Standard Transformers
-
Product
Testing of Current Measuring Transformers
-
All components from this category can be integrated into an existing current transformer test system. When selecting CT test components, both the type of converter to be tested and the required current are important.
-
Product
Capacitance Standard Set, 0.01uF To 10uF
16380C
-
The 16380C is a standard capacitor set consisting of three precision capacitors - 0.01uF (16385A), 0.1uF (16386A), 1uF (16387A),and an optional 10uF (16388A). These capacitors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
-
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Standard Attitude Gyroscopes
5000B-series
-
The 5000B is an air-driven gyro that has a pictorial horizon mask and fixed airplane. The mask moves to indicate climb, dive, and bank. Bank and pitch attitudes are displayed so that the pilot’s sensing of the gyro indication is the same as the interpretation of the relation between the wings of the aircraft and the natural horizon during visual flight.
-
Product
Standard Test Finger
SMT-1
-
It with Protection against electric shock device. It according to IEC60335, IEC60884, IEC61032, IEC60529, IEC60065, IEC60035, IEC60950, EN60529, EN60950, GB4706, GB7000, GB9706, UL507, VDE0470, etc.
-
Product
Transformer Testing Equipment
-
Offering you a complete choice of products which include Automatic Transformer Turns Ratio Instruments (ATRI- 3), Automatic Transformer Turns Ratio Instrument (ATRI-201), VTRI-2000 ( Transformer turns ratio instrument ), Current Transformer Test Set (CTC-1), Potential Transformer Tester ( PT Tester ) and Current Transformer Tester ( CT Tester ).
-
Product
Portable Three Phase Transformer
-
Supreme Instrument Laboratories
Portable 3 phase double wound transformers both step-up & step-down, natural air cooled construction, housed in well ventilated sheet steel cabinet duly powder coated. All the input and output terminals are brought out and terminated on highly insulated bakelite panels duly marked for easy connection. Necessary carrying handles and castor wheel will be provided for portability.
-
Product
Standard Method Compliant
-
Shimadzu System GC Analyzers are built and tested to meet the specific analysis requirements of applicable industry standards.
-
Product
Rubidium Frequency Standard
RFS VXI
-
*RFS VXI is designed to work as part of information measuring systems based on the VXI bus as a rubidium frequency standard.*RFS VXI is intended for use as a highly stable laboratory signal source for checking generator devices, time-frequency measuring equipment and other equipment, synchronizing navigation systems.*The RFS VXI contains two independent rubidium reference oscillators: main and standby.*RFS VXI is a VXI standard, register based device and measures C-1.*RFS VXI implements the "Self-control" mode, which checks the output frequencies of the rubidium standard.
-
Product
Standard Gain Horns
-
26 dB typical gain at center frequency. Aluminium made High performance Standard Gain Horn. From 75 GHz up to 500 GHzUG-387 U/M flange. Specific gain values can be requested. We offer two Standard Gain Horn product lines that go from 75 GHz up to 500 GHz, one with high performances for the most demanding of lab applications and the other with reduced prices and sufficient quality for the majority of SGH applications. Anteral makes sure that each client can have the best SGH for their particular needs.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF1200
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralizedcompensation of power factor in low voltage instalations
-
Product
Auxiliary Current Transformers
-
Osborne Auxiliary Current Transformers are often used to reduce system currents to lower values appropriate for instrumentation and/or protection circuits. The Aux CT’s are designed for specific current ratios and burden impedance with a known transformation error. Osborne’s units are built for high performance and longevity in the most demanding environments.
-
Product
High Frequency Current Transformer
HFCT Ø 140mm
-
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
Product
Multiple Gas Transformer DGA
TAPTRANS
-
The TAPTRANS is an 8-gas on-line transformer DGA monitoring unit designed to monitor the transformer and OLTC (On-Load Tap-Changer). The TAPTRANS can individually measure the Main, Selector and Divertor tanks in one unit. The photo-acoustic detection system used by the TAPTRANS allows measurement of high and low gas levels without the need for extensive recalibration/cleaning.
-
Product
Rubidium/GPS Frequency Standard
PXIe-3352
-
The Astronics Test Systems PXIe-3352 frequency standard module sets a new standard for high density functionality in a PXI module by combining a Rubidium oscillator with a GPS receiver into a single, compact instrument.
-
Product
Windows Embedded Standard
-
Componentized operating system lets you create a custom operating system image to deliver the necessary functionality for the device. Provide device users with a unique and powerful branded experience.
-
Product
Standard Brinell Hardness Tester
BRIN400 Series
-
The Standard Brinell Hardness Tester - BRIN400 Series of closed loop Brinell hardness testers represent the latest in Brinell hardness testing technology. They are robust, reliable, proven and designed to meet a customer’s most demanding requirements in harsh industrial environments such as those found in foundries, forges and steelworks.
-
Product
IEC Potential Transformer Burdens
-
• Burdens for IEC specifications rated for various input voltages available • 2.5 to 207.5 VA at 0.8 PFIEC Potential Transformer Burdens
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF1000
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralizedcompensation of power factor in low voltage instalations.
-
Product
Open Standard Module (OSM)
ROM-2620
-
Advantech ROM-2620 OSM 1.1 Computer-on-Module is powered by NXP i.MX 8ULP SoC which includes up to 2 Arm Cortex-A35 cores in combination with one Cortex-M33 real timeprocessor and Vivante GC7000 nanoULTRA/GC328 graphics engine. It provides USB2.0, Fast Ethernet, MIPI-CSI, I2C, SPI, GPIO, PWM and MIPI DSI display for embedded applications
-
Product
Transformer Ratiometer
TR-1C
-
Model TR-1C Transformer Ratiometer is a precision test set with an easy-to-read in-line digital readout from 0.00001 to 1.00000, suitable for testing all types of single and three-phase power distribution, potential and current transformers.
-
Product
Instrument Transformer Calibrators
CTPT 81
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
Product
Distribution Transformer Tester
NDB-DOC™
-
The NDB-DOC™ is a test instrument designed for distribution networks transformers from 10kVA to 2500kVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The NDB-DOC™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.
-
Product
Auto Transformers
-
Osborne often recommends Auto Transformers in situations where reducing physical size of the transformer is advantageous. Auto transformers offer size advantages when compared to equivalent isolation transformers. Auto transformers provide lower levels of regulation than the equivalent isolation transformer. Osborne helps our clients accommodate for the loss of regulation while achieving the physical size (and cost) advantages of auto transformers.
-
Product
ATTR Auto Transformer Turns Ratio Tester
-
Chongqing Assen Power Equipment Co., Ltd
Transformer turns ratio tester is a new type of fully automatic tester that uses modern electronic technology to measure the ratio of single-phase and three-phase transformers, and does not require any manual “zero” balance.
-
Product
Separating Transformers
-
Is a transformer in which the primary and secondary windings are galvanically/electri- cally separated with basic insulation. Isolating transformer: A separating transformer with a protective partition between the primary and secondary windings.
-
Product
Step Up Transformer
MagD
-
SCOPE proudly introduces Step-Up Transformer - MagD, specially designed to cater the needs of testing of instrument Transformers. Before new systems are put into service or after any occurrence of fault, the instrument transformers need to be tested for their outputs. It is to be ensured that these instrument transformers are giving proper outputs to the protective relays. MagD is used to plot excitation curves for instrument transformers. Inbuilt voltmeter and ammeter, eliminates the need of external meters for plotting of curves. It can also be used for de-magnetization of transformer cores and also turns-ratio tests can be conducted using MagD.
-
Product
Loss Measuring System for Transformers
LiMOS
-
HIGHVOLT Prüftechnik Dresden GmbH
The transformer loss measuring system LiMOS is designed for highly accurate measurement of losses and other parameters required in the framework of routine and type testing of power transformers. The combined voltage/current sensors and the digital signal processing enable a very compact design with only one HV device per phase with smallest volume and footprint. The digitized and preprocessed signals are transmitted via fiber optic cable to the receiver unit (LiMO-MCSU).