Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI Differential Fault Insertion Switch Modules
Pickering's PXI Differential Fault Insertion Switch Modules support multiple channels of two-wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to externally applied fault conditions. *Two module types are available: Two wire fault insertion module suitable for CAN Bus and FlexRay.*High bandwidth two wire fault insertion module suitable for Gigabit Ethernet, AFDX and BroadR-Reach.
-
product
Temperature Transmitter Outdoor, Indoor
T0110
Temperature transmitter with 4-20mA output for two-wire connection is built in a durable watertight case. Output temperature range is user adjustable. Degrees Celsius and Fahrenheit are user selectable. Large dual line LCD is an advantage. Display is possible to switch off.
-
product
High Density Multiplexer Module
1260-35
The Astronics 1260-35 is a high-density scanner or multiplexer, ideal for applications with large switching requirements. The 1260-35 can be user-configured in many ways, from a 1x96 two-wire to sixteen 1x6 two-wire multiplexers, switching up to 250 VDC and 1A per channel.
-
product
Advanced Power System – Power Dissipater Unit, 1000 W
N7909A
The N7909A power dissipater unit adds current sinking or two-quadrant operation to any Advanced Power System (APS) N6900A or N7900A power supply. Each N7909A provides up to 1 kW of current sinking capability to an APS power supply, so you will need two N7909As to achieve full two-quadrant operation of a 2-kW APS supply. You can use a single N7909A unit with a 2-kW APS power supply to achieve 50% current sinking capability. The N7909A form factor is 1U and full rack width. N7909A connects to an APS power supply via a two-wire power connection and a communication connection to provide continuous two-quadrant operation. The connections are located on the rear panel of both the N7909A and the supply.
-
product
Voltage Meter
МН32СМ
The mezzanine module (mezzanine) МН32СМ is designed to measure instantaneous voltage values over thirty two two-wire differential channels.
-
product
3 Wire (Analogue) Earth Resistance Tester
4105 ER
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
product
4 x 8 Two-Wire Matrix Module for DAQ970A and DAQ973A
DAQM904A
4 x 8 Two-Wire Matrix Module. 32 two-wire crosspoints with high switching voltage capability of up to 300 V and current capacity of up to 1 A.
-
product
Insulation & Multifunction Tester (LCD Display)
4167 MF
Standard Electric Works Co., Ltd
● High Quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Test test leads are supplied as standard accessories for simplified two-wire measuring system.● Two insulation test voltages(DC) : 250V and 500V.● Alternation voltage measurement.● Battery life indicator.● Fuse protected.
-
product
3 Wire (Digital) Earth Resistance Tester
1120 ER
Standard Electric Works Co., Ltd
● Waterproof: IP54● Capable of measuring earth resistance and earth voltage● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test● The test leads are supplied as standard accessories for simplified two-wire measuring system● 0Ω adjustment● Battery operated● Data hold function● Low battery indication
-
product
1x8 Multiplexer Plug-In
1260-138A
The Astronics1260-138A is an eight 1x8, two-wire scanner/multiplexer plug-in card for the Adapt-a-Switch® platform. It installs, easily and directly from the front panel, into the Adapt-a-Switch VXI Carrier, 1260-100.
-
product
3 Wire (Digital) Earth Resistance Tester
1820 ER
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.
-
product
Radar Level Transmitter
DR6500
The Drexelbrook DR6500 is a two-wire open air radar level transmitter for measuring level in applications with powder and dusty atmosphere.
-
product
Automotive Ethernet Channel Compliance Software
AE6910L
The Whole Communications Channel represents the complete wired connection between two transmit / receive modules with an automotive Ethernet interface using a two-wire twisted pair cable. The Keysight AE6910L software ensures signal quality requirements, with conformance testing for that channel. In addition, it performs return loss, insertion loss, mode conversion, and power sum cross talk measurements of a cable in a bundle.
-
product
3 Wire (Analogue) Earth Resistance Tester
1105 ER
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
product
3 Wire (Digital) Earth Resistance Tester
2720 ER
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.
-
product
Field-installation Type Simplified Fluoride Ion Concentration Meter(Two-Wire Transmission)
HC-300F
HC-300F is connected to a fluoride ion electrode (1009) to detect free fluoride ions in the sample water.(Total fluorine is not detected.) It is suitable for fluoride ion monitoring in effluent from factories, e.g., those of semiconductor FPD and glass manufacturers.
-
product
Current Loop Calibrator
LC-100
The Current Loop Calibrator an accuracy of 0.015% and a 0.001 mA resolution. The loop calibrator can simulate, power, and measure two-wire transmitters. With automatic Step and Ramp functions, the precision loop calibrator also enables remote calibration of 4-20mA devices.
-
product
Interface
RAR-PXI
Available in a range of configurations to match your needs, the RAR-PXI provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected two-wire, 32-bit protocols in a PXI compatible CompactPCI form factor.
-
product
Field-installation Type Electric Resistivity Meter (Two-Wire Transmission)
HE-300R
HE-300R connects resistivity sensor (ERF Series) and measures resistivity and temperature in the sample water.It is suitable for measurement of UPW resistivity.
-
product
4 x 8 Two-Wire Matrix Module for 34970A/34972A
34904A
The Keysight 34904A module for the 34970A/34972A Data Acquisition/Switch Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your DUT at the same time. Rows or columns may be connected between multiple modules to build 8 x 8, 4 x 16 or larger matrices, with up to 96 crosspoints in a single frame.
-
product
Field-installation Type ORP Meter (Two-Wire Transmission)
HO-300
HO-300 connects ORP sensor and measures ORP and temperature in the sample water. It is suitable for neutralization reaction treatment management of aeration tank, denitrification tank, etc.
-
product
Field-installation Type Electric Conductivity Meter (Two-Wire Transmission, For Low-concentration)
HE-300C
HE-300C connects conductivity sensor (ESH/FS Series) and measures conductivity and temperature in the sample water. It is suitable for monitoring pure water/boiler water drainage recovery control and inline measurement of pharmaceutical water conductivity according to USP<645> quality guidelines.
-
product
3 Wire (Analogue) Earth Resistance Tester
2105 ER
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
product
Combination SPDT/Multiplexer Module
1260-37
The Astronics 1260-37 contains 40 Form C (SPDT) switches and eight 1x6 multiplexers. The multiplexers can be expanded using the on-board jumpers to four 1x12, two 1x24 or one 1x48 two-wire channel.
-
product
ICP® Shock Accelerometers
Piezoelectric ICP® accelerometers afford a very high signal output (+/- 5 volts full scale) and the ease of two-wire electrical connectivity. Their inherent ruggedness enables them to be severely over ranged without damage. The addition of internal mechanical isolation minimizes the high frequency stress that would otherwise be encountered by their ceramic sensing elements. This mechanical isolation, coupled with an internal 2-pole electrical filter, built into the ICP® circuitry, tailors the overall accelerometer response to assure data quality to frequencies as high as 10 kHz. Depending on the specific model, accelerations in excess of 50 kg can be successfully measured. These modern designs, with their internal elastomeric isolation materials are verified through calibration to remain dynamically linear and are enabling piezoelectric accelerometers to operate in increasingly severe acceleration environments.
-
product
Digital Earth Resistance Tester
8020 ER
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Frequency : 820Hz.● 0Ω adjustment.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.● Simplified measurement probe is also provided for two-wire measuring method.
-
product
3 Wire (Analogue) Earth Resistance Tester
2705 ER
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Battery check function.● Calibration performed with supplied test leads.
-
product
192 X 4 / Dual 96 X 4, cPCI High Density Matrix Module
DP-cPCI-4149
Matrix switches are the most versatile type of switching system. Any input can be connected to any output, singly or in combination. A matrix switch simplifies the signal routing in an overall system, through reduced internal connection path.DP-cPCI-4149 offers ultra high density matrix in a single slot 6U sized cPCI module with flexibility to configure in the following ways:192 x 4 (Single- wire).Dual 96 x 4 (Single -wire).96 x 4 (Two-wire)DP-cPCI-4149 uses magnetically screened reed relays.
-
product
Isolation Amplifier
Mornsun Guangzhou Science & Technology
An isolation amplifier is an amplifier that provides isolation between the input and output of the circuits, including isolation between their associated power supplies. MORNSUN offers different types of analog isolation amplifiers, such as acquisition type signal conditioning modules, output isolation signal conditioning modules, two-wire loop power supply signal conditioning modules and signal isolators, etc. These analog isolation amplifiers feature excellent temperature drift characteristics of less than 50PPM/℃ across the entire operating temperature range of -40 ℃ to +85 ℃ and achieve isolation transmission, signal conversion (programmable for some models), HART communication, signal amplification, port protection and other functions. SIP, DIP, SMD and DIN Rail packages are optional.
-
product
40 Channel Single-Ended Multiplexer Module for 34970A/34972A
34908A
Use the Keysight 34908A module for the 34970A/34972A Data Acquisition/Switch Unit for the greatest density in common-low applications, such as battery test, component characterization, and benchtop testing. Each module switches 40 one-wire inputs. All two-wire internal measurements except current are supported. The module low connection is isolated from earth and can float up to 300 V.