Phasor Measurement Units
synced remote wave monitors measuring ac current and voltage on a power grid. Also known as: PMU
See Also: PMU, Smart Grid
-
product
Fiber Optic Crank Angle Measurement System
CP-5730/CP-0610/CA-6000B
CP / CA series are systems that detect the rotation angle of the engine crankshaft composed of CP-5730 Fiber Optic Crank Angle Detector, CA-6000B Crank Angle Amplifier and CP-0610 Rotation stop jig.
-
product
Temperature Measurement IR Sensors & Detectors
ST150 With Diffractive Lens
A single-channel silicon-based thermopile with integrated diffractive lens and internal baffle that delivers a very low Temperature Coefficient of Responsivity of -0.04%/C with a high output voltage, 19.5 FOV and a quick time constant of 38ms. This Low-cost detector comes in a TO-5 package and has a very short thermal shock response to ambient temperature change.
-
product
Insulation Resistance Measurement
MI20KVe
The MI-20KVe High-Voltage insulation tester is a truly portable device that allows the measurement of insulation resistances using test voltages up to 20 kV.
-
product
Clamp type AC Current Sensor/for Low Leakage Current Measurements(ZCT Series)
ZCT-18S
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Best sensor for low leakage current measurements of less than 1mA.*Ultra compact size with 18mmφ jaw opening capability.*High sensitivity and least affection from external magnetic field.
-
product
Basic Pulsed-RF Measurements For E5081A — Up To 20 GHz
S960250B
Add pulsed-RF measurement capabilities to your E5081A ENA-X vector network analyzer.
-
product
High-Precision Fuel Flow Measurement System
It enables to keep the temperature fluctuation of the circulation flow path in the system within ±0.2 °C (for 1 minute), which achieves stable fuel flow rate measurement.
-
product
Non-contact Measurement Wafer Sorting System (Belt Drive Tranceportation)
NC-6800
*Non-contact measurement of resistivity, thickness and conductivity (P/N)*Number of cassette station can be changed by customers request*Eddy current method for resistivity, Electric capacitance method for wafer thickness*Temperature correction for silicon wafer function
-
product
Antenna Tuning Unit
MS 2012
Antenna Tuning unit is used to automatically tune the notch antenna impedance. Microprocessor does tuning through tuning inbuilt algorithm. It has RS485 interface for external control unit interface. Capacitor unit (CU), Inductor unit, (IU) and RF Element are subunits of this antenna-tuning unit. System maximizes transmission.
-
product
Multi Output Buffer Unit
MS 1632
The Multi Output Buffer Unit is used for driving singe input to 32 outputs. This unit drives an analog input to two different 16 set of outputs through two 50 Pin standard D Type connector. The unit works on standard 230V AC.
-
product
Free Measurement System
CFMS
The Cryogen Free Measurement System (CFMS) from Cryogenic Ltd is a modular research system designed to enable the user to perform a wide range of material characterisation experiments in variable field and variable temperature environments.
-
product
SAR Measurements
SAR measurements, ie the measurement of the specific absorption rate, checks the amount of radiated high-frequency energy that a human body z. B. is exposed while using a mobile phone, laptop, data card. SAR measurements enable an assessment of the relative safety of radio devices with low power (low-power transmitters), which are used in close proximity to the human body.
-
product
FTIR Exhaust Gas Analyzer Direct Measurement Type
FTX-ONE-CS/RS
The FTX-ONE offers a 5Hz sampling rate and simultaneously measure the concentrations of multiple components including NH3, CH4, and CO2, from (engine) direct exhaust gas using the Fourier Transform Infrared (FTIR) method in combination with multivariate analysis algorithm.
-
product
Phase Noise Measurement Up To 70 GHz
S930317B
S930317B enables phase noise measurements using a PNA or PNA-X vector network analyzer. Simplify your measurement workflow by measuring phase noise on the same connection as your network analysis measurement of 2-port active devices up to 70 GHz, without needing to connect a spectrum analyzer or harmonic mixer.
-
product
Smart Inductive Digital Measurement Sensors (DMS)
Contrinex Smart Inductive Digital Measurement Sensors (DMS)
-
product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-600B Open loop method
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
product
Temperature Measurement System
6625T
Temperature Measurement System provides demanding users around the world with the best in temperature measurements and value. Incorporating unique features, this system is a true "turn-key" Temperature Measurement System. The 6625T System provides leading measurement specifications with uncertainties as low as 0.013 mK and the widest range of options available from any manufacturer.
-
product
Analog And Digital Sensor Measurement Data For CAN Applications.
K- AN8
The stackable K-AN8 is our cost effective solution to measuring analog and digital/PWM sensors together in one module. Extremely easy to use and stackable with all of our other K-series instrumentation modules. The K-AN8 includes our unique power down and WakeOnCAN feature for quick installation on long term unattended fleet test vehicles.
-
product
Temperature Measurement
K- TC16
The K-TC modules belong to the Influx K-series instrumentation range for CAN applications. The stackable K-TC is an ideal for those applications that require a large number of thermocouples for example vehicle durability, winter and summer testing.
-
product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-400B Open loop method
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
product
Glare Measurement System
GMS-1000
Hangzhou Hopoo Optoelectronics Technology Co., Ltd
Glare is one of the main factors affecting the health of the light environment. At present, there are many different models for glare evaluation, and different evaluation models are used according to the specific lighting application environment. According to the glare evaluation model, glare evaluation needs to be based on a number of key physical parameters. In actual field measurement and analysis, due to the influence of many factors such as the environment, there are higher requirements for the performance of measuring instruments.
-
product
Measurement Types and Kits
Keysight supplies a wide variety of optics for different calibration measurements. Choose individual optics or a pre-configured kit. Select desired measurement type from the chart or individual optics listed below.
-
product
Current Measurements of PWM or Inverter, AC/DC 1~50A, φ16mm
CTF-50DC
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 1~50A*Current measurements for PWM or inverter
-
product
ForceTest Force Measuring Software
AMETEK Sensors, Test & Calibration
The ForceTest software interfaces directly with your digital force gauge enabling you to automatically capture tests and graphs on a personal computer. Test results and graph can be monitored directly on the live screen in real time while the test is being performed.
-
product
Vector And Scalar Mixer / Converter Measurements
S95083B
The Keysight S95083B measurement software includes the scalar mixer / converter plus phase (SMC+Phase) measurement class. It provides fully calibrated conversion gain / loss, relative phase, and absolute group delay measurements of mixers and converters without the need for reference or calibration mixers. Eliminating the calibration mixer requires a U9391C / F / G comb generator and an external DC power supply. A vector mixer characterization (VMC) is also included for measuring group delay of frequency-converting devices. VMC can be used to characterize a user-supplied calibration mixer.
-
product
Flow Measurement Trainer Using Orifice Meter
Unitech Scales And Measurements Pvt. Ltd
This setup is a table top model, it comprises of source and measuring tank. The measuring tank is of acrylic with liters graduated. A small FHP pump is fitted to circulate the water. A orifice meter with U-tube manometer is provided to measure the flow rate. A rotameter is provided to measure the exact flow rate. Control valve is provided to control the water flow rate. Digital timer is provided to notedown the duration of flow.
-
product
Analytical Measurement
Dou Yee Enterprises (S) Pte Ltd
Dou Yee Enterprises Analytical Measurement Products including humidity temperature & airflow meter, autoanalysis system set, electrostatic field meter, static decay timer, and others.
-
product
Tactile Pressure and Force Measurement
I-Scan® System
This versatile tactile pressure measurement system is tailor-made by choosing from over 200 pressure sensors to meet your specific application requirements.
-
product
Buss Interface Unit Tester
BIUT 820
Quickly and reliably check any BIU with the BIUT-820 which provides comprehensive, fully automated testing in the field or at the shop.
-
product
Straightness Measurement Kit
55283A
The Keysight 55283A Straightness Measurement Kit, used with the Keysight 5530 Laser Calibration System, makes straightness, squareness and parallelism measurements to identify geometry errors that seriously degrade machine tool performance. These measurements allow documentation, analysis and diagnosis of machine tool travel and parallel axes of motion.
-
product
Total Organic Carbon Measurement
Total organic carbon (TOC) measurement is a well-established technique that provides valuable information about water quality for process control and regulatory compliance. Around the world, people have relied on our instrumentation for fast, accurate results for over 45 years. Our Total Organic Carbon (TOC) portfolio includes the 1080 Combustion TOC Analyzer, the 1030W Wet Oxidation TOC Analyzer, and the 1030D Dual Mode Analyzer – all of which are individually designed to help laboratories maximize efficiency.