Standard Transformers
-
Product
Three-Phase Transformer Demagnetizer
DEM60C
-
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
Product
Power Transformer Monitoring
-
Optimize the efficiency of your transformers by relying on our flagship DGA monitoring system with long-term stability, no maintenance needs, no false alarms and a revolutionary method for detecting ambient air ingress.
-
Product
Incremental Transformer Solutions
TRANSPORT X
-
The Kelman TRANSPORT X is a compact portable Dissolved Gas Analysis (DGA) system which can be used to analyze oil samples for all dissolved fault gases and moisture. If abnormal levels are detected, it further provides a diagnostic using various IEEE/IEC approved interpretation rules.
-
Product
Precision Multirange Current Transformer
P-2000
-
The Type P-2000-2 Knopp Precision Current Transformer is useful for high and low voltage work in the laboratory, shop and field for testing, measuring, and calibrating. The excellent accuracy and the One-to-One calibrating feature make it admirably suited as a standard for calibrating work.
-
Product
Current Transformer Tester
CT-T1
-
The CT-T1 is a microprocessor-based Current Transformer Tester that measures CT excitation current, turns ratio, and winding polarity tests, all without having to switch the leads during testing. The instrument has a fully automatic knee point detection (ASA 10/50, IEEE 30°, IEEE 45°). Although includes 5 low side taps and 1 high side tap.
-
Product
Standard Gain Horns
-
Standard gain horns can be used to experimentally determine the gain of other antennas by using the substitution method. The standard gain horn and the antenna under test are alternately connected to a well matched detector system in order to compare their relative power levels. The power level difference is then added to the appropriate level of the calibration curve to determine the absolute gain of the antenna under test.View more Standard Gain Horn Antennas
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
-
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Standard RF Power Sensors
-
Coaxial Dynamics "Standard" line of RF Power Sensors provide DC currents proportional to the forward and reflected power flowing through the line. All models are designed to drive a 30A, 1400-Ohm meter, or provide approximately 100 millivolts across a 5K load.
-
Product
Hydrogen Frequency & Time Standard
CH1-1035
-
Hydrogen frequency and time standard Ch1-1035 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes.
-
Product
Transformer Protection
-
Schweitzer Engineering Laboratories, Inc.
Transformer protection products and systems provide complete primary and backup protection for all types of transformer faults. They are suited for use in utility-, industrial-, and commercial-scale power transformer systems.
-
Product
Calibration Standards
-
The accuracy of any spectroradiometric measurement can only be as good as that of the standard source used to calibrate the system.
-
Product
Standard Panel & Display Products
-
Standard Panel & Display Products by Teledyne Defense & Electronics
-
Product
Dynamic Primary Transfer Standard
RD-22
-
The RD-22 Dytronic Primary Transfer Standard represents the state-of-the-art technology in a commercially available true DC to AC accuracy transfer reference. The RD-22 has typical AC measurement accuracies within the limits of traceability. Repeatability of 1 ppm can be attained at 120 V and 5 A inputs of specific models.
-
Product
Instrument Transformer Calibrators
MRL 22
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Automatic measure of contact resistance. True 4 terminal measurement. μP operated, automatically saves results.
-
Product
Distribution Transformer Tester
NDB-DOC™
-
The NDB-DOC™ is a test instrument designed for distribution networks transformers from 10kVA to 2500kVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The NDB-DOC™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.
-
Product
Rubidium Frequency Standard
RFS VXI
-
*RFS VXI is designed to work as part of information measuring systems based on the VXI bus as a rubidium frequency standard.*RFS VXI is intended for use as a highly stable laboratory signal source for checking generator devices, time-frequency measuring equipment and other equipment, synchronizing navigation systems.*The RFS VXI contains two independent rubidium reference oscillators: main and standby.*RFS VXI is a VXI standard, register based device and measures C-1.*RFS VXI implements the "Self-control" mode, which checks the output frequencies of the rubidium standard.
-
Product
Instrument Transformer & Switchgear Testing
-
Our stationary and mobile instrument transformer test systems are used to test current and voltage instrument transformers. Among other things, accuracy testing, demagnetization and insulation testing are possible.
-
Product
Standard Precision GNSS Module
AIW-213
-
Half size mini-PCIe form factorStandard Precision GNSS L1 band92 Channels u-blox NEO-M9 engine (GPS, GLONASS, BeiDou, Galileo, QZSS and SBAS)USB 2.0 communication interfaceSupport Dead Reckoning (DR), Including IMU and Oscillator2 second TTFF for Hot Starts, Open sky code start 24 second.Accuracy 1.5M CEPOperating temperature: -40°C ~ +85°C / -40°F ~ 185°F
-
Product
15T Standard Running Line Monitor
RLM15T-3.0-S
-
The DLM 15T Running Line Monitor measures the tension on a rope passing through its three wheels. Typically used in cable laying and winch operations to measure and record line tension the robust design has become an industry standard. The monitor can be supplied as a separate item for integration with customers existing PLC’s or with a DLM digital display/HMI touch screen display.
-
Product
Standard Gain Horn Antennas
-
Linear polarized Broadband Horn Antenna (Brass with Plastic mounting body) for Receive and Transmit Applications.
-
Product
Transformer Monitoring
-
MTE offers a broad range of products and solutions for the online gas-in-oil monitoring of transformers (online DGA). With its individual and modular system components MTE provides the optimal customer oriented solution for utilities, industries and transformer manufacturers.
-
Product
PAL Standard Pattern Generator
PG315P
-
The MicroImage PG315 pattern generator is designed for simple size and geometry reference applications. The PG315 will overlay one of five standard patterns including a centered cross line, a centered cross hair, a centered target style symbol, a dot grid (cross dot) array, a hatch grid (crosshatch) array.
-
Product
CANbus Controller Standard Interface
PCI360
-
The PCI360 CANbus controller PCI card is based on the SJA1000. The SJA1000 provides an interface to the popular CANbus that support both standard (11-bit) and extended (29-bit) identifier messages. LEDs provide diagnostics information.The CAN network is a serial communication protocol which efficiency supports distributed real-time control with a high level of reliability.
-
Product
Electrical Standards
-
To verify the performance of an electrical calibrator or dc calibrator, you need an electrical standard. Fluke Calibration standards are found in primary calibration laboratories across the world. A wide range of electrical standards and frequency standards are designed to meet the needs of today’s laboratories for traceability and quality accreditation while also being portable, simple to use, and easy to support. Electrical standards include: Voltage standards; ac/dc transfer standards; ac measurement standards; resistance standards; ratio standards; current shunts.
-
Product
Standard Digital Multimeter - Auto Ranging
MM39
-
The MM39 is an auto-ranging multimeter with a large rotary switch for easy selection of the required test, even when wearing gloves. There are two test buttons, one to lock the range and the other to hold the results which are displayed on a 3½ digit LCD screen.
The main test functions are AC voltage and DC voltage and current and resistance. The MM39 measures both AC and DC voltage between 0.1mV to 600V and AC and DC current between 10mA to 10A. There is a diode test and an audible continuity test which sounds at less than 25Ω.
-
Product
High Impedance Transformers
-
Osborne high impedance transformers are used to step-up, step-down and isolate voltages in single phase and three phase circuits. A properly designed high impedance transformer can be used an an equivalent to an isolation transformer connected in series with an inductor. The high impedance characteristic may be employed as a current limiting feature in both the primary and secondary circuity.
-
Product
Calibration Standards, Calibration Services
-
ISO 17015 traceable calibrated reference lamps, detectors and reflectors for the calibration and adjustment of sensors and measurement devices for light, optical radiation and light reflection. We offer as well many ISO 17025 calibration services.
-
Product
Automatic Voltage Regulating Relay- Standard Model
-
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
Product
High Voltage Transformer
-
RR manufactures HIGH VOLTAGE TRANSFORMERS for various Industrial Applications.