Thermocouple Calibrators
-
Product
Multi-function Desktop Calibrator
VA730
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Multi-function Desktop calibrator DC Voltage/Current Source.
-
Product
K Thermocouple Immersion Probe
TP750
-
Immersion “K” Type thermocouple probe. Tolerance according to IEC 60584-2 standard.
-
Product
Thermocouple System
Model TCIC
-
Industrial Measurement Systems Ltd.
High Speed 8 Channel Thermocouple Interface CardPDF VersionModel TCIC Thermocouple Interface Card with USB or RS232 / 485Main FeaturesLow cost high speed thermocouple measurement 400 channels / second
-
Product
Dry-Well Calibrators
-
Electronic Development Labs, Inc.
Portable, highly stable, and precise heat sources used to calibrate, test, and verify temperature sensors—such as thermocouples and resistance thermometers (RTDs)—without using oil or liquid baths.
-
Product
Resistor Calibration Boxes
RCB-1
-
Standard Electric Works Co., Ltd
● The RCB-1 is used to verify and proof any High Voltage Insulation Testers. It can be utilized to calibrate all High Voltage Insulation Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator too, therefore, SEW started manufacturing the RCB for special customers.
-
Product
Three Phase Portable Energy Meter Calibration Equipment
GF302D1
-
Beijing GFUVE Electronics Co.,Ltd.
The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.
-
Product
Calibration
Field Probes
-
We calibrate following types of field probes:Electric field probesMagnetic field probesFlux density metersRadiation monitorsNear field probes
-
Product
MAX31855 J-Type Thermocouple Sensor Breakout
SEN-30003-J
-
Breakout board for the MAX31855J digital thermocouple interface ICs by Maxim. Measured temperature range is -210C-1200C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 2x5 pin header (8-pins used), has four vertical mini thermocouple connectors and four mounting holes for standoffs and 4-40 screws. The SEN-30003 is interfaced via 3 or 4-wire SPI with a data-ready output for specific operating modes. An LDO and a high-speed level shifter are included to allow interfacing with microcontroller devices between 3.0V and 5V (all Arduinos, Raspberry PI, etc) without sacrificing device performance (many other level shifters reduce data rates to below 500 kHz).
-
Product
Air Pollution Multigas Calibrator
APMC-370
-
Dilution of gases with high accuracy and precision requires high quality MFC’s, especially for high dilution ratios and ranges. Consequently HORIBA’s APMC-370 is equipped with digital MFC’s. These MFC’s are factory calibrated, optional also with a special Polynomial Calibration. HORIBA Europe‘s APMC-370 is designed to calibrate gas analyzers manually, remotely controlled or automatically. It is installed in air pollution monitoring stations for quality assurance in the laboratory and also in the production of gas analyzers.
-
Product
Voltage And Current Calibrator
-
Precision Mastech Enterprises Co.
A precision instrument designed to generate (source) and measure precise electrical signals.
-
Product
Thermocouple Thermometer 1 Input
HD2108.1
-
Thermocouple thermometer with one input for K, J, T, R, N, S, B, E type probes with miniature connector.
-
Product
Thermocouple Power Sensors
N8482B
-
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.
-
Product
One Phase Electric Power/Energy Calibrator
MC133
-
The MC133 master unit model is a one phase electric power/energy calibrator. It can supply the device under test with single phase precise voltage and current with calibrated phase shift along with DC voltage and current capability. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A. Simulated electric power can be set independently for each phase. Frequency can be set from 15Hz to 1 kHz with resolution 0.001Hz to 0.01Hz. The MC133 Calibrator is equipped with 5 1/2 digital DC meter with DC ranges 20mA or 10V for direct calibration of various types of power transducers and wattmeters.
-
Product
Humidity Calibration Cell
-
Humidity calibration involves checking the accuracy of and making the proper adjustment to sensors that measure moisture content in the air.
-
Product
MAX31855 J-Type Thermocouple Sensor Breakout
SEN-30001-JDP
-
Breakout board for the MAX31855J digital thermocouple interface IC. Measured temperature range is -210C-1200C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 1x5 pin header and four mounting holes for standoffs and 4-40 screws. It does not contain a mini thermocouple connector.
-
Product
Reference Temperature Calibrator
JOFRA™ RTC-187
-
AMETEK Sensors, Test & Calibration
RTC-187 provides high-quality temperature measurement from -45 to 180°C. The 180°C is a 25° expansion over the range of the RTC-157, and it’s now the hottest temperature available for a calibrator that also supplies cold temperatures.
-
Product
Photometric Ozone Calibrator
Model T703
-
Teledyne Advanced Pollution Instrumentation
The Model T703 is a microprocessor controlled ozone calibrator for precision gas analyzers. The Model T703 can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM.The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperate and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703, covering time periods up to a year.
-
Product
Calibration
-
During the recent years we have made scientific investigations regarding calibration procedures, which have been published and integrated in the European and International standards. The calibration of antennas and field probes in Seibersdorf is done on the reference open area test site, in three different TEM-Cells and in the fully anechoic chamber. The open area test site is one of the best in Europe. Since 1996 we are the accredited calibration laboratory according to Akkreditierung Austria 0612 for antennas and field probes.
-
Product
Gauge Type T Thermocouple Wire
W-TW-44P2
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Automated Pressure Calibration System
4322
-
The Fluke Calibration 4322 Automated Pressure Calibration System enables almost any user to calibrate almost any pressure gauge, transducer, transmitter or switch, including vacuum, compound, absolute and high-pressure devices. It provides high-end, laboratory-grade performance across a very wide range, on the bench or in situ.
-
Product
Frequency Extension Calibration Kits
FEK
-
Farran’s FEK-xx-0001 calibration kit provides accurate calibration of the Vector Network Analyzer (VNA). It is compatible with TRL and SOLT calibration techniques and allows for a full 12-term port calibration.
-
Product
Loop Calibrator
6500 LC
-
Standard Electric Works Co., Ltd
● 4-20mA (1kΩ load, 24V Loop Supply).● 0.025% Basic Accuracy.● Simple Operation Interface.● Auto Ramp and Step Functions.● 0-20mA, 0-24mA selectable.● Incremental percentage setting : 0-100%.● Warning beeper when output is open.● 0-24V output.● The minimum load of 20kΩ on voltage mode.
-
Product
Acoustic Calibrators
-
We offer a range of Class 1 and Class 2 acoustic calibrators for the field calibration of any make or model of sound level meters and noise dosimeters.
-
Product
Instrument Transformer Calibrators
CTPT 81
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
Product
Calibration Kit
F7511
-
F7511 Calibration Kit, Frequency Range: up to 3 GHz, Impedance: 75 Ohm, Connector type: F-type
-
Product
Humidity and Temperature Calibration
-
The most comprehensive temperature, humidity and dew-point calibration offering on the market today.
-
Product
Thermocouple Thermometer – 2 Inputs – Data Logger
HD2128.2
-
Thermocouple thermometer for probes type K, J, T, R, N, S, B, E, two inputs.
-
Product
Furnace Calibrators
-
Electronic Development Labs, Inc.
High-precision heating instruments designed to calibrate temperature sensors.
-
Product
Standard Ratio Box For Calibration
ST-105
-
The ST-105 is a calibration box with standard ratios. It is used for calibration of any turn ratios measurement system. Housed in a rugged, waterproof case, it is very lightweight.
-
Product
Calibration
-
To measure a wide range of pressure in an explosive endangered area the range of pressure modules is extended with 8 ATEX compliant models.