Contaminant
-
Product
Food Monitoring Systems
-
Is a system of repeated examination, measurement and evaluation of levels of undesirable substances, such as plant protection products, heavy metals and other contaminants, in and on food.
-
Product
Soluble Salt Profiler
130 SSP
-
The Elcometer 130 Soluble Salt Profiler provides fast and accurate measurement of the level and density of soluble salts - over 4 times faster than other Bresle equivalent methods. The new Elcometer 130 Soluble Salt Profiler allows you to complete a Bresle equivalent test in just over two minutes. The multi-point conductivity sensors enable the Elcometer 130 SSP to accurately display salt concentration, showing exactly where the contamination lies and generating full colour salt density maps in 2D or 3D.
-
Product
Universal Differential pH Water Quality Sensors
SD7500CD
-
Continuous online pH monitoring in wastewater and coating industrial applications leads to contamination and eventually requires sensors to be replaced. A differential pH sensor utilizes a measurement technique designed to extend the working lifetime of sensors in challenging applications. Replacing the sensor reference (salt bridge) and buffered electrolyte solution can prevent sensor replacements, saving time and money. Our SD7500 Series features a combination sensor output; these differential pH sensors can be used with any conventional pH/ORP transmitter.
-
Product
Oil Tan Delta Test Set
-
The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. OTD test sets are supplied with sixteen standard test sequences pre-installed, to support a set of international standards.
-
Product
PXI 8 Channel Switch Simulation Module
40-480-021
-
The 40-480 is designed to simulate the operation of automotive switches where dirty contacts or leaking current can be expected from switch contamination. It allows automotive I/O devices to be tested for correct operation under adverse conditions.
-
Product
4-Wire Resistance Measurement | Continuity & HiPot Cable & Wire Harness Testers
-
An add-on option for the CableEye HVX high voltage cable tester series that permits expanded testing for contact and wire resistance as low as 1 mΩ. After checking for opens, shorts, miswires, and resistance limits, the 4-wire Kelvin measurement applies a user-selectable test current from 10 mA to 1 A to determine connection resistance within 1 mΩ. The resistance profile of a model cable may be stored and used as a basis of comparison during later testing to reveal cold solder joints, faulty crimps, recessed pins, pin contact contamination, improper wire gauge, and stress-extruded wire.This option may be purchased with any new HVX tester, or added as an upgrade to any of your existing HVX testers.
-
Product
Ionic Contamination Test System
Omegameter SMD 650
-
The SCS Omegameter SMD 650, the long-time industry standard for ionic testing utilizing “static test” methodology, is designed to perform cleanliness testing on printed circuits and assemblies. Identifies the presence of ionic contamination on bare and assembled printed circuit boards and other electronic components. Provides an accurate and repeatable method for determining cleanliness on site. Provides immediate process control results, eliminating the need for outside laboratory testing.
-
Product
Chromatography Columns - Alumina
RediSep Alumina
-
Single use alumina columns run under normal phase conditions and offer different selectivity to silica. Neutral alumina columns are useful when samples are acid sensitive and prone to degradation on normal phase silica gel.Choose basic alumina to purify basic compounds without basic modifiers such as TEA or ammonium hydroxide. This avoids solvent swapping, washing the chromatography system, or contaminating subsequent runs.
-
Product
PXI Dual 8 Channel Switch Simulator
40-485-121
Switch Module
Designed to simulate the operation of automotive switches where dirty contacts or leaking current can be expected from switch contamination. It allows automotive I/O devices to be tested for correct operation under adverse conditions.
-
Product
Material Discrimination X-ray Technology
MDX
-
Eagle’s Material Discrimination X-ray (MDX) technology enhances traditional x-ray inspection, providing food processors with unprecedented contaminant detection capabilities.
-
Product
Stealth Pipeline Metal Detector
-
Stealth Pipeline metal detectors are custom manufactured to suit any piped product application. The Stealth uses digital signal processing technology and has high sensitivity levels to ensure the detection of the smallest ferrous, non-ferrous and stainless steel contaminants. The built-in data collection software with USB data transfer establishes the Stealth as an effective critical control point complying with stringent HACCP regulations.
-
Product
Dial Indicators
-
1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.
-
Product
Chemical Testing
-
Accolade Engineering Solutions
To ensure product environmental compliance or to gain better understanding of your materials or processes, chemical testing is often required. AES has state of the art the equipment for chemical analysis. For elemental analysis XRF, SEM/EDS or ICP can be used. For molecular analysis GCMS, HPLC and FTIR may be used. FTIR may also be used for surface analysis of contamination and our microFTIR system is suitable for the smallest samples.
-
Product
Root Cause Failure Analysis
-
Maintenance Reliability Group, LLC
Root Cause Analysis of Grease Lubricated Components: Root cause analysis includes a complete root-cause failure report and recommendations for further monitoring and corrective actions. MRG will test for grease consistency, oxidation, product contamination and wear metals utilizing Grease Thief® Analyzer die extrusion test, FTIR, RULER and RDE Spectroscopy. Testing includes Analytical Ferrography and Rheometer testing. Testing can include the submission of a failed component for extraction of grease from failed component and visual inspection for Root Cause Analysis.Root Cause Analysis of Grease Lubricated Components: Root cause analysis includes a complete root-cause failure report and recommendations for further monitoring and corrective actions. MRG will test for grease consistency, oxidation, product contamination and wear metals utilizing Grease Thief® Analyzer die extrusion test, FTIR, RULER and RDE Spectroscopy. Testing includes Analytical Ferrography and Rheometer testing. Testing can include the submission of a failed component for extraction of grease from failed component and visual inspection for Root Cause Analysis.
-
Product
Fluid Contamination Test
-
Fluid contamination testing determines the abilities of materials to withstand the contaminating fluids, to which they are exposed in service.
-
Product
Contaminating Fluid Testing
-
Products manufactured using plastics, coated and painted surfaces, seals or other "A" surface materials can come in contact with spilled chemicals, sweat, cleaners, lubricants and fuels that can be a potential stress source for a product. These stress sources can cause discoloration, deterioration and de-lamination failures. We can create a list of fluids and/or follow TRCA, DO-160, MIL-STD-810 and ASTM guidelines for a list of products that should be used to test your part's compatibility.
-
Product
Stealth In-Foil Metal Detector
-
Stealth In-Foil metal detectors are custom manufactured to suit any foil packaging application or aluminum casting inspection. The Stealth uses digital signal processing technology and has high sensitivity levels to ensure the detection of the smallest ferrous contaminants, despite the presence of foil packaging. The built-in data collection software with USB data transfer establishes the Stealth as an effective critical control point complying with stringent HACCP regulations.
-
Product
Chloride/Sulfate Analyzer
Thornton 3000CS
-
The METTLER TOLEDO Thornton 3000CS Analyzer is an on-line instrument for direct measurement of chlorides and sulfates in pure water and power cycle chemistry samples. The analyzer continuously monitors these highly corrosive contaminants to assist in corrosion control and minimizing damage to critical power plant equipment. Early, unambiguous detection of trace levels of chloride and sulfate ions is provided with minimal operator supervision.
-
Product
Digital Dailysate Meter
Digital Dialysate Meter™ D4 & D6
-
The DIGITAL DIALYSATE METER is specifically designed to test both acetate and bicarbonate dialysate quality. Measure Conductivity, pH and Temperature to ensure proper mixing during dialysate preparation and as a final check of dialysate quality before hemodialysis treatment. There are no strips or reagents that expire or subjective interpretation of results. Internal sensors require the user to place the sample in the instrument, preventing contamination of dialysate by the measurement device.
-
Product
Solid State Relay Products
-
DARE Electronics? solid state relays incorporate advanced microelectronic hybrid technology and are available from low level to 50 amps. Solid state relays have distinct advantages over electro-mechanical devices including: no contact bounce, arcing or flashing; immunity to contact contamination and oxide formation in dry or normally open circuits; and immunity to shock and vibration thus preventing unwanted contact closures
-
Product
Laboratory Ferrography
T2FM 500
-
The SpectroT2FM 500 Analytical Ferrography Laboratory is a complete analytical system for the separation and interpretation of wear and contaminant particles in used lubricant oils, hydraulic fluids, coolants and fuels. It consists of the T2FM Ferrogram maker, a bichromatic microscope, video camera and image capture software.
-
Product
Humidity Sensors
-
digital humidity sensor with integrated temperature sensor that provides excellent measurement accuracy at very low power. The device measures humidity based on a novel capacitive sensor. The humidity and temperature sensors are factory calibrated. The innovative WLCSP (Wafer Level Chip Scale Package) simplifies board design with the use of an ultra-compact package. The sensing element of the HDC1008 is placed on the bottom part of the device, which makes the HDC1008 more robust against dirt, dust, and other environmental contaminants. The HDC1008 is functional within the full 40C to +125C temperature range.
-
Product
Dust Caps, Opens
-
These coaxial dust caps are used for protective purposes, both from the environment & contaminants. Note: SMA, 2.92, 3.5mm dust caps are the same, as the threads are the same. Likewise, 2.4mm & 1.85mm dust caps are the same, the threads being the same. Some people use opens for calibration purposes at low frequencies, but these opens are not VNA rated, we don't measure fringing capacitance etc.
-
Product
Ultrasonic Cleaners
-
Ultrasonic Cleaners are designed to remove grease, dust or other contaminants from surfaces and cavities of small objects, parts and samples such as cuvettes, lenses, glassware, medical and dental instruments, metals, guns, jewelry and more.
-
Product
Remote Plasma Sources
-
Semiconductor and Electronic Thin Film applications use plasma sources to generate low-energy ions and radicals to react with material surfaces and chamber walls to remove contaminants and act as a precursor to aid in material deposition. MKS provides multiple options for radical generation including Toroidal and Microwave based Remote Plasma Sources supporting Fluorine, NF3, oxygen, nitrogen and hydrogen process chemistries.
-
Product
PXI Dual 16 Channel Switch Simulator
40-485-321
Switch Module
Designed to simulate the operation of automotive switches where dirty contacts or leaking current can be expected from switch contamination. It allows automotive I/O devices to be tested for correct operation under adverse conditions.
-
Product
Pass-Through Oven
UF TS
-
The Memmert heating oven with fully insulated stainless steel door on both sides saves time during loading and reduces the risk of contamination, specially when handling sensitive load between grey and clean rooms. On this page, you can find all the essential technical data on our pass-through oven. Our customer relations team will be pleased to help if you want further information. If you should require a customised special solution, please contact our technical specialists at
-
Product
Sample Pretreatment For Optical Emission Spectrometry
-
Samples are taken from molten metal, thin sheet, semi-complete or complete products. When sampling molten metal with a ladle, small quantities of molten metal are poured into a casting mold. Unnecessary parts of the sample are removed using a grinder or a cutter. As particles from a grinder may contaminate the surface of the sample, a lathe or milling machine is used (not a grinder) to cut soft samples such as white metal. If trace elements are not being investigated, a grinder or belt sander can be used. However, to minimize contamination, the grinding wheel or belt should be changed for each sample. Samples excised from semi-complete or complete products must be at least 12 mm in diameter. Small rod-shaped samples can be analyzed using special equipment.
-
Product
Switch Mode Power Supplies-Air Cooled
-
The MS-Series features constant voltage and current control with easy, quick installation and maintenance. Modular versions easily increase the output by means of series or parallel connection. All models have DC short circuit protection. With forced air-cooled models, the cooling air quantity is controlled in relation to the load reducing contamination and noise levels.
-
Product
X5 Pipeline X-Ray Inspection
-
Designed to be integrated into the production line and available with product pipes in 2.5 and 3 ", the X5 pipeline is perfect for a wide range of pumped products such as poultry, meat, slurries and sauces. The system is capable of offering good detection levels on a wide range of contaminants including all metal, bone, glass, dense plastics.