Filter Results By:
Products
Applications
Manufacturers
- Virginia Panel Corporation
product
SIM, Module, ITA, 90 Series, Fully Loaded with pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106)
510171102
This fully loaded SIM module kit comes with 34 pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106). This kit also includes two PCB brackets for securing module to PCB.
-
product
Transformer ON-Load Tap-Changer Tester
WAYZ-2011
Wuhan Sangao Electrical Test Installations Limit Co.
This Transformer on-Load Tap-Changer Tester is acc to Chinese Electric Power Industry Standard, It also can meet the requirement of electrical equipment handover and prevention test standard.To achieve the accurate measurement of on load tap changer's transition time, transition resistance,three-phase synchro nization parameterssyn.It is the best test equipment of on-Load Tap-Changer.
-
product
Multiple Gas Transformer DGA
MULTITRANS
The MULTITRANS is an 8-gas on-line transformer DGA monitoring unit designed to monitor a bank of three single-phase transformers in close proximity. Based on the same core technology as the highly successful TRANSFIX the MULTITRANS measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm).
-
product
8-Gas On-Line Transformer Gas Analyser
TRANSFIX
The TRANSFIX is an 8-gas on-line transformer DGA monitoring unit. Using specially developed advanced photo-acoustic detection technology, the TRANSFIX measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm). The measurement of these gases allows the user to detect and diagnose a complete range of transformer faults.
-
product
Fiber Optic Temperature Sensor with the EasyDisk
The TPT-62
The TPT-62 fiber-optic temperature probe family employs industry standard 62.5µm core OM1 fiber optic for highly improved optical, mechanical, and reliability properties over legacy 200 µm core (1st generation) fiber optic sensors. The EasyDisk sensor tip assembly ensures IEC60076-2 (Annex E) compliant installation and enables quick insertion of the probes into the spacers within the windings of transformers.
-
product
Environmental Test Probe, Temperature
72-8364
Type K Surface Temperature Probe Surface probe is ideal for flat stationary surfaces such as molds, heating elements, integrated circuits, transistors and transformers. Very low sensor element mass enables fast response measurement time. Type K thermocouple temperature probes are commonly used with all types of industrial temperature controls and measurement equipment, and are compatible with Tenma handheld thermometers and digital multimeters that include temperature function. All are terminated with standard Type K plugs. See the complete line of Tenma Thermocouple Probes and Accessories
-
product
Standard Voltage Transformer
HJ / 635
Wuhan Huatian Electric Power Automation Co., Ltd.
It is mainly designed for the voltage transformer calibration standard of basic power supply and production department.
-
product
Instrument Transformer
Our company has achieved a reputed niche in international market by manufacturing and exporting a great range of Instrument Transformer. Widely used in electrical, power generation and engineering sector for transforming voltage or current level, this equipment is in accordance with industry standards. Manufactured using excellent grade raw materials sourced from reputed vendor, Instrument Transformer is offered to clients in different technical specifications. We stringently test this instrument on varied standard parameters.
-
product
Analog Power Supply
Type NPS-2412
National RF's Type NPS-2412 analog power supply was designed to be used in communication equipment where radiated switching inverter noise from conventional “switching type” supplies is not acceptable. The power supply consists of a standard rectified transformer output driving a pair of voltage regulators and filtering networks. The 2412 offers an adjustable voltage output between 2 and 24 volts as well as a fixed voltage output of 12 volts. A maximum of 20 Watts of DC power can be supplied from the unit. As the voltage regulators dissipate power in the regulation process, the power to the load is derated accordingly, dependent on the set voltage to the load. The adjustable regulator is a standard LM-317T integrated circuit device. The fixed regulator is a standard LM 7812 device. Upon customer request, the LM 7812 device may be changed to any voltage rating within the the LM-78xx series of regulators. Contact National RF for this modification if desired.
-
product
Test Switches
Series FT
An industry standard for CT & VT isolationfor instrument transformer and connected device testing.Up to 10 poles; Numerous configurations availableTypically mounted on switchgear and relay panels10 pole test plug available; UL and cUL recognized.
-
product
LVDT Sensor Amplifiers
Analog Devices signal conditioning ICs, together with linear variable differential transformers (LVDTs), can be used to convert mechanical position to a dc voltage. The IC provides both the excitation for the LVDT and the output conversion to dc level with a user selectable gain. ADI LVDT signal conditioners are available to interface with a wide range of LVDTs, including half bridge and standard 4- and 5-wire.
-
product
Turns Ratio Testers
TRT Standard Series
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
product
Embedded Synchro - Resolver -
LVDT I/O Cards
Computer Conversions Corporation
100% Transformer Isolation is offered for all AC I/O, and various Isolated DC converters are available as standard product, eliminating concerns for ground-loops, ground interjected (intermittent and ghostly) field noise, inductive surges, differing potentials, and high voltage field transients from effecting the card itself, the sensitive ISA bus backplane and any other device or system sharing these signals.
-
product
High Voltage Impulse Test Set Up
We are renowned as the foremost manufacturer and exporter of High Voltage Impulse Test Set Up. This testing equipment is demanded in electrical, power generation and engineering sector. It is incorporated with fiber optic isolated digitizers to test various types of transformers. We utilize excellent grade raw materials to engineer and develop this High Voltage Impulse Test Set Up in accordance with industry standards. Our clients can get this equipment from us at competitive price.
-
product
Insulating Oil Dielectric Loss Tester
HDLT
Hention Electrical Equipment Co., Ltd.
This integrated precious insulation oil dielectric loss tester is for measuring dielectric loss TAN and capacitance of transformer insulation oil.This is a high precision instrument; integrated with oil cup, temperature control instrument, temperature sensor, dielectric loss test bridge, AC test power, and standard capacitor, etc.
-
product
Autotransformer
T-1007
The Titan Series T-1007 Auto-transformer is used to conveniently scale the standard OV to 130V / 260V full scale Titan AC Power Source/Frequency Converter output to either X .5 stepdown (OV to 65V) or X2 stepup (OV to 520V). It has a 1.2 KVA power rating with excellent bandwidth and voltage regulation.The unit is of toroidal design, making it approximately half the size and weight of a comparable stacked laminate transformer. It is center filled with epoxy for isolation and durability, and features simple 1/4" bolt center mounting.
-
product
Transformer Winding Resistance Meters
TWA Standard Series
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
product
Transformers/Baluns
Macom Technology Solutions Holdings Inc.
At MACOM we offer multiple industry standard transformers used in wireless, aerospace and defense and communications applications. Available in a variety of surface mount, flat pack, and connectorized packages, our transformers and baluns are available in balanced and unbalanced versions and are characterized as 50 and 75 ohm impedance devices. Working closely with system design engineers to meet custom specifications, our proven technological expertise and innovative high quality, low cost manufacturing capabilities makes MACOM the partner of choice for some of the world’s leading infrastructure companies.
-
product
Partial Discharge Test Set
We are an unparalleled name in the industry, engaged in manufacturing and exporting Partial Discharge Test Set that is broadly used for instrument transformers to test the discharge of voltage. This test set is manufactured in compliance with set international quality standards using optimum quality components under the observations of our experienced professionals. Further, it is made available in several specifications to meet the exact requirements of the clients. Our offered Partial Discharge Test Set can be owned from us at nominal prices.
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.
-
product
Detection of PtG and PtP Faults on Multi and Single Core Cables
CableTroll 2350
CableTroll 2350 is an indicator for detection of PtG and PtP faults on multi and single core cables. The unit uses standard type current transformers. (40:1, 60:1 or 3x500:1)
-
product
ANSI Potential Transformer Burdens
The ANSI Potential Transformer Burden Model PB-96-ANSI is designed for loading the Voltage transformers during accuracy tests as per ANSI standard C57.13. The PB-96-ANSI is a dual input ANSI burden providing the inputs of both 120V & 69.3V. It can be used along with the ELTEL Automatic Instrument transformer Test Set. AITTS-98 to test VTs as per ANSI standards.
-
product
Aging and Life Test Rack
SY2036
SY2036 Aging and life test rack is fully designed according to the IEC standard, and can also be designed based on the customer request. SY2036 can test LED, CFL, HID Indoor lamp and Outdoor lamp. Input Power supply: AC220V, 50/60HZ, 12KVA Min (110V is option) • Built-in transformer: 0-250V 5KVA and 0-300V 5KVA (Other power is option) • Maximum power for EUT: 5KVA and 12A (Other power is option) • EUT and Number: 112pcs B22, 112pcs E27. 36pcs T5/T8/T12 Tube. 32pcs LED panel (Other EUT can be designed according to customer request) • ON/OFF test: Can be set on the touch screen with program • Test number: 0~99999(Adjustable)
-
product
903 Benchtop Three Phase 40A
Weshine Electric Manufacturing Co., Ltd
1. The instrument has standard four phase voltage and three-phase current output. It can test not only various traditional relays and protection devices, but also various modern microcomputer protections, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. Classic Windows XP operation interface, friendly man-machine interface, easy and fast operation; high performance embedded industrial control computer and 8.4 inch resolution 800 × 600 TFT true color display screen, can provide rich and intuitive information, including the current working state of the equipment and various help information.
-
product
SAE AS5643 Mil-FireWire PXI Express Test & Simulation Instrument
HSSUB-6120
Avionics Interface Technologies
Highest density capability available in an AS5643 3U PXI Express, single slot instrument - Four (4) FireWire nodes, each with three (3) ports - Apps provide high-level (AS5643) and low-level (1394) access, while accommodating end-user customization - S100, S200, S400, S800 transfer rates - Support all Nodes operating concurrently at 800 Mbps - Independent transformer coupling for each port - Eight (8) standard PXI backplane triggers - Industry standard Texas Instruments IEEE 1394b Chipset - ANSI C (typical), C++/C#/LabVIEW
-
product
Electronics & Power
Excelitas Technologies offers a wide range of high-performance electronics, power and energetics technologies to drive your most demanding photonic systems. Our Electronics & Power offering includes Capacitor Chargers, Spark Gaps and Transformers, High-Voltage DC Power Supplies and Atomic Frequency Standards. Our Energetics portfolio includes Electronic Safe & Arm devices, Detonators, Ignition Safety devices, and Rocket Motor Initiators.
-
product
Force Tensiometers
Sigma 702ET
The Sigma 702ET Transformer Oil Analyzer has been specifically designed to guide the user through the measurement of interfacial tension of transformer oil according to relevant standards.
-
product
Precision Multirange Voltage Transformers
WP-36000
The WP-36000 Transformer is primarily a laboratory standard. The high degree of accuracy and multiplicity of ranges makes this transformer the standard for precision calibration work. With the aid of this transformer, very accurate determination can be made of the ratio and phase angle characteristics of voltage transformers having ratings from 14,400 to 36,000 volts.
-
product
5VA Reference Supply, DC input
PS5410C-16
The PS5410C-16 is a 5VA AC Reference Power Supply, available with many transformer isolated output voltages at different frequencies. Input power is either 12 VDC or 15 VDC. The standard 15 pin "D" connector simplifies interconnection to other equipment.
-
product
VOLTAGE TRANSFORMERS
Designing & manufacturing a range of high quality, voltage transformers in three different frame sizes for both measuring and protection duties. Transformers which are designed to comply with the requirements of IEC 61869-3 or other international standards as required can be supplied to satisfy most Low Voltage applications.
-
product
SF6 Filled High Precision Standard Capacitors
YL Series
Shanghai Jiuzhi Electric Co., Ltd.
The SF6 insulated standard capacitor is used as Capacitance standard in measuring bridge Circuits to measure the dielectric dissipation Factor tanδ of all types including cables, capacitors, bushings, instrument transformers and power transformers. Further-more, It can be used as high-voltage capacitor for voltage divider circuits of high-voltage transformer test.