Remote Terminal Unit
Collects data from data acquisition (DAQ) devices and transmits the information to the main test system via a network.
-
Product
Precision Source / Measure Unit, 1 CH, 1 PA Resolution, 21 V, 1.5 A
B2901BL
Source Measure Unit
The Keysight B2901BL precision source / measure unit (SMU) is a 1-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
PXI 16-Channel 4-Bus 2A Fault Insertion Switch
40-197A-002
Fault Insertion Unit
This 16-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers.
-
Product
Single Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-101
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
USB Modular Source Measure Unit
U2722A
Source Measure Unit
The U2722A USB Modular Source Measure Unit is a 3-channel 20V/120mA that can operate in a 4-quadrant operation. The channels could be connected in series or in parallel to achieve up to 60 V/360 mA. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity allowing users to set up and configure their tests swiftly with its plug and play feature.
-
Product
SCB-100A Noise Rejecting, Shielded I/O Connector Block
785024-01
Terminal Block
100-Pin Female SCSI to 100-Pin Female Screw Terminal, DIN Rail, Wall, Pane Terminal. Block The SCB-100A is a shielded I/O connector block for interfacing I/O signals to NI data acquisition devices with 100-pin connectors. Combined with shielded cables, the SCB-100A provides rugged and protected signal connectivity. It has a mechanical enclosure that features a magnetic removable lid and pinout diagrams. It also includes pane, wall, and DIN Rail mount options.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
Fault Insertion Unit
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-193A-001-HI
Fault Insertion Unit
The 40-193A-001-HI is a 7-Channel Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
Product
SH96F-96M-5, Shielded Cable for PXIe-4330 and PXIe-4331 to Rackmount Terminal Block, 1 Meter
786341-01
Terminal Block
Shielded Cable for PXIe-4330 and PXIe-4331 to Rackmount Terminal Block, 1 Meter
-
Product
Precision Source/Measure Unit, 1 Ch, 10 FA Resolution, 210 V, 1.5 A
B2910BL
Source Measure Unit
The Keysight B2910BL Precision Source / Measure Unit (SMU) is a 1-channel, compact and cost-effective bench-top SMU with the capability to source and measure both voltage and current. It is versatile to perform I/V (current vs. voltage) measurement easily with high accuracy. Integration of 4 quadrant source and measurement capabilities enables I/V measurement simply and easily without configuring multiple instruments.
-
Product
PXI Fault Insertion Switch, 6-Channel, Two Fault Buses, 30 A, Hardware Interlock
40-191B-012-HI
Fault Insertion Unit
The 40-191B-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
Product
EBIRST 8-pin Male Power D-type Termination Fixture
93-012-103
Termination Fixture
eBIRST is a range of USB controlled test tools capable of performing automated path resistance tests on Pickering Interfaces PXI, LXI or PCI controlled switching solutions. Each tool simply interfaces with the switching system's connector so a test can be run using the supplied Windows-based software.
-
Product
BNC-2110, 68-Pin SCSI to Female BNC and Spring Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block
777643-01
Terminal Block
68-Pin SCSI to Female BNC and Spring Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block - The BNC-2110 can be used with various NI multifunction I/O and analog output devices. The BNC-2110 simplifies the connection of analog signals, some digital signals, and two … user-defined connections to the data acquisition device while maintaining the integrity of your measurements with a shielded enclosure. It includes a DIN Rail and a desktop mount option.
-
Product
Coaxial Termination, DC to 18 GHz
909A
Terminator
The Keysight 909A is a general-purpose, low-reflection load for terminating a 50-ohm coaxial system in its characteristic impedance over the dc to 18 GHz range. It is suitable for both broadband and narrowband measuring instruments. The Keysight 909A may be ordered with an APC-7, type-N female, or type-N male connector.
-
Product
PXIe-4139 , ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit
782856-03
Source Measure Unit
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel
50-201-008
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
Source Measure Unit
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
Product
PXI 5A Fault Insertion Switch 5-Channel
40-196-101
Fault Insertion Unit
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
PCI-8361, PCI Host, 100 MB/s, Copper Cable MXI-Express Device for PXI Remote Control
781394-01
Remote Control Interface
The PCI‑8361 is an MXI‑Express remote controller for devices or systems over cabled PCI from a computer with a PCI slot. The PCI‑8361 card provides a PCI link over a copper cable to the PXI‑8360 remote control module when used for PXI system control. This link is transparent to software applications and drivers, so computers and servers can control connected devices with no additional programming. With NI remote controllers, PXI modules can be used as if they are PCI devices directly installed in the computer.
-
Product
PXI/PXIe Fault Insertion Switch, 74-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-012
Fault Insertion Unit
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
Fault Insertion Unit
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
Product
3U OpenVPX Sensor Interface Unit
SIU34
Sensor Interface Unit
The SIU34 is a highly configurable rugged system or subsystem ideally suited to support a multitude of Mil-Aero applications that require high-density I/O, communications, Ethernet switching and processing. The SIU34 leverages NAI’s 3U OpenVPX™ boards to deliver off-the-shelf solutions that accelerate deployment of SWaP-optimized systems in air, land and sea applications.
-
Product
Precision Source / Measure Unit (2 Ch, 100 FA)
B2902B
Source Measure Unit
The Keysight B2902B precision source / measure unit (SMU) is a 2-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
Terminal Block For 34951A And L4451A D / A Converter
34951T
Terminal Block
Provides a flexible method for connecting discrete external wiring; detachable with screw-type connections.
-
Product
PCI to PXI Remote Control Kit
41-921-001-KIT
Remote Control Interface
This kit provides a seamless connection between a control PC’s PCI interface and a PXI chassis. The PCI to StarFabric module (51-921) resides in one of the controllers PCI slots and provides two independent StarFabric serial interfaces, each capable of driving a separate PXI chassis.
-
Product
PXI Isolated Single Channel Voltage/Current Source, 100V
M9186A
Source Measure Unit
The V/I source lets you source a voltage and measure the resultant current, or source a current and measure the resultant voltage. It consist of two separate amplifiers, denoted "low" and "high" that share a common output connection. The "low" amplifier provides voltages in the range of 16 volts at up to 200ma and the "high" amplifier provides voltages in the range of 100V at up to 20mA.
-
Product
Terminal Block For 34938A 20-Channel 5 Amp Form A Switch
34938T
Terminal Block
Use Keysight's 34938T terminal block for the Keysight 34938A 20-channel 5-amp form A switch for discrete wiring. It supports up to 20 AWG wire size typical for < 100 connections or 24 AWG for > 100 connections. The 34938T terminal block is detachable with screw-type connections that provides a flexible method for connecting external wiring.
-
Product
Configuration Block For The 34934A Quad 4x32 Reed Matrix
34934C
Terminal Block
This configuration block provides flexible options for wiring rows and columns to D-Sub connectors.
-
Product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-112
Fault Insertion Unit
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
NI TB-2646B Terminal Block for NI 2532B as 1-Wire Quad 4x32 or 2-Wire Dual 4×32 Matrix Matrix Topology Without Column Protection Resistors
782385-13
Terminal Block
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.





























