can be detected by RF-R 400-1 and RF-R 50-1 probes. The RF-B 3-2 and RF-U 5-2 probes with their higher resolution can more precisely detect the interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
product
Hall Effect Measurement Equipment
HEM
The physical quantity of Hall Coefficient, Hall Mobility and Carrier Density etc. can be investigated by measuring at room temperature voltage occurred perpendicularly to the both magnetic field and constant-current when flowing constant-current perpendicularly to magnetic field from current source while applying magnetic field to sample set at the center of magnetic field of magnet.
-
product
Vector Magnetometer
FVM400
Macintyre Electronic Design Associa
The FVM400 uses fluxgate technology to measure the three vector components of the magnetic field. The fluxgate sensors are packaged in a 1" square by 4" long probe that is connected to the handheld electronics unit by a modular telephone cord. The sensor can be located up to 100 feet from the electronics unit.
-
product
Fluxmeter
480
The Model 480 is a laboratory grade fluxmeter, for use with a Helmholtz coil or custom search coils. This instrument measures the total flux of a magnet part, which can be related to the magnetic field strength. Applications include magnet testing, magnetizing, and automated field measurement. In order to provide accurate and repeatable measurements, automatic or manual drift compensation is available to the user. A peak mode allows even the fastest magnetic pulse, such as those from a magnetizer, to be accurately measured. The Model 480 is also useful for measuring AC fields that are too high in frequency for a gaussmeter to detect. Relay outputs and an external reset input allow for simple automation functions to be implemented, while the RS232C and IEEE-488 ports permit advanced control of the fluxmeter via a remote computer or automation equipment.
-
product
TMR Linear Sensors
MultiDimension Technology Co.,Ltd.
Linear sensor utilizes a unique push-pull half bridge composed of four unshielded TMR sensor elements. The unique bridge design provides a high sensitivity signal output that is linearly proportional to a magnetic field applied parallel to the surface of the sensor package, and it provides superior temperature compensation of the output.
-
product
Magnetic Field Tester
MS-440
This device recognises fast and simply magnetic fields generated by electric reels and permanent magnets.
-
product
Gaussmeter
450
The Model 450 is a high-resolution, laboratory gaussmeter, capable of measuring magnetic fields from 0.001 Gauss to 300k Gauss (measurement range is dependent on probe used). This unit is designed for demanding applications, such as material analysis and field mapping, where low-noise, high-resolution magnetic measurements are necessary. Measurements of AC and DC magnetic fields are shown in Gauss or Tesla on the two-line vacuum fluorescent display. The Model 450 features RS232C and IEEE-488 ports, allowing the instrument to be controlled via a remote computer or automation equipment. A hall-effect gaussmeter probe is included with the Model 450, and may be selected from an extensive line of probe
-
product
Scanning Probe Microscopy
SPECS Surface Nano Analysis GmbH
As Scanning Probe Microscopy (SPM) is a key tool for nanotechnology, SPECS offers dedicated solutions for highly demanding requirements.In UHV, strong emphasis lies on spectroscopic methods such as scanning tunneling spectroscopy and inelastic tunneling spectroscopy as well as single atom and molecule manipulation. With the invention of a Joule-Thomson cryostat by Prof. Wulf Wulfhekel, SPECS now offers the JT-STM , operating sample and sensors in thermal equilibrium below 1K with optional high magnetic field.
-
product
Helmholtz Coils
Helmholtz coils is a candidate test apparatus for low frequency magnetic field susceptibility testing on military equipment and subsystems. Use of this coils reduce electromagnetic compatibility (EMC) qualification tests time, and subject the equipment under test (EUT) to a relatively uniform field.
-
product
Electrical Current Sensors
Electrical current sensors detect the flow of current along an electrical wire by measuring (or sensing) the magnetic field that is generated by the flow of electrical current. The sensors output signals that are transmitted to dataloggers
-
product
Low-Noise Fluxgate Sensor
FL1-100
Fluxgate magnetic field sensor with sub-nanotesla resolution and exceptionally low noise. Suitable for detection of fine metal parts in food, measurement of magnetic signatures, paleomagnetic applications, precision navigation, surveillance, shielding technology, and more.
-
product
Magneto-electric Testing
An exciting new area of scientific exploration examines the potential usefulness where magnetic field effects occur simultaneously with ferroelectric effects in materials and structures. Where these two properties, ferromagnetism and ferroelectricity, are coupled in the same material, the material is called a multiferroic. Radiant offers Magnetoelectric response bundle/software package to measure the magnetic coupling of multiferroic or magnetopiezoelectric devices.
-
product
Monitoring Loops
The Loop Sensor was designed to monitor the generated magnetic fields in radiated susceptibility tests.
-
product
Portable Digital Tesla Meter
HT20
This instrument is convenient for operator to measure magneticinduction of DC magnetic field accurately. It is characterized by its wide range, clear display of LCD, and indefectible structure of sensor.A piece of 9V dry battery, which acts as its power supply, can servefor 4 hours continuously. Meanwhile, regulated power supply (enclosed) is available to 220VAC.
-
product
Multi-Sensor
Panda
The NeuLog Panda multi-sensor can be used for any science experiment which utilizes Room Temperature, Light, Barometric pressure, Altitude, Sound, Relative Humidity, Dew-Point, Magnetic Field and G-Acceleration readings.Panda is used for environmental data collection and other experiments in Natural Science, Biology, Physics and Chemistry. It is specially designed for primary school level.The multi-sensor comes pre-calibrated so you can start experimentation right out of the box
-
product
SparkFun Triple Axis Magnetometer Breakout
MLX90393 (Qwiic)
It's time to start utilizing the superior magnetometer, and what better way than to throw it onto an easy-to-use breakout board? The SparkFun MLX90393 Magnetometer Breakout is a triple-axis magnetic sensor board capable of sensing very small fields, while still behaving as one would expect during saturation in larger fields (like a nearby magnet). The MLX90393 breakout can be used as a compass sensor but also works well as a non-contact controller, a flow meter with a magnetic impeller, or a linear actuator position sensor. To make it even easier to to get your readings, all communication is enacted exclusively via I2C, utilizing our handy Qwiic system. However, we still have broken out 0.1"-spaced pins in case you prefer to use a breadboard.
-
product
AC Clamp Meters
Cambridge Instruments & Engineering Co.
A clamp meter is a clothespin-shaped instrument that can be clamped around a live wire in order to measure the current it's carrying. As a measurement principle, clamp meters detect the magnetic field emitted by current flowing in a wire in order to measure the current value.
-
product
Handheld Digital Thickness Gauges
HC-210
Shenzhen Chuangxin Instruments Co., Ltd.
HC series of coating thickness gauge is a portable thickness gauge with eddy current thickness method and electromagnetic thickness method. It can be used to quickly and accurately measure the thickness of coating or cladding material without damaging it. As an essential instrument for professional material protection, this coating thickness gauge is widely used in manufacturing industry, metal processing industry, chemical industry and commodities inspection etc., both in the laboratory and in the engineering field. It can measure the thickness of nonmagnetic layer on magnetic metal substrate condition (such as steel, iron, alloy and hard magnetic steel, etc.) and the thickness of conductive layer on nonmagnetic metal substrate condition (such as rubber, paint, plastic, anodic oxidation film, etc.).
-
product
Digital Arrester Clamp Tester
ALCL-40
MULTI MEASURING INSTRUMENTS Co., Ltd.
*ALCL-40 is designed to test the diagnostic of OXIDE SURGE ARRESTER.*The least influence from the external magnetic field and noise by triple shielding of CT.*Compliant with IEC6099-5.*Enabled the measurements for 100nA resolution and harmonics current.
-
product
Sensitivity Testing
Response Dynamics Vibration Engineering, Inc.
Sensitivity testing involves making predictions of system response to environmental disturbance. The significance and importance of the system sensitivity estimates is very often overlooked. This gets companies in trouble and is one of the top reasons why we are called upon to provide timely solutions. Most teams are focused on getting their product to work and get it out the door. An engineering team will often not know how to quantify what to expect in the customer environment and how to test for those expected disturbances. We design hundreds of sensitivity tests and can explain the important concepts to consider in designing the tests and making the right measurements that allow for sound estimates of system response. This is an important expertise we use in our vibration, acoustic and magnetic field consulting services.
-
product
IGNITION COIL TESTER - ORANGE
MD76500M
*Non-intrusive, quick check tool instantly verifies active or inactive coil operation*Detects the magnetic field created by a coil energizing*Tool can be used to test coil on plug, coil near plug and coil pack systems
-
product
Tesla Meter
GX-100/GX-200
It can measure tiny magnetic field from 0.01mT. Both AC and DC can be measured without select.
-
product
Field Sensor
TR_B
The terraTEM TR_B Field surface sensor has been fully integrated to work seamlessly with the terraTEM. Recording three components of the Earth’s magnetic field simultaneously, the TR_B Field sensor comes with solid state rotation elements to be used in conjunction with the terraTEM inbuilt rotation software. The sensor also has automatic nulling of the ambient B-field.
-
product
Vector Field and Multi-Axis Systems
Cryogenic vector magnet systems allow precise alignment of the magnetic field to an exact direction in a measurement sample. The system provides the capability of orienting the magnetic field to any vector direction. This is suitable for experiments where samples cannot be moved easily.