Filter Results By:
Products
Applications
Manufacturers
Voltage Sensors
See Also: Voltage Transducers, Current Sensors, Voltage Calibrators
-
product
DC Voltage Sensors
DC voltage sensors monitor input voltages ranging from 3 to 500 volts DC with a trip point accuracy of up to 1% in airborne, military and ground power applications. Using internal electronic circuits to detect, monitor and/or sense DC voltage, DARE DC voltage sensors, monitors, and voltage sensing relays can open or close a circuit when a certain pre-set over or under voltage condition exists or the DC voltage falls outside the specified voltage band window.
-
product
Specialty Testers
Test Voltage from 120V to 600V AC/DCNon-Contact Voltage Sensor from 90V to 1000VTest Continuity & PolarityCase serves as prod holder for one-hand operationSelf-storing prodsSolenoid Sensing indicated by LEDs & VibrationErgonomic Soft PVC housing for comfort gripLED Spotlight Illuminates Work AreaBattery not Included (AAA x 1)
-
product
Ultimate AC Sensor
Our Ultimate AC Sensor is just that... the Ultimate in voltage detection. This sensor detects 50-1000 volts AC and features a visual and audio alert. Like all of our sensors, it does not react to static electricity and is designed for a CAT IV environment.
-
product
Full-Featured Data Acquisition with Isolation and High-Speed Measurement
EX1400 Series
The AMETEK VTI Instruments EX1400 Product family features the EX1401 and the EX1403A. The EX1401 adds isolation and high-speed measurement capability to the popular EX1000 Series of instruments, an advanced, full-featured data acquisition family designed to acquire precision data from temperature and voltage sensors. The EX1403A Precision Bridge and Strain Gauge Instrument sets a new standard for strain and bridge measurements, delivering the highest performance measurements possible while controlling overall test hardware costs. Browse each product below to learn more or request a quote.
-
product
Sensor Tester
*Connection facilities for DC 2-wire and 3-wire sensors, *Change in switching status signalled visually and acoustically, * 15 V operating voltage for sensors when using a 9 V block battery, * Switches off automatically when not in use, * Visual indicator for operating voltage, switching status and low battery
-
product
Soil Moisture Sensor
SoilWatch10
SoilWatch 10 is a soil moisture sensor which allows measuring relative water content in the soil. Our sensor does not have any exposed electrodes that usually corrode in resistive sensors. Whats more the reads will almost not drift over time or with temperature changes. Our sensor will give the same readings regardless of supply voltage. The sensor is weatherproof. It can be buried in soil for extended periods of time without adverse effects on accuracy or reliability. Designed to work with Arduino.
-
product
Powertrain ICs for ICE/HEV/EV
ST's powertrain ICs cover a variety of functions including voltage regulators, sensor interfaces, and load or motor drivers, which are the building blocks of typical Engine Control Units (ECU) found in a vehicle's main applications (engine management systems, transmission control systems, alternator regulators, etc.).
-
product
Light-to-Analog Sensors (Voltage)
Renesas' light-to-voltage silicon optical sensors combine a photodiode array, a non-linear current amplifier and a micropower op amp on a single monolithic IC. Applications for these devices include display backlight control, keypad dimming, anti-glare mirror systems, and industrial and medical light sensing applications.
-
product
AC Voltage Sensors
Continuously monitor single or three-phase power lines for over or under voltage conditions with DARE?s AC voltage sensors, voltage monitors, and voltage sensing relays. DARE?s complete line of AC Voltage Sensors will protect system equipment and circuitry from voltage that is hazardous or unsuitable for operation.
-
product
MicroLogPRO III USB Data Loggers
The MicroLog product line includes a range of low-cost, portable data loggers for supply chain monitoring, featuring internal temperature and humidity sensors with one external input for connection to temperature, current and voltage sensors. With over a decade of customer satisfaction, the MicroLog continues to offer application reliability for a variety of mission critical industries such as cold chain, healthcare, pharmaceuticals, and storage.
-
product
±6 kV ANSI/ESDA/JEDEC HBM Test System
HBM-TS10-A
High Power Pulse Instruments GmbH
*±6 kV Human-Body-Model (HBM) tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*Wafer, package and system level HBM testing*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*No trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT HBM current sensor for real time transient current monitoring with 1V/A output sensitivity into 50 Ω digital oscilloscope input*Integrated DUT HBM voltage sensor for real time transient voltage monitoring with 1/200V/V output sensitivity into 50 Ω digital oscilloscope input*Integrated overvoltage protection of the DUT voltage sensor, DUTcurrentsensor and DC test interface for efficient overload protection of the digital oscilloscope and SMU during high voltage HBM testing*Integrated DC test DUT switch with automatic switch control*Integrated 50 Ω precision hardware trigger output for high speed digital oscilloscopes*Fast HBM measurements, typically 0.5s per pulse including one-point DC measurement between pulses*Eficient sofware for system control and waveform data management (fully compatible with TLP measurement data)*The sofware can control automatic probers for fast measurements of complete wafers*Compact size 145 mm x 82.5 mm x 44 mm of the integrated HBM pulse generator probehead*System controller size 483 mm x 487 mm x 133 mm*High performance and high quality components*Optionally available hardware upgrades to all HPPI fully integrated HBM/HMM/TLP/VF-TLP test systems TLP-3010C, 4010C, 8010A, and 8010C
-
product
Cryogenic ICP® Accelerometers
Cryogenic ICP® accelerometers are specifically designed to operate at temperatures below the typical -65 ºF (-54 ºC) temperature limit of most voltage mode sensors. The use of specialized, built-in, cryogenic circuitry and quartz shear sensing technology promote survivability in demanding environments such as liquid nitrogen. Each sensor is hermetically sealed and individually tested to determine the thermal coefficient of sensitivity at -320 ºF (-196 ºC) ensuring reliable operation and accurate measurements. These sensors have been successfully used in the presence of liquid helium during structural testing of rocket boosters.
-
product
Integrated Board Power Management Functions For The Forward Thinking Engineer
Power Manager II
*Up to 12 differential voltage sensors with immunity to noise on ground plane*Voltage trimming to within 1%*Ruggedized CPLD with up to 48 macrocells for sequencing and supervisory signal logic*Large operating power supply range (3.3 V + 20% to 3.3 V -15%)*Up to 4 High-Voltage MOSFET Driver Outputs*Voltage Measurement with 10-bit ADC through I2C*Up to 8 On-chip DACs for Margining and Trimming
-
product
Primary Injection Test Set
PI-6000
The PI-6000 is a rugged & durable primary injection test set capable of testing circuit breakers up to 6,000 amperes frame size. It incorporates an output transformer with dual primaries to facilitate its use on power sources of 480 VAC as well as 208-240 VAC. The unit also includes dual secondaries to provide optimal impedance matching to a wide range of circuit breaker sizes. An internal voltage sensor automatically configures the AC control power section to be energized only when properly configured for the applied voltage.
-
product
Battery Monitor Relay
BMR
The Battery Monitor Relay contains over under voltage sensors combined with positive and negative ground detection.
-
product
Power Loggers/Energy Loggers
Designed for 50/60 Hz commercial line use 3 circuits (1P2W), single circuit (1P3W, 3P3W, 3P4W) Save data to the SD card continuously (Current) Clamp input (Voltage) Non-metallic contact sensor
-
product
Process Indicators & Field Devices
Field devices from the Field Analog series record and convert signals from resistance temperature detectors, thermocouples, resistance-type sensors, and voltage sensors directly on site.
-
product
AC/DC Split Core Current Sensor CT1000S
This AC/DC split core current sensor is designed for measuring large DC and AC currents in applications such as electric vehicles, renewable energy systems, inverters, and motors. It facilitates high-current measurements by clamping around existing current connections. With its voltage output, this sensor is compatible with power analyzers (WT series and PX8000) and waveform measurement instruments (ScopeCorders and DLM series), making it a versatile tool for various high-current measurements.
-
product
Non-contact Io/Ior Leakage Clamp Meter
MCL-800IRV
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Safety by non-contact sensor, not touching live part directly (prevention of electric shock, short-circuit, etc.).・Easy to carry and operate, clamp CT + display part integrated type.・Measurable line current + leakage current + resistive leakage current by one unit.・Available direct voltage input at live part as ordinary.・Calculable insulation resistance value(MΩ)by voltage & current (only in case of using direct voltage input sensors)・Available measurement for 3P/4W star connection.
-
product
Sensors
ZES ZIMMER Electronic Systems GmbH
Current sensors of PCT series and the voltage sensors of the HST series are carefully tested, adjusted and calibrated prior to shipment and are subject to strict quality controls.
-
product
Station Of Acceptance Testing
The acceptance test station consists of a personal computer - the workstation of the operator of the testing station, contact mechanisms, as well as current and voltage sensors. The station allows to test up to 10 electric motors of various types simultaneously. The operator of the testing station indicates the test sites at which the engine tests will be conducted, their type (from the database), serial numbers and a set of tests.
-
product
Surge Tester (Impulse Winding Tester)
SS6815 / SS6815F
Surge testers (impulse winding tester) is used for testing and check the insulation grade of turns between turns, insulation grade of layers between layers, insulation grade of windings between turns. It is used widely for transformer, current sensor, voltage sensor, relay, contactor, inductor, motor, generator, valve coil, voice coil, etc.
-
product
16-Channel RTD Signal Conditioning Card
ProDAQ 5821
The ProDAQ 5821 series of Signal Conditioning Cards is designed to interface with a variety of sensors, principally RTDs, Thermistors, Cryogenic Diodes and Voltage type sensors. Each version of the 5821 provides the capability of precise 4-wire measurement. In order to achieve this, a precise 500μA constant current source is provided per channel. The current source can be disabled on a per channel basis and is monitored to ensure that current is flowing. The value of the output current is stored on-board after calibration. In order to achieve the highest accuracy the output current may be automatically calibrated 'on-the-fly' using the ProDAQ 3416 24-bit Sigma-Delta ADC card and an on-board precision resistor.
-
product
Phasing Voltmeter/Sensor (2 in 1)
STB Electrical Test Equipment, Inc
STB unit replaces 3 separate units manufactured by competitors - line phasing, capacitance phasing and line to ground Versatile, lightweight and easy to useEach portable meter has a single rangeMeter usage: Voltage detection and phasing at capacitance test points or voltage detection and phasing on bare energized conductors (overhead & underground)Probes can be separated to be used as a voltage sensor or capacitance sensorFive position selector.
-
product
Multi-Channel PD System Locator
PDiagnostic Series
Power Monitoring and Diagnostic Technology Ltd.
The PDiagnostic is a portable system that utilizes Ultra-High Frequency (UHF), Acoustic Emissions (AE), High-Frequency Current Transformer (HFCT), and Transient Earth Voltage (TEV) sensors to detect, analyze, and locate the PD signals in real time for a multitude of medium and high voltage electric power equipment.The multi-channel PDiagnostic system locates PD on power equipment down to a meter by utilizing Acoustic-Electromagnetic Combination Location Technique, Time Difference of Signals’ Arrival (TDOA), Partial Discharge Signals Separation (PDSS), and 3D Positioning Technology with PC software included.The system features advanced PD diagnostic capabilities, automatic PD type pattern recognition, and accurate PD location capabilities. The PDiagnostic is an ideal trouble-shooting tool for your PD programs. Severity is determined and maintenance suggestions are provided accordingly.
-
product
Galvanic Isolation Amplifier
X005 Series
The X005 Galvanic Isolation Amplifier provides a regulated and resistively limited +5V dc power supply required by the sensors, it can be connected in three or five wire modes. Used in five wire mode positive and negative sense inputs enable the X005 to dynamically adjust the sensor supply thus ensuring the correct voltage across the sensor. Connected in this way the X005 can compensate for 15 conductor resistance. The sense terminals are linked internally so the end user can use the X005 in three wire or five wire mode without the need to fit or remove external links.
-
product
Pressure Sensors
The output voltage of this sensor changes with absolute pressure. An internal amplifier creates a single-ended, amplified output in the 0 to 5 Volt range, so the sensor can be connected directly to most control units. The body and diaphragm are impervious to chemical attack by standard motorsport fluids.
-
product
Line Mounted Fault Indicator
LineTroll 110Eμ
Linetroll 110E contains magnetic and electric field sensors surveying line current and line voltage. The magnetic sensor automatically adapts to line current, detecting preset current increases. The electric field sensor is monitoring the presence of line voltage. The sensor signals are processed and compared with user set alarm criterias.
-
product
PID Testing Equipment
The potential induced degradation (PID) is addressed with the standard IEC TS 62804-1. The standard defines two methods that enable analyzing occurring PID effects in a specific PV module type. PSE AG offers the necessary equipment for the test in a climate chamber. The test equipment can work with any climate chamber on the market and is delivered turnkey. It comes with all necessary equipment, high voltage power sources, sensors, data acquisition and software.