Filter Results By:
Products
Applications
Manufacturers
Resistance Meters
measure opposition to electrical current.
See Also: Resistance, Resistivity, Resistance Standards, Resistance Test, Resistivity Meters
-
product
Transformer Winding Resistance Meters
TWA Standard Series
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
product
Transformer Winding Resistance Meters
TWA Advanced Series
The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
product
Resistance Meters
ACL provides surface resistance/resistivity meters and digital megohmmeters to quickly and accurately measure resistivity.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
product
Winding Resistance Meters
The NMC 'TDR' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. 'TDR' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. 'TDR' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.
-
product
Insulation Resistance Meters
Scientific Mes-Technik Private Ltd
General purpose insulation resistance meterAnalog indicator, High measurement speedTest voltage range: 10 V to 500 VSuitable for Test capacitor insulation testEasy operation
-
product
Circuit Breaker Contact Resistance Meters
Vanguard Instruments Company, Inc.
The Vanguard Auto-Ohm 10 is a 10-ampere battery powered micro-ohmmeter designed for low-resistance-measuring applications such as the measurement of resistance in circuit breaker contacts, bushing contact joints, and welding joints. The unit is powered by four 3400mAh, 3.7Vdc Li-Ion rechargeable batteries. With these high capacity batteries, up to 2,900 tests per charge (10A/2 second duration) can be performed in the field.
-
product
Transformer Winding Resistance Meters
RMO TD Series
The RMO-TD Series On-Load Tap & Winding Resistance Analyzer is designed for the measurement of winding resistance of inductive elements, and for tap changer analysis. The RMO-TD series is based on the latest technology, using the most advanced switching technology available today. The RMO-TD series is accurate (0.1%), powerful (up to 60 A) and lightweight. It generates true, ripple-free DC current with automatic metering control and a discharge circuit.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TT Series
RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
product
Resistivity Meters
SSR-MP-ATS
Integrated Geo Instruments & Services Private Limited
The instrument design incorporates several innovative features and advanced techniques of digital circuitry to make it a reliable Geophysical tool providing high quality data useful for mineral and groundwater exploration and any other Geophysical applications. The SSR-MP-ATS sends the entire current into the ground without wasting power for constant current generation thus increasing the signal strength to probe deeper layers.
-
product
Winding Resistance Meter 15Amps, 2 Channels Rack
WR14R
Raytech Digital Winding Resistance meter WR14 R is the rack mount version of the WR14. They are designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
product
Contact Resistance Meter
CRM 200B+
CRM directly measures micro-ohm values at 200A DC under live EHV switchyard conditions quickly & accurately. It is specially designed to reliably measure micro-ohm contact resistances of Circuit Breakers, Isolators, Busbar joints, earth switch joints, welded joints etc., under the hostile electrostatic noise found in live EHV switchyards up-to 765 kV. SCOPE’s ability to make electronics work in such environment enables CRM to measure mili-volts signal in the presence of kilo-volts noise.
-
product
Earth Resistance & Resistivity Meter (for 50Hz mains)
MRU-120
* earth resistance measurment with 3-pole,4-pole method, * earth resistance measurement without disconnecting measured earths (using clamp), * continuity of equipotential bondings and protecting conductors * two clamps earth resistance measurement without auxiliary test probs, * earth resistivity measurement,
-
product
Resistance Meter
MT8-4L
М-module МТ8-4Л is a mezzanine module designed to measure the resistance of resistive sensors using a four-wire measurement circuit in eight channels (eight-channel digitizer). М-module МТ8-4Л is installed on the carrier of mezzanines - module НМ-М and is connected to it via a local information highway. Up to four m-modules of various types can be installed on the NM-M module. The NM-M module, together with the m-modules installed on it, forms a VXI module of size C-1 and is used to create information measuring VXI systems.
-
product
Concentric Pen Probe
807
This miniature concentric ring probe allows for small areas to be measured for surface resistance in accordance to ANSI/ESD STM11.11-2006 when connected to a resistivity meter or megohmmeter.
-
product
Winding Resistance Meter
TRM 104
TRM104 is a portable winding resistance meter, designed to work in live EHV switchyards. Winding resistance values of large transformers up to 500 MVA and rotating machines are directly displayed. The meter is protected against the back emf offered by large inductive winding. A back-lit 4 line LCD with a user-friendly menu sets up the instrument for the test. Winding resistances and safety messages are also shown on this display. It is possible to measure the resistance of two windings simultaneously.The meter contains a special power source for rapid stabilization of test results.
-
product
Winding Resistance Meter
TRM 25
SCOPE introduces 25 A state of the art precision winding resistance meter, specially designed for field testing as well as factory testing of large transformers up to 500 MVA. Winding resistance value of transformer and rotating machine are directly displayed on 5.7” TFT display. TRM 25 is designed to work in live EHV switchyard conditions, ensuring operator’s safety and repeatability of results. Maintenance time saving is ensured by one time connection to transformer with simultaneous resistance measurement of three / six windings, measurement of resistances of all taps with automated tap change and demagnetization facility. The meter is protected against the back-EMF offered by large inductive windings.
-
product
Insulation Resistance Meter
AMIC-5005
Insulation resistance measurement - 15TΩ: * 50 - 1000 V, in 10 V steps, * 1000 - 5000 V, in 25 V steps ; Memory of 999 results and transmission to PC ; Measurement of AC and DC voltage and capacity ; Measurement of leakage current ;Function with digital filter
-
product
Contact Resistance Meter
CRM 200B
CRM 200B directly measures micro-ohm values at 100 Amps DC under live switchyard conditions.CRM 200B is specially designed to reliably measure contact resistance of circuit breakers, isolators, busbar joints, welded joints etc., under the hostile electrostatic noise found in live EHV switchyards upto 765 kV.
-
product
Floor Resistance Test Kit
PMK-152
The PMK-152 Floor Resistance Test Kit contains the instruments you need to take resistance measurements.The PMK-152 includes Prostat's PRS-812 Resistance Meter with 5 pound conductive rubber electrodes. You can take measurements at 10 and 100 volts with accuracy within ±5%.
-
product
Winding Resistance Meter 50Amps, 3 Channels
WR50-13
Raytech Digital Winding Resistance meter WR50-13 is the enhanced version winding resistance system with a most advanced demagnetizing circuit. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
product
4 2/3 Digital Resistance Meter (1/32 DIN)
CS3-RS
CS3-RS Resistance Indicator has been designed with high accuracy, display, control, remote communication.A compact body design for small equipment, laboratory instrument, and others.Also are available with relay output, analog output, RS485 Modbus RTU communication to cover a wide range of applications.
-
product
Winding Resistance Meter 15Amps, 2 Channels
WR14
Raytech's Digital Winding Resistance meter WR14 is the battery powered version winding resistance system with a most advanced demagnetizing circuit. It is designed for high degree of accuracy measurement of very low resistance of any inductive loads.
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
product
4 2/3 Digital Resistance Meter
CS2-RS
CS2-RS Resistance Indicator has been designed with high accuracy measurement, display and communication of Ohm (2 wire) as like as Coil of motor or transformer.The meter supports Field Calibration function. It can be calibrated with sensor (Resistance) to meet machinery structure.We build flexible function as like as 3 bank (for multi-range scaling and set point) and 3 external control inputs meet to various testing equipment inquiry.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments applications.
-
product
Earth resistivity meter
16GL-N
Last release of a very popular family of earth resistivity meters, this 16 bits geoelectrical instrument represents a really performing and affordable solution for Vertical Electrical Soundings at medium and great depth. Reliable and lightweight, 16GL-N is characterized by really first-rate performances, even if it remains extremely easy to use. The possibility to download data through USB enables a quick interpretation with the data inversion software. It is recommended, as to exploit its capabilities, to use it in conjunction with one or more P-100-N rechargeable accumulators.
-
product
DIGITAL DC RESISTANCE METER
VE2516BU
Micro Processor based DC Resistance Meter with PASS / FAIL indication.
-
product
Syscal R1 Plus Switch
The SYSCAL R1 Plus resistivity meter is specifically designed for medium-depth exploration. It combines a power source, transmitter up to a 200W or 1200Vpp output voltage, and a 2 channels receiver in a single unit; its compactness makes it an effective tool for intensive resistivity surveys.