IBEKO Power AB
Our goal is to always keep providing the world market with the most advanced test solutions for transformers, circuit breakers and batteries
- +1 800 599 8113
+46 70 0925 000 - +46 8 731 77 99
- sales@dv-power.com
- Box 1346
Lidingö, 181 25
Sweden
-
product
Motor Winding Ohmmeter
RMO-M Series
The motor/generator winding resistance test is used to identify open windings, shorts between two windings, short to grounds, connection mistakes or shorted turns. This non-invasive test of winding resistance helps to pinpoint problems regarding windings in stator or rotor part of an electrical machine. Additionally, motor winding ohmmeter has the capability of performing heat run test which will show a change in windings resistance with an increase of temperature.The RMO-M series is designed as an ideal aid in preventive maintenance of electrical motors and generators. They are powerful (up to 100A of test current), portable (8 kg) and generate DC current which is completely ripple-free. This makes measurement very precise with 0,1% accuracy.Three voltage channels make measurement very easy since it is possible to obtain a value of all three winding resistances in one measurement
-
product
Battery Test Equipment
Improper functioning of battery systems installed in utilities, power plants, telecommunication systems, industrial applications and etc., can cause severe failures of the supported equipment and loss of critical information. Therefore, the battery test verifies their actual SOC (State of Charge) or SOH (State of Health) and prevents unwanted scenarios which could result in a significant budget loss as well as endanger of human lives.DV Power battery test equipment is able to perform the following battery measurements, using BLU and BVR devices:- Voltage (String and Cell)- Capacity- Temperature- Density of electrolyteAll of the above-mentioned measurements are performed with the highest accuracy. The advanced DV-B Win PC software enables collecting both numerical and graphical results. These features provide an easier and more efficient analysis. After the test, DV Win software generates a test report with a single click. A user can easily customize the report and save it in different formats, such as CLS, PDF, Word, or RTF.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
product
Circuit Breaker Analyzers & Timers
CAT Standard Series
Circuit breakers are being tested during manufacturing, commissioning or maintenance stages. The most basic test requires timing measurement using circuit breaker timer. Their primary role is timing and motion measurement of medium and high voltage circuit breakers. Devices from CAT Standard series have suitable application in:electric power generation,distribution system,part of the electric power transmission system,contractors testing,and industrial environments.CAT Standard series meets the requirements of an easy to use circuit breaker timer and analyzer with an attractive price. Furthermore, they are portable and lightweight (weighs only up to 7 kg). Finally, the plastic case is unbreakable and has IP67 protective rating when the lid is closed.CAT Standard series includes five models:Three circuit breaker timers – CAT03, CAT31, and CAT61Two circuit breaker analyzers – CAT34 and CAT64CAT03 is a basic model intended only for timing measurement of main contact operations on the circuit breaker with one break per phase. Unlike CAT03, CAT31 has the possibility of circuit breaker operation initiation, coil current measurement, and auxiliary contact timing measurement. CAT61 differs in comparison to CAT31 by its ability to measure up to two breaks per phase.CAT34 and CAT64 are more advanced compared to CAT31 and CAT61, respectively, since they have additional analog channels. Also, they have the possibility of a travel curve recording.A user can download the test results to a USB memory stick or save it to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Optional thermal printer prints test results in tabular and graphical form on 80 mm (3.15 inch) paper rolls. CAT Standard series instruments are compatible with DV-Win software. It provides full control of all CAT functions from a PC, as well as acquisition and analysis of test results.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
product
Battery Chargers
BAC Series
Battery charger BAC series is a portable and universal battery charging solution. It is primarily intended for charging Lead-Acid, Ni-Cd and Li-ion batteries from 1 V DC to 300V DC level. However, the unit can charge the string of any battery type by one of the available charge modes:IU (constant current + constant voltage)UU (constant voltage + constant voltage with a current limit)Charging modes provide a safe regulation of charging procedure and achieves fast recharge and low risk of overcharge.Variety of implemented protections, such as thermal, overcurrent, undervoltage, and overvoltage, assure the charging process will be safe for the battery and the instrument itself.A user doesn’t have to switch off the main charger in order to use BAC series charger. Just the opposite, the BAC series charger should support the main charger to speed up the process. An alternative use is to quickly recharge a battery following a discharge test.The provided display enables users to monitor all relevant information during the charging process and to adjust charging parameters and limits in real-time.The instrument offers the best power-to-weight ratio in the market, weighing only 10 kg / 22 lbs with the maximum output power of 2,7 kW.The maximum charging currents for lead-acid, Ni-Cd and Li-ion batteries, at various battery voltages, are presented in the brochure.
-
product
Circuit Breaker Analyzers & Timers
CAT Handheld Series
When it’s not practical to use conventional robust circuit breaker analyzers, a handheld circuit breaker analyzer and timer may come handy. DV Power has developed a unique CAT Handheld series. It is specially designed for testing of circuit breakers with one break per phase. Their compact and ergonomic design can provide a wide range of features and reliable operations in low, medium and high-voltage substations or in industrial environments.CAT Handheld series consists of two models, CAT-P and CAT-H. Both of them have a large (5,7 in) colored touch screen display. Because of that, test results are visible in dark places as well as in bright sunlight.Powerful internal Li-Ion battery of the instruments can last up to 8 hours of testing without recharging.CAT Handheld series records:main contacts operating times,contact synchronization,sequence time,a resistance of pre-insertion resistors,open and close coil currents,main contacts bounce time,auxiliary contact time,DC Voltage.Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by triggering signal from current clamps connected to circuit breaker coil.CAT-H is capable of performing a coil control, while this feature is optional at CAT-P instrument. In contrast to CAT-H, CAT-P instrument can execute “First Trip” test.Both instruments display numerical and graphical results. Because of that, a user can easily overlay up to 4 records in the graphical form and make a quick on-site analysis of potential defects.A user can download test results to a PC via Bluetooth interface for more detailed analysis using DV Win software.
-
product
Battery Capacity Testers|Discharge Testers
DV Power offers a wide range of battery capacity testers to meet specific customer needs. All of them are portable, powerful and most of all universal. Any battery string, such as lead-acid, lithium-ion, nickel-cadmium based and others, with voltages in the range of 0,9 – 800 V DC can be tested in an accurate, user-friendly way.The capacity test is carried out following the battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.BLU battery testers enable setting the discharge current up to 350 A, with 0,1 A resolution. If higher currents are required, several units can be connected in parallel, or BXL additional load units can be used. Discharge parameters can be monitored in real-time during the capacity test. Overall battery voltage, current, elapsed test time and capacity will be presented during the entire test on a touch screen display.
-
product
Turns Ratio Testers
TRT Advanced Series
TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.
-
product
Turns Ratio Testers
TRT Standard Series
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
product
Coil Analyzers & Power Supplies
Coil analyzers and power supply units are portable and lightweight devices intended for use in harsh switchyard and industrial environments. The typical application is switchgear and circuit breaker testing when substation battery is not connected or available. An advantage over substation battery is enabled testing in under-voltage and over-voltage conditions. Furthermore, the stable voltage outputs with a very low ripple (<0,5%) enable an analysis of the coil and motor current graphs recorded with circuit breaker analyzers from different vendors.SAT40AD, POB30AD, and POB40AD are unique devices in the market due to their dual purpose:Power supply for coils and spring-charging motorsTesting circuit breaker’s coils, motor, and auxiliary circuitAll DV Power coil analyzers and power supply units have four separate outputs for opening and closing coils.SAT40AD has two powerful motor outputs (AC and DC) which can withstand up to 40 A inrush current.POB30AD and POB40AD have DC motor output rated up to 30 A and 40 A respectively. With the use of motor outputs, POB and SAT can also be used as a power source or a temporary battery charger.SAT40A II series instruments can be controlled via PC. The DV-Win application software is used to control both SAT and CAT (Circuit Breaker Analyzers & Timers) devices at the same time, making a unique test system for switchgear and circuit breaker testing.
-
product
Tap Changer Analyzers & Winding Ohmmeters
Winding resistance test of inductive test objects, such as power transformers, is one of the most effective non-intrusive ways of checking its condition. Due to their advanced design, DV Power winding resistance meters provide high test currents (up to 100 A DC) and high accuracy (up to 0.1%) within light and portable test instruments. In addition to winding resistance measurement, it is also possible to perform simple, quick and reliable transformer on-load tap changer condition assessment by recording the test current during tap changer operation, also known as DVtest. Because of that, problems with a tap changer connection, contacts, and switching procedure can be detected.DV Power winding ohmmeters consist of single-phase RMO-T and three-phase TWA series. Models from the TWA series are designed for six-winding resistance measurement of power and distribution transformers, with only one single-step cable setup. As a result of reducing the total test time, it enables significant saving of time and money.Typical application areas of these instruments are high-voltage substations and industrial environments. They are intended to measure the resistance of:Transformer windingsOn-load tap changersGeneratorsElectrical motorsHigh-current bus bar jointsCable splicesWelding joints
-
product
Transformer Turns Ratio Testers
Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.
-
product
Battery Supervisors
DV Power manufactures ideal tools for maintenance, troubleshooting and performance tests on stationary batteries.Capacity testing is performed in order to detect which cells in the string should be replaced by measuring a cell voltage, temperature, inter-cell connection voltage, and specific gravity.IEEE standards for stationary battery applications also stipulate measuring these key parameters during periodic battery inspections.DV Power provides two types of instruments:BVS series – for automated monitoring of battery parametersBVR series – for manual monitoring of battery parametersIn contrast to BVS, BVR instruments can be used for the transfer of electrolyte specific gravity measurements from a density meter (DMA35) via Bluetooth. This provides a more extensive analysis of each cell in the tested battery string.
-
product
Micro-Ohmmeters
RMO-G Series
The RMO-G is a portable micro-ohmmeter designed for contact resistance measurement of non-inductive test objects and applications with increased safety requirement. It tests medium and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links. Due to its Both Sides Grounded and Remote Control functionalities, the instrument accurately measures even in the most demanding environments, providing additional safety to testing personnel.The RMO800G is the most powerful portable micro-ohmmeter on the market with 800 A output current. RMO200G is our best seller in the USA. A user can choose the appropriate model depending on the output current requirement, from 100 A (RMO100G) to 800 A (RMO800G).We use an unbreakable plastic case with IP67 protective rating (with closed lid) for instruments’ housing. Although very portable and lightweight, RMO-G micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents. Consequently, it enables the usage of thinner/longer test cables. RMO-G generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. During the testing, it increases current before measuring and decreases current after the measurement. This significantly decreases magnetic transients and ensures great accuracy.Special current clamps measure a current through groundings when the instrument tests in Both Sides Grounded conditions. The instrument itself powers these clamps. If even higher safety level is required, the Remote Control feature enables the operator to perform measurements from distant locations.RMO-G instruments can store up to 500 measurements in internal memory. Also, they have a built-in thermal printer and USB flash drive available as an option. An additional option is the built-in High Precision module suitable for measurement of very low resistance, in the range from 1 to 30 µΩ, with 0,01 µΩ resolution.Our free DV Win software communicates with the RMO-G micro-ohmmeters via USB or RS232 interface. It allows a user to run the test remotely from a PC. Also, a user can download test results, analyze and generate fully configurable test reports through the software.