-
Product
Exposure Level Tester
ELT-400
-
*Wide frequency range (1 Hz - 400 kHz)*Standard-compliant measurement*Acceptance measurements compliant with CE standard IEC/EN 62233 and Generic Standard IEC 62311*Limit value traces conforming to ICNIRP 1998, 2010 and EMF Directive 2013/35/EU*Real time measurement with RMS and peak detectors*External FFT signal analysis for determining the frequency components via three channel analog output (one channel for each spatial axis) e.g. with the aid of a digital oscilloscope.
-
Product
Short Test Pin Probe 13
CX-13
-
Shenzhen Chuangxin Instruments Co., Ltd.
Short Test Pin Probe 13 Used to test accessibility through enclosure openings per IEC, EN, UL and CSA Standards.
-
Product
Noise Dosemeters
-
Noise Dosemeters are a type of sound meter designed to measure the levels of noise exposure to an individual over a period of time. All of our dosemeters are compliant to IEC 61252: 1993 / BS EN 61262:1997 and offer high quality and reliable personal noise monitoring solutions.
-
Product
Body Temperature Monitoring System
TEMPMED
-
TEMPMED is a non-contact body temperature measurement system fully compliant with IEC 80601-2-59:2019 Standard
-
Product
Sound Level Meters
-
Acoustic Data These definitions are intended simply as an aid to understanding and for this reason, some are not strictly scientifically accurate. For correct formal definitions, consult IEC standards 60651, 60804, 60942, 61252 and IEC 61672: 2003 part 1.
-
Product
IP code Testing
-
Educated Design & Development, Inc.
Ingress Protection Test Equipment is used to determine the degree of protection provided by a product enclosure. The level of protection provided by an enclosure is represented by an "IP" code (i.e. IP43). The first digit indicates protection against ingress of solid foreign objects. Many of these tests require accessibility probes. The equipment for these tests is provided below. All equipment fully complies with IEC 60529 (IP Code standard) and all other international standards with similar tests.
-
Product
Annual testing of Automatic Identification System
AIS
-
The purpose of an annual testing is to determine that AIS is operational as defined in appropriate performance standards - the International Maritime Organization (IMO) Performance Standard (MSC 74(69)) and IEC standard, IEC 61993-2: Maritime Navigation and Radio Communications Equipment and Standards Automatic Identification Systems (AIS).
-
Product
Sound Meter
4431
-
The Kanomax Sound Meter – Model 4431-1G is the world’s first 0-dB function sound meter available. It is designed to meet Type 2 standards for ANSI S1.4 1983 and IEC 61672-1. The magnetic accelerometer easily attaches to machinery for increased accuracy and precise operation.
-
Product
8GE+2G Combo Managed Ethernet Switch
EKI-7710G-2C
-
Certified to IEC 62443-4-2 SL2, 8 Gigabit ports + 2 Gigabit Copper/SFP combo ports, Redundancy: Gigabit X-Ring Pro (ultra high-speed recovery time < 20 ms), RSTP/STP (802.1w/1D), IXM function enables fast deployment.
-
Product
Salt Spray Test Machine
YWX/Q-010
-
The Salt Spray Test Machine/Chamber is applicable to the salt spray corrosive test for the protection layer of components, parts, electronic and electrical parts and metal materials and industrial products. • The Salt Spray Test Machine is made of transparent materials so that the operator can see the tested sample in it and the spraying situation of the tested sample. • A waterproof structure is adopted between the chamber cover and chamber body, thus there is no salt spray overflow. • Adopts the tower spraying system and equipped with the salt solution filter system and non-crystal nozzle so as to realize even salt spray distribution and freely adjustable settlement. • It meets the following standards: IEC60068-2-11 (GB/T2423.17), GB/T10125, ISO9227, ASTM-B117, GB/T2423-18, IEC 60068-2-52, ASTM-B368, MIL-STD-202, EIA-364-26, ASTM-B117, GJB150, DIN50021-75, ISO3768, 3769, 3770; CNS 3627, 3885, 4159, 7669 etc.
-
Product
K Thermocouple Penetration Probe
TP776
-
“K” Type thermocouple penetration probe. Tolerance according to IEC 60584-2 standard.
-
Product
IEC60335 Nail Test Probe
CX-Z12
-
Shenzhen Chuangxin Instruments Co., Ltd.
The Finger Nail Probe is indicated to test IEC 60335 and UL requirements. Used to check the security of parts that snap together. The spring gauge assembled in the handle can be calibrated to the necessary force for using the instrument. This probe is made of stainless steel with appropriated hardened tip and a handle in insulating material. Handle has a special adaptor M5 for use with 50N force gauges.
-
Product
Datalogging Digital Sound Level Meter with RS-232 Software and Cable
735
-
Whether you are testing for OSHA compliance, quieting equipment, or monitoring the roar of a stadium crowd, B&K Precision's Sound Level Meters can get the job done. The model 735 Sound Level Meter provides 30~130 dB capability in three convenient measurement ranges Low, Med and Hi with an accuracy of ±1.5 dB. The meter meets the IEC 651 Type II and includes frequency weighting A & C and fast and slow time weighting.
-
Product
Fanless Embedded System With 7th Gen Intel® Core™ I7/i5/i3 & Celeron® Processor For Railway And Marine PC
tBOX300-510-FL
-
*CE, LVD, FCC and EN 50155 certified; EN 45545-2 and IEC 60945 compliant*7th gen Intel® Core™ i7/i5/i3 & Celeron® processors (Kaby Lake)*Fanless and wide operating temperatures from -25°C to +70°C*Power Input:**24 to 110 VDC for railway version**24 VDC for marine version*External PoE PSU (optional), up to 60W power supply*Value-added modules available for various I/O requirements (COM/LAN/DIO/PoE/CAN/BNC)*4 swappable 2.5" SATA drives, Supports Marvell Hardware RAID 0/1/10
-
Product
4G Router
ICR-2734-S1
-
ICR-2700-S1, EMEA, IEC 62443-4-2, 2× ETH, USB, Metal, No ACC LTE Cat.4 with 3G/2G fallback Security based on IEC 62443-4-2 level 1. 1.3 GB eMMC storage to host customer SW applications 2× SIM with cover, eSIM ready.
-
Product
Qualification and Quality Control Tests
Techsquare
-
New IEC standards, IEC 60034-18-41 and IEC 60034-18-42, have been issued to define the procedures for testing partial discharge inception voltage and the long-term performance (endurance) of Type I and Type II insulation systems used in rotating machines fed from voltage converters. Voltage impulse generators are required at least to test turn insulation, but they would be recommended for any testing under power electronics supply because of their capability to simulate the real electrical stress conditions. More generally, any type of electrical insulation system when subject to impulsive voltage waveform during life should be carefully evaluated in terms of partial discharge and endurance behaviour. This is why voltage impulse generators able to provide impulses with controlled amplitude and frequency are needed to face this new testing challenge.
-
Product
Hipot Testers
V7X Series
-
With color touch LCD & high speed DSP technology, the compact & rugged V7X sets the standard for price/performance ratio. Made in the USA to meet tough UL, CSA, TUV and IEC Hipot requirements – the V7X provides unbeatable speed, accuracy, user safety and reliability.
-
Product
Common Meter Reading Instrument - CMRI 1010
CMRI 1010
-
Signals & Systems India Private Limited
Common Meter Reading Instrument (CMRI) is a handheld computer used to download data from electronic tri-vector meters, supporting different protocols like IEC, ANSI and PACT. CMRI is also compliant to IS-15959/ DLMS (IEC-62056) standard. CMRI can be interfaced with the portable printer for spot billing applications.SANDS CMRI-1010 comes with LCD Graphical (3.5” TFT) & 15Line x 40 Characters visibility is rugged to withstand drop on to concrete and waterproof. CMRI is available with a memory size of 512 MB.
-
Product
Surge Generator
SG61000-5
-
Automatic lightning surge generator (or Lightning surge immunity) SG61000-5 is used to assess the power cord and connect the internal switch stood in line to connect the internal switch to provide a common basis for switching the natural world and lightning caused by the high-energy transient interference performance. Performance fully meets the IEC 61000-4-5, EN61000-4-5 and GB/T17626.5 standards.
-
Product
Circuit Breaker Analyzers & Timers
-
CAT circuit breaker analyzers and timers are advanced standalone or a PC controlled instruments for circuit breaker maintenance. Typical application areas of CAT instruments are medium and high voltage substations at electric power generation, transmission, and factories of switchgear. Also, industrial environments and electric power distribution are suitable application areas for these circuit breaker testing instruments.DV Power CAT circuit breaker testing instruments are portable and lightweight. They are designed for performing mechanical operations intended for circuit breakers testing according to standards IEC 62271-100 and IEEE C37.09.These instruments measure:the timing of main contacts, pre-insertion resistor contacts, auxiliary contacts operations,coil currents,motion parameters,voltage recording,main circuit resistance,arcing contacts wipe,and any relevant analog signal.Motion transducer channels provide measuring a displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time, and average velocity. Even more, CAT circuit breaker analyzer optionally has a built-in micro-ohmmeter. Hence, it provides the main circuit resistance measurement and dynamic resistance measurement. Dynamic resistance measurement is an effective method for arcing contacts condition assessment.
-
Product
GNG-* “Go” and “Not go”gauge
GNG-*
-
According to the requirement of IEC 60061, Lisun produced high accuracy and high quality “Go” and “Not go” gauge • GNG-E27 is for E27 lamp cap standard source measurement. It includes 7006-27B-1, 7006-28A-1, 7006-27C-1, 7006-50-1, 7006-51A-2, 7006-51-2 • GNG-E27H is for E27 lamp holder standard source measurement. It includes 7006-25A-2, 7006-26-4, 7006-21-5, 7006-22A-4, 7006-22B-1, 7006-22C-1, 7006-22D-1 • GNG-E14 is for E14 lamp cap standard source measurement: 7006-27F-1, 7006-54-2, 7006-27G-1, 7006-55-2 • GNG-E40 is for E40 lamp cap standard source measurement: 7006-27-7, 7006-28D-1, 7006-52-1, 7006-53-1 • GNG-B22D is for B22d lamp cap standard source measurement: 7006-12-8, 7006-15-7, 7006-20-4, 7006-12A-2, 7006-12B-2, 7006-15A-2, 7006-13-5, 7006-17B-1 • GNG-B22DH is for B22d lamp holder standard source measurement: 7006-12A-2, 7006-12B-2, 7006-15A-2, 7005-10-8
-
Product
IO-Link Transceivers
-
IO-Link is a Factory Automation fieldbus-independent communication standard dedicated to connecting sensors and actuators as described in the IEC 61131-9 standard. Easily integrated with any of the most commonly used communication protocols found in factory automation systems through dedicated interfaces or bridges, it is a simple solution for extending existing networks to connect remote sensors and actuators. Developers will take full advantage of the Industry 4.0 or Industrial Internet of Things (IIoT) concept where every sensor and associated data point is used to control and optimize even the most complex industrial processes in real time.
-
Product
Single Sheet Tester (500 x 500) mm
-
Single Sheet Tester (500 x 500) mm is designed to measure dynamic magnetic properties of the electrical sheet according to IEC 60404-3 Standard. Single Sheet Tester (500 x 500) mm could be cooperating with following equipment designed to measuring soft magnetic properties:
-
Product
RCD/LOOP/PAT Testers
-
Kyoritsu Electrical Instruments Works, Ltd.
Custom microprocessor controlled for highest accuracy and reliability. 3 LEDs for checking correct wiring status. 0 and 180 degree phase angle switch permits quick tests and consistent readings. Digital read-out of tripping time. Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings. Large custom digital display readout. Visual indication of reversed phase and neutral wiring at socket. Designed to IP54 Rating. Complies with IEC 61557 Test of a large kind of RCD''''s: Standard, Selective, AC and A (DC sensitive breakers)
-
Product
2-Port SFP Ethernet Card
ECU-P1524PE
-
2-port SFP Ethernet cards supporting HSR/PRP (IEC 62439-3) are specialized NICs designed for zero-delay, high-availability industrial networks. These cards feature dual SFP ports to operate as Dual Attached Nodes (DAN) in HSR ring topologies or parallel PRP networks.
-
Product
1U Type Power Supply; ATX 300 W
PS300-1U
-
*Input Range: 90 ~ 264Vac Full Range8Output Voltage:**+5V, 14A**+3.3V, 12A**+12V, 25A (0.1A min)**-12V, 0.3A**+5Vsb, 3A*MTBF(hours): At 25°C, 100,000h*Safety: TUV, CSA22.2 NO.60950-1, IEC, UL, CE*Dimensions: 150 x 81.5 x 40.5 mm*Compatible with Axiomtek products: AX61120TB/AX61131TM/AX61133TM
-
Product
8GE+4SFP+4G Combo Port Managed Redundant Industrial Switch
EKI-7716G-4F4CI
-
Certified to IEC 62443-4-2 SL2, 12 ~ 48 VDC power input and 1 relay output, -40 ~ 75°C wide-range operating temperature (EKI-7716G-4F4CI). EN50121-4 approval for railway trackside deployment, NEMA TS2 for traffic control, Management: SNMP v1/v2c/v3, WEB, Telnet, Standard MIB, Private MIB.
-
Product
UL94 Horizontal & Vertical Flammability Tester
-
TESTEX Testing Equipment Systems Ltd.
UL94 Horizontal & Vertical Flammability Tester, used to determine the flammability of plastic materials for parts in devices and appliances. UL94 Horizontal & Vertical Flammability Tester complies with UL HB, UL94, IEC 60695-11-10, etc. Contact us for UL 94 flammability test procedure.
-
Product
110kV/220kV Substation Series Testers
JYH-C
-
The JYH-C CT & PT Analyzer is a multifunctional device for testing current and potential transformers, covering excitation, ratio, polarity, resistance, and more. It meets IEC standards and features L
-
Product
Walking Test System Kit
PGA-710
-
The PGA-710 Walking Test System is a complete kit designed to perform the walking test per ANSI/ESD STM97.2 and IEC 61340-4-5. The system consist of several devices designed for portability and to perform several different tests which includes measuring the voltage on a person in combination with floor materials and footwear.The kit includes the PGA-710B Data Logger, the PFM-711B Field Meter, CPM-720B Charge Plate Monitor, the PCS-730B Electrostatic Charger, Hand Held Electrode and the Prostat Autoanalysis Software version 2.0.





























