Remote Terminal Unit
Collects data from data acquisition (DAQ) devices and transmits the information to the main test system via a network.
-
Product
Source Measure Units
NGU
Source Measure Unit
Thanks to their extremely high accuracy and fast load recovery time, the R&S®NGU source measure units (SMU) are perfect for challenging applications. A special ammeter design is used to precisely measure current drains from nA to A in one pass – no need to make multiple measurement sweeps. The instruments’ short recovery times enable them to handle fast load changes that occur, for example, when mobile communications devices switch from sleep mode to transmit mode. With high speed data acquisition, every detail is detected down to 2 μs resolution.
-
Product
RM-24999, 96-Pin Female DIN to 10-Pin Female RJ50, Rack Mount Terminal Block
785840-01
Terminal Block
96-Pin Female DIN to 10-Pin Female RJ50, Rack Mount Terminal Block - The RM-24999 provides RJ50 connectivity in a 1U rack-mount form factor for up to three bridge input modules. You can use SH96F-96M-5 Sensor Cables to connect to the PXI Express bridge input modules.
-
Product
Autonomous Driving AI Decision Making ECU
ADM-AL30
Electronic Control Unit
ADM-AL30 is dedicated to Autonomous Driving Applications. Powered by Intel® 12th Gen Core i9/i7 CPU and the NVIDIA RTX 4000 SFF Ada GPU, this AI computing platform can process huge amounts of data and make crucial decisions for autonomous vehicles. Equipped with 2 x 10G Base-T and 8 x 1G Base-T1 automotive ethernet ports, as well as 8 x CAN FD and 4 x CAN 2.0 interfaces, it seamlessly integrates into any automotive ecosystem. Plus, its ISO 16750-2 and ISO 7637-2 ensure reliability and safety under the most demanding conditions.
-
Product
Motion Control Terminal Board For Panasonic MINAS A4 Servo Amplifiers
DIN-814-A40
Terminal Board
- Panasonic MINAS A4 super servo- Dimensions: 123 mm x 107 mm x 44 mm (WxLxH)- Available for PCI-8174, PCI-8164, PCI-8154, PCI-8158 and PCI-8134
-
Product
Dual Function Slot MOSA Data Concentrator Unit (DCU)
NIU2A-DCU-01
Data Concentrator Unit
NIU2A-DCU-01 is a Modular Open Systems Approach (MOSA) Data Concentrator Unit with low power high performance ARM Cortex -A9 processing. 512 MB RAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet and optional Fiber Optic Ethernet support
-
Product
TB-2676, Ribbon, 100 V, PXI Module Multiplexer Terminal Block
779535-01
Terminal Block
Ribbon, 100 V, PXI Module Multiplexer Terminal Block - The TB-2676 features ribbon cable headers that help you access all channels of the PXI-2576 Multiplexer Switch Module. You can use the TB-2676 to configure the 16 banks of 4x1 2-wire multiplexers included with the PXI-2576.
-
Product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A, Hardware Interlock
40-194A-002-HI
Fault Insertion Unit
The 40-194A-002 is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
Optical/Electrical Clock Recovery
N1077A
Clock and Data Recovery Unit
50 MBaud to 32 GBaud data rate range (continuous) on optical and electrical designs Provides standards-compliant clock recovery (CR) for NRZ and PAM-4 data signals Yields flexible, compact, high-sensitivity CR design with an integrated amplified optical-to-electrical (O/E) converter Gain optimal ease-of-use with integrated splitter and bulk optics coupler (Option SMS)
-
Product
Two-Quadrant SMU For Battery Drain Analysis, 20 V
N6781A
Source Measure Unit
The Keysight N6781A is a source / measure unit (SMU) designed specifically for the task of battery drain analysis. Whether the device under test (DUT) is an eBook reader, MP3 player, mobile phone, or pacemaker, the N6781A’s seamless measurement ranging, programmable output resistance, and auxiliary DVM combine the best set of advanced features on the market for battery drain analysis. When used with the 14585A Control and Analysis software, the N6781A becomes an even more powerful battery drain analysis solution, offering additional insights into your measurements. Learn more about the 14585A Control and Analysis software.
-
Product
PXI 34-Channel 4-Bus 2A Fault Insertion Switch
40-197A-001
Fault Insertion Unit
This 34-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers. A low cost 16-channel option is also available.
-
Product
EBIRST 100-pin SCSI Termination Fixture
93-019-104
Termination Fixture
93-019-104 eBIRST Termination Fixture is part of a range of USB controlled test tools capable of performing automated path resistance tests on Pickering Interfaces PXI, LXI or PCI controlled switching solutions. Each tool simply interfaces with the switching system's connector so a test can be run using the supplied Windows-based software.
-
Product
Optical / Electrical Clock Recovery
N1078A
Clock and Data Recovery Unit
N1078A Optical/Electrical Clock Recovery provides standards-compliant clock recovery capabilities for single-mode optical as well as electrical signals from 125 MBd up to 64 GBd PAM4 and NRZ
-
Product
TB-2635, Screw Terminal, 8x16, 2-Wire PXI Module Matrix Terminal Block
778839-01
Terminal Block
Screw Terminal, 8x16, 2-Wire PXI Module Matrix Terminal Block - The TB-2635 provides the necessary routing to configure the PXI-2529 PXI Matrix Switch Module as a 2-wire 8×16 matrix. You can directly connect the TB-2635 to the front panel I/O connectors of the PXI-2529. The TB-2635 includes screw terminals that provide access to the rows and columns of the matrix.
-
Product
PXIe-4138, 60 V, 3 A System PXI Source Measure Unit
782856-01
Source Measure Unit
±60 V, 3 A System PXI Source Measure Unit—The PXIe‑4138 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4138 features 4-quadrant operation. The PXIe‑4138 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.
-
Product
PXI Single Bus 64-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-401
Fault Insertion Unit
The Single Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
NI TB-2627 Screw Terminal Block for NI PXI-2527
779358-01
Terminal Block
The TB-2627 provides the necessary routing to configure the PXI-2527 or PXIe-2527 PXI Multiplexer Switch Modules as a single or dual 1-, 2, or 4-wire multiplexer. You can directly connect the TB-2627 to the front panel I/O connectors of the PXI-2527 or PXIe-2527.
-
Product
Battery Fault Insertion Unit
Fault Insertion Unit
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
Product
Terminal Block For 34952A And L4452A Multifunction
34952T
Terminal Block
The Keysight 34952T is a terminal block for the 34952A and L4452A Multifunction with 32-bit DIO, 2-ch D/A and Totalizer. This terminal block is used for discrete wiring. It supports up to 20 AWG wire size typical for <100 connections or 24 AWG for >100 connections. The 34952T is a detachable terminal block with screw-type connections that provides a flexible method for connecting external wiring.
-
Product
TB-2648, Screw Terminal, 4x128, 1-Wire PXI Module Matrix Terminal Block
781131-01
Terminal Block
Screw Terminal, 4x128, 1-Wire PXI Module Matrix Terminal Block - The TB-2648 provides the necessary routing to configure the PXI-2531 or PXIe-2531 PXI Matrix Switch Module as a 1-wire 4x128 matrix. You can directly connect the TB-2648 to the front panel I/O connectors of the PXI-2531 or PXIe-2531.
-
Product
PXI 11-Channel 2A Fault Insert Switch
40-202-101
Fault Insertion Unit
This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
Product
3U cPCI Sensor Interface Unit
SIU31
Sensor Interface Unit
NAI's SIU31 is a highly configurable rugged COTS system or subsystem ideally suited for military, industrial, and commercial applications that require high-density I/O, communications, Ethernet switching, and processing. The SIU31 uses one NAI field-proven, 3U cPCI board to deliver off-the-shelf, SWaP-optimized COTS solutions that "Accelerate Your-Time-to-Mission."
-
Product
96-Pin Female DIN to 88-Pin Female Screw Terminal, 10 V, PXI Module Mount Terminal Block
781347-01
Terminal Block
NI TB-4330 Terminal Block for PXIe-4330
-
Product
PXI MultiComputing Remote Control Module
Remote Control Interface
PXI MultiComputing Remote Control Modules enable PXI systems to transfer data at multigigabytes per second with only a few microseconds of latency. You can use these models in applications such as real-time tests, hardware-in-the-loop (HIL) tests, and structural tests that need a large number of distributed PXI systems to share data with low latency.
-
Product
NI TB-2642B Terminal Block for NI 2532B as 1-Wire 16x32 Matrix Topology Without Column Protection Resistors
782385-05
Terminal Block
The TB-2642B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 1-wire 8x64 matrix. You can directly connect the TB-2642B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2642B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
Source Measurement Unit
SMU32
Source Measure Unit
The SMU32 is a low cost solution for V/I source and measurement. The SMU32 offers PMU/DPS in a compact, 3U PXI form factor. The SMU32 supports -1V to +10V +- 32 mA FVMI/FIMV modes. 8~32 PMUs can be ganged to DPS for high current driving.
-
Product
PXIe 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
42-205-008
Fault Insertion Unit
42-205-008 (PXIe) is a 8-channel fault insertion switches designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. They available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
Digital Source Capture Unit
DIO2
Capture Unit
The DIO-II module is a multimode digital source and capture unit. In Low Speed Mode it provides a 20-bit parallel or 24-bit serial I/O capability running at speeds up to 50 MHz. In High Speed Mode, the DIO-II provides a 16-bit parallel I/O capability up to 200 MHz. In both Modes, the Clock is generated by a low jitter PLL source that is capable of generating clocks from 320 kHz up to 1 GHz.
-
Product
48-Ch 2A-250VAC 2-Bus Fault Insertion
YAV90076
Fault Insertion Unit
48 channels2A 250V 2 Fault Insertion BusesSwitching up to 60CAN Control (or Ethernet with Ethernet to CAN Gateway)Drivers dll & VIs available
-
Product
Optical/Electrical Clock Recovery
N1077B
Clock and Data Recovery Unit
N1077B Optical/Electrical Clock Recovery provides standards-compliant clock recovery capabilities for multimode and single-mode optical as well as electrical signals from 125 MBd up to 64 GBd PAM4 and NRZ
-
Product
TB-2636, Screw Terminal, 4x32, 2-Wire PXI Module Matrix Terminal Block
196762-01
Terminal Block
The TB-2636 provides the necessary routing to configure the PXI-2529 PXI Matrix Switch Module as a 2-wire 4×32 matrix. You can directly connect the TB-2636 to the front panel I/O connectors of the PXI-2529. The TB-2636 includes screw terminals that provide access to the rows and columns of the matrix.





























