Thermocouple Calibrators
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
Electronic Calibration Module
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Basic Quad J-Type Analog Thermocouple Amplifier
SEN-30103-J0
-
Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.
-
Product
MAX31855 K-Type Thermocouple Arduino Shield
SEN-30004-K47
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino. The MAX31855K supports a measured temperature range of -270C-1372C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
Automated Pressure Calibration System
4322
-
The Fluke Calibration 4322 Automated Pressure Calibration System enables almost any user to calibrate almost any pressure gauge, transducer, transmitter or switch, including vacuum, compound, absolute and high-pressure devices. It provides high-end, laboratory-grade performance across a very wide range, on the bench or in situ.
-
Product
Optical Power Meter W/6 Wavelength Calibrating Spots
-
With six wavelength calibrating spots (980nm, 1310nm, 1490nm, 1550nm, 1590nm and 1610nm), refined design, easy operation, linearity or non-linearity display, SC connector, the MXOPM26-50 hand-held optical power meter can be used for direct optical power measurement as well as relative measurement of optical link loss. It’s an essential test instrument in Optical Communication systems, CATV systems, construction and maintenance applications and more.
-
Product
Ralston Quick-test™ Microbore Calibration Hoses
-
Ralston Instruments Quick-test™ hoses can be attached and detached without a wrench or thread sealant while maintaining a working pressure of 6900 psi (475 bar). Quick-test hoses are small in diameter, flexible, and low in volume. These hoses provide an ideal way of transmitting pressure during a vacuum or pressure calibration. A wide variety of adaptors provide a connection for most calibration applications.
-
Product
Universal Solution for Model-based Calibration Software
INCA
-
INCA tools are used for ECU development and test as well as for validation and calibration of electronically controlled systems in the vehicle, on the test bench, or in a virtual environment on the PC. The tools are used worldwide in over 20,000 installations in development and production projects.
-
Product
Vibration Transducers Calibration System
-
The system is used for calibration of vibration transducers as well as:*ICP and charge accelerometers;*piezoelectrical and capacitive vibration transducers;*vibration-measuring instruments.
-
Product
Calibration Measurement
-
The process of comparing a measuring instrument's readings to a known, more accurate standard to detect and correct errors.
-
Product
J-Type Thermocouples Wire, Fiberglass (32 deg F to 900 deg F) 1 m
745690-J001
-
J-Type Thermocouple, 32°F to 900°F Temperature Sensor - The J-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the J-Type Thermocouple and acquire synchronized temperature data in units of degrees. The J-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
ACCUplace Macro Calibration Standard
AP-M Series
-
With both X & Y axis metric scales, these dual axis targets are ideal for calibrating optical magnification in microscopes, linear distance, stage motion and squareness. In addition, with the larger area calibration scale, the calibration of low power optical systems over the longer distances can be easily carried out. The AP-M is offered on two standard materials; Glass (CG) and Opal (OP).
-
Product
Test gas - for calibration
-
Test gases for gas measuring and gas warning devices.Enables the functional control and calibration of measurement technology.
-
Product
Thermocouples
-
A thermoelectric device for measuring temperature, consisting of two wires of different metals connected at two points, a voltage being developed between the two junctions in proportion to the temperature difference.
-
Product
12:1 IR Thermometer w/ K-Type Thermocouple Input
INF195C
-
UEi Test & Measurement Instruments
The INF195C offers the unique circular laser targeting showing users the exact spot being measured. This 12:1 Infrared Thermometer also offers advanced features including a wider temperature range, K-Type input, selectable emissivity levels, Min/Max, average, differential, a user adjustable alarm and backed by a 1-Year limited warranty.
-
Product
IR Calibration Instruments
-
Bodkin Design & Engineering, llc
We offer a line of comprehensive solutions to address all of your thermal calibration needs. From bench-top differential sources with .01° C resolution for experiment calibration to built-in OEM devices for on-the-fly thermal reference, Bodkin Design and Engineering and IRBlackbody have the right blackbody for you.
-
Product
Electrical Calibration
-
All calibrations include as Found/as Left data, Measurement Uncertainity, Calibration Sticker, Calibration Certificate and online access to calibration data at NO additional charge.
-
Product
Mineral Insulated Thermocouples IEC
-
Durable Mineral Insulated type thermocouples to suit a wide range of temperature measurement. Various probe types, lengths and diameters available.
-
Product
Resistor Calibration Box
RCB-411
-
Standard Electric Works Co., Ltd
● The RCB-411 is used to verify and proof High Voltage Insulation Testers. Both Analogue and Digital Insulation Testers can be calibrated.● Caution: a. Before testing, make sure the front panel, terminals are clean and dry. If not, wipe them with cloth. b. Use high voltage silicone wires. Otherwise the reading will be incorrect.
-
Product
Air Data Calibration
-
Fluke calibration offers digital pressure monitors, air data calibrators and laboratory standards for air data pressure range calibrations. Each of these systems feature pressure ranges, measurement units and features specific to calibrate air data test sets and RVSM compliant air data instruments. Models include 2468 Ruska and ADCS-601 DHI primary level standards; 7750i Ruska air data controller/calibrator and RPM4-AD DHI reference pressure monitor.
-
Product
Thermocouple & Fine Wire Welder
L60
-
The Thermocouple Welder, manufactured by Labfacility, is a compact, simple-to-use instrument designed for thermocouple and fine wire welding.
-
Product
Microphone Calibrators
Trig-Tek™ 402H & 402PSI
-
Portable, self-contained, high-intensity acoustic microphone calibration source
-
Product
Electrical Test Equipment Calibrators
-
The industry leading series provides by far the fastest and safest solution for calibration of Loop, RCD, PAT's and insulation testers.
-
Product
Gauge Type T Thermocouple Wire
W-TW-30
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
RH Calibrator / Dew Point Generator
-
Edgetech Instruments'' portable calibration system offers the highest accuracy available for both relative humidity and temperature. Using chill mirror technology and precision PRT's, Edgetech''s calibrators offer best repeatability, stability and reliability when measuring RH and temperature. The calibrators are used mainly by calibration labs as a reference standard.The Edgetech Instruments dew point generator, DewGen, another calibration lab favorite, can be used as a stand alone or with a NIST traceable chill mirror dew point system creating very accurate dew points or frost points. Depending on the dry gas source this generator can create dew points from +15C to -80C.
-
Product
Calibrators
-
Our high accuracy calibrators work with all competitor products and offers the customer a way to maintain their equipment, while keeping the specifications of their process.
-
Product
Analyzer Calibration Extender
ACE
-
The ACE-1000A is a calibration solution that allows customers to self-calibrate their Kaelus PIM analyzers in the field. With successful calibration, ACE will extend your analyzer’s calibration while reducing downtime to less than one hour and increasing productivity by retaining instruments in the field.The Kaelus software guides the user through the calibration process from testing through payment including extending the calibration date of each Kaelus PIM Analyzer to 12 months, and printing the Certificate of Calibration certificate (CoC)
-
Product
Thermometer Calibration
-
In addition to the vast array of Thermometers that Comark has an offer, We also offer a range of devices to assist you with Thermometer Calibration.
-
Product
Multifunction Calibrators
-
To automate and optimise the calibration process Time Electronics' EasyCal Calibration Software can be used with compatible multi product calibrators. Increase speed of calibration, consistency of results and produce calibration certificates and reports to ISO 9001, ISO 17025, and other quality standards. With comprehensive features it provides the ideal platform for an efficient calibration program.
-
Product
Calibration Kit
S911T
-
*S911T Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: 3.5 mm female.
-
Product
Isolated Thermocouple Input Module
ADAM-3011
-