Filter Results By:
Products
Applications
Manufacturers
-
product
High-Temperature and High-PressurepH Electrodes
UltraDeg
Corr Instruments offers a full range of exceptionally high performance, high-temperature and/or high-pressure UltraDeg probes, including pH electrodes, reference electrodes, platinum conductivity probes, and ORP(redox) electrodes, for temperatures up to 650F (343C) and pressures up to 5100 psi (35 MPa). These probes are ideal tools for corrosion monitoring, thermodynamic or electrochemical studies in harsh environments such as steam generators, nuclear power reactors, geothermal systems, deep oil/gas wells, and super critical water systems. Many of these UltraDeg probes are built upon our innovative sealing compound, Queon, which is the only known material in the world for sealing electrical conductors in metal sealing glands or compression feedthroughs that are operable at temperatures between 400F (200C) and 650F (343C).
-
product
Multi-Function Recorder
Platinum 2.5K
For all types of power system events, the Platinum 2.5K Multi-Function Recorder provides all the information you need to capture the complete picture. This comprehensive fault recorder simultaneously performs transient, sequence of events and disturbance recordings, phasor measurements and power quality analysis. All of these functions are performed at the highest level so it will meet your needs of today and the future. In a deregulated environment, the Platinum 2.5K is the best tool to provide the necessary data to increase revenues and retain your customer.
-
product
Independent 24-bit Sigma-Delta Type (One for Each Channel)
TR1
The TR1 provides 8 channels which can be individually programmed as a Thermocouple (TC) or a Resistance Temperature Detector (RTD) measurement interface. When configured as a TC, the channel can interface with virtually all thermocouple-type NIST temperature ranges. When configured as an RTD, the channel can interface to two, three and four-wire platinum RTD sensor configurations.
-
product
Diode Temperature Monitor
SIM922
Stanford Research Systems, Inc.
The SIM922 Diode Temperature Monitor and the SIM923 Platinum RTD Monitor are designed to measure four sensors simultaneously. Based on the modular SIM platform, they provide high-performance and multiple-channel capability in a small footprint.
-
product
Temperature Transmitter
Knick Elektronische Messgeräte GmbH & Co. KG.
Transmitters for platinum temperature sensors and thermocouples in 6 mm housing with calibrated range selection. Functional safety up to SIL 2, SIL 3 redundant to parameterization via interface or intuitively, directly on the device. Universal use with 24 V DC or AC power supply.
-
product
Portable Multi-Function Recorder
Platinum 2.5K/Portable
The Platinum 2.5K Portable Multi-Function Recorder is packaged in a rugged case with quick connect interfaces for fast and simple field connection. Interface cables are provided with shrouded banana jacks that couple easily with a variety of measurement CT’s and voltage scaling devices offering complete flexibility for power utility and industrial use. The Platinum 2.5K Portable Multi-Function Recorder utilizes a 40GB solid state drive that eliminates the need for a mechanical hard drive and stores over 1,000 fault and disturbance records at once. It meets regulatory compliances including PRC-002-2.
-
product
RJ45 Port Saver
#21025C
Extend the life of your tester by using the RJ45 PortSaver as your sacrificial cable. Eliminates the wear and tear from constantly plugging in and out of the tester port and minimizes the risk of damaging the RJ45 jack if the connector contacts are not crimped completely. Compatible with all Platinum Tool testers with built-in […]
-
product
Digital Melting Point Apparatus
DRK8011
Shandong Drick Instruments Co., Ltd.
DRK8011 Digital melting point apparatus is fully in line with ‘humanize’ of the design concept, using photoelectric automatic detection, dot matrix image LCD technology, digital keyboard input, each measuring one sample, measure three times the average of the melting point of the automatic strike, and has a melting, melting end automatically, melting curve automatic recording function. Temperature system uses high inearity make platinum resistance sensing element, the use of PID regulationtechnology to improve theaccuracy and reliability of the melting point, and with integrated electronic circuits to achieve rapid "starting temperature" setting and eight stalls to choose from linear "heating rate" Automatic Control. Instrument to establish communication with the PC via USB, save or print the graph, the instrument can be directly connected with the RS232 mini-printers, print graphs. The instrument uses Pharmacopoeia as a sample capillary tube.
-
product
Force Tensiometers
Sigma 702
The Sigma 702 is a standalone force tensiometer that provides accurate surface and interfacial tension measurements (Platinum Du Noüy ring, Platinum Wilhelmy Plate), manual determination of Critical Micelle Concentration (CMC) and density measurements. The open design and convenient control keyboard operations make these instruments easy to use without the need for an external computer.
-
product
Ultrasonic Flow Meters
Dalian Taijia Technology Co.,Ltd
RS485 .4-20mA and OCT output● 4-20mA and PT100 platinum resistance input● 2×20 English letters LCD display● 4 key tactile-feedback membrane keypad● IP57● Operate with clamp on, insertion and flow-cell transducer● Pipe diameters from 15mm to 6000mm
-
product
Electrochemical (Molecular Electronic Transfer) Motion Sensor transducers
The Molecular Electronic Transfer Technology
The basic design of the MET transducer, shown in Figure 1. The transducer is contained in a channel, 1, of a sensor filled with a specially prepared electrolytic solution. It consists of four fine platinum mesh electrodes, two anodes, 2, and two cathodes, 3, separated by thin, microporous ceramic or polymer spacers 4. Such an assembly is held together by a housing 5. To measure the motion of the fluid, it must be converted into an electrical signal. One way of achieving this is by using the convective diffusion of the ions in the electrolyte. At the heart of a MET device are inert electrodes at which a reversible redox reaction occurs, which does not involve either plating of a metal or evolution of a gas.
-
product
Portable XRF Analyzer
GoldXpert
XRF is a widely used, proven, and accepted method of chemistry analysis and determination of purity and fineness of precious metals. XRF analysis is a multielemental testing alternative that is quicker and less expensive than fire assay and chemical tests. XRF provides on-the-spot analysis of your silver, platinum, and PGM metals and impurities, making it an easy way to boost customer confidence and ensure dealer reliability.
-
product
Platinum RTD Sensor - PT100 - 3 Wire 1 meter long
For precision temperature sensing, nothing beats a Platinum RTD. Resistance temperature detectors (RTDs) are temperature sensors that contain a resistor that changes resistance value as its temperature changes, basically a kind of thermistor. In this sensor, the resistor is actually a small strip of Platinum with a resistance of 100 ohms at 0C, thus the name PT100. Compared to most NTC/PTC thermistors, the PT type of RTD is much most stable and precise (but also more expensive) PT100's have been used for many years to measure temperature in laboratory and industrial processes, and have developed a reputation for accuracy (better than thermocouples), repeatability, and stability.
-
product
8 Channels, RTD Measurement
RT1
The module provides 8 measurement channels, and can be programmed for interfacing to 2, 3, and 4-wire platinum RTD sensor configurations. The 4-wire mode (default) is the most accurate, providing excellent stability and repeatability. The RTD channels feature individual A/D converters and precision excitation/current drive. Programmable lead-wire compensation is provided for inherently less accurate 2 and 3-wire configurations. All RTD channels are self-aligning because each channel is automatically "aligned" on a rotating basis to eliminate offset and gain errors throughout the operating envelope. Programmability for expected resistance range and wire modes allows for optimization of scaling/resolution, as well as flexibility in reading many RTD types.
-
product
Solar Panel Reach-in Chambers
ENX48Solar Panel Reach-in Chambers
Your first choice for a medium-size test chamber for PV module testing is ESPEC's ENX48.These models provide a variety of performance capabilities to meet maximum or minimum change rates in IEC or UL test standards. Incorporated are the features of our smaller Platinum and Global-N lines. The refrigeration systems of these models utilize modern, high performance scroll compressors that allow a small footprint while allowing unparalleled service access.
-
product
Counter Electrodes
For a system using a three-electrode potentiostat, we measured current when a potential is applied between the working electrode and the reference electrode. Passage of current through an electrical circuit requires electron transfer reaction between the working electrode and the counter electrode.The main function of the counter electrode is to provide the location of the second electron transfer reaction. Important parameter of the counter electrode is the surface area. It is required (area) large enough to support the current generated for the working electrode. For example, the surface area of the platinum electrode of 5 cm is sufficient to use as an electrode, such as steady-state cyclic voltammetry experiments. However, for generating a high current measurements such as bulk electrolysis, the counter electrode of a larger area is required, as Catalog No.012961 which the length of platinum is 23 cm. This electrode is used for measurement, such as rotating ring disk.
-
product
Climate Chamber
ICH
Its excellent temperature and humidity homogeneity positions the climate chamber ICH in the international top league of stability test chambers. Thermal transfer to the interior whether heat or cold is guaranteed through a large-area air jacket on four sides. Thanks to its hermetically sealed interior, the climate chamber ICH does not consume any water once the setpoints have been reached, provided that the door is not opened. Two high-grade platinum temperature sensors with mutual monitoring guarantee interruption-free long-term operation even if one sensor should fail.
-
product
Dual MAX31865 PT-1000 RTD to Digital Breakout
SEN-30202-PT1K
Dual channel breakout board for the MAX31865 RTD-to-Digital converter from Maxim. Two breakout hardware configurations are available standard, designed to interface with either the PT100 or PT1000 platinum RTDs. For non-standard applications, including thermistors, custom hardware configurations can be accommodated. Contact Technical Support for more information.
-
product
16-Channel VME RTD/Resistance Input Module
V410
The V410 is a 6U VME module that provides sixteen independent analog inputs that may be used to read RTDs, thermistors, and other similar resistive sensors. It can also read cryogenic diodes. Users may set input range and adjust other settings at VMEbus speed, and depending on the range selected the microprocessor will do the necessary calculations and output voltage, resistance, or temperature. Temperature conversion is available for 100Ω and 1000Ω, series 385 and 392, platinum RTDs.
-
product
TDS Testers
Labodam TD testers are equipped with platinum sensors, providing fast and reliable measuring results. Easy to use and featuring a waterproof design, these instruments are protected against harsh conditions and can be used to measure total dissolved solid content present in drinking water, waste water, swimming pool, and aquarium water.
-
product
Probes/Sensors
Fluke Calibration provides high-quality secondary platinum resistance thermometers (PRTs); industrial PRTs; high-temperature, fast-response, and other special-application PRTs; thermistor standards; secondary thermistor probes; type R and type S thermocouples. These probes may be used for temperature measuring, temperature calibration, temperature monitoring and temperature validation.
-
product
Cross Flow Cell
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
product
Grid Electrode
Grid electrode is produced by the deposition of the platinum, gold or carbon onto the quartz glass. The dimension of the glass is 8 x 27 mm, with a 1 mm of the thickness, and the grid line is 100 m width with a distance of the 150 m between lines.
-
product
High-Precision Thermometer
The high-precision thermometers from Anton Paar are designed for the most accurate temperature measurements, comparison calibrations and fixed point calibrations in industry, laboratories and research. Combined with calibrated platinum resistance thermometers, Anton Paar's thermometers achieve a measuring uncertainty of 10 mK or less.
-
product
Environmental Test Chamber
The chamber is produced by SUS304 Steel, the temperature keeping material is produced by Polyurethane hard foam and ultra-fine fibre glass, the doorframe heat insulated by Double high temperature aging silicone rubber door sealing strip.The temperature controller is used by Korean TEMI display in English/Chinese and German Siemens PLC, it can be communicated to PC via RS-232. The temperature accuracy is 0.1 and humidity is 0.1%R.HThe temperature sensor is platinum PT100 Ohms/MV resistor
-
product
Temperature Probe, 100 ohm, RTD, Surface
8695A
100 platinum, surface probe is designed specifically for temperature measurements on hot or cold flat surfaces such as industrial furnaces or restaurant grills.
-
product
Temperature Probe, 100 ohm, RTD, Air/Gas
8696
Model 8696, platinum RTD probe is designed for measuring air and other gaseous mediums. The sheath is 8" long and is constructed with #304 stainless steel. The probe tip is protected from temperature fluctuations by a perforated shield. The probe''s 4-inch handle is connected to a thermoplastic coil cord that extends from 1-1/2 feet to 5 feet.
-
product
Tracking Index Test Apparatus
CX-L19
Shenzhen Chuangxin Instruments Co., Ltd.
It applied with rectangle size of platinum electrode, each electrode can force to the sample is 1.0±0.05N. Electrode Distance: 4.0mm±0.01mm, included angle: 60°±5°. Electrode Voltage: 100~600V, (48~60HZ) adjustable, when the short-circuit current at 1.0±0.1A, the voltage goes down less than 10%. The liquid drop device can make the liquid height from 30~40mm (adjustable), drops liquid size is 44~55 drops/1cm3. The interval drops of liquid is 30s±5s (adjustable). During the testing, the short-circuit current is more than 0.5A to keep 2 seconds, then shut off current, it show the sample not pass. Inside dimension: 0.5CBM and outside dimension: 630mm*390mm*750mm.
-
product
Micro Melting Point Instrument
DRK8026
Shandong Drick Instruments Co., Ltd.
Determine crystal melting point of the substance to make sure its purity. Mainly used for determining the meltingpoints of medicine,dyestuff,spice and other organic crystal compounds.Using photoelectric automatic detection, Dot matrix LCD display picture technology, digital keyboard input, and has the initial melting, final weld automatic display,automatic recording of melting curve, automatically determine the melting point of the mean value function. The temperature system uses highly linear platinum resistance as detection elements and PID regulation technology, improved the melting point’s precision and reliability. The instrument establishes communication with PC through the USB or RS232, printing or saving the curve and it uses capillary Pharmacopoeia as sample tube.