Thermocouple Calibrators
-
Product
MAX31855 J-Type Thermocouple Arduino Shield
SEN-30004-J47
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino. The MAX31855J supports a measured temperature range of -210C-1200C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
Conformance Calibration Standard Test Card for UPC/EAN Symbol Verifiers
AI-CCS-UPC/EAN-E Rev S
-
For those who prefer a traditional vertical format calibration test card, APPLIED IMAGE offers our new Conformance Calibration Standard Enhanced for UPC/EAN Bar Code Symbol Verifiers. The new standard complies with both the ANSI X3.182 and ISO 15416 standards and is ideal for testing of verifiers, scanners, and other UPC bar reading equipment as well as a tool for training new operators to assure proper “methodology' in the use of verifiers.
-
Product
Calibration Tool
Software
-
The smartGAS Calibration Tool is a commercial software company that makes it possible to interact with all smartGAS sensors of the EVO series with firmware version 5.17 or higher. With the smartGAS Calibration Tool, it can be read out and the zero point and the end point can be used with a suitable test gas.
-
Product
CNC Rotary Axis Calibrator
API Swivelcheck
-
API SwivelCheck is light-weight & comes with a convenient carrying case to easily transport & install on a variety of CNC machines.
-
Product
ECPR System (Electrically Calibrated Pyroelectric Radiometer)
Rs-5900
-
Developed in conjunction with NIST, the Rs-5900 ECPR is a ±1% absolute accuracy radiometric transfer standard for the visible to near-IR (0.25-2.0µm), with the RsIR Option extending the ±1% accuracy to >20µm. The RsP-590 Pyroelectric Probe requires no cooling and maintains ±1% accuracy from 1 µW to 100 mW. The ECPR uses an auto-nulling, electrical substitution technique that allows the instrument to be referenced against NIST electrical standards, insuring maximum accuracy and precision. Unlike most electrically calibrated radiometers, there is a direct correlation between electrical and optical heating because the same material serves as both the optical absorber and electrical heating element.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16
85038A
-
The Keysight 85038A calibration kit contains open circuits, short circuits and terminations with both male and female 7-16 connectors and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Trace Level Portable Gas Calibrator
Model T750U
-
Teledyne Advanced Pollution Instrumentation
The Model T750U is a portable, microprocessor based calibrator for precision trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.
-
Product
Eight-channel USB Voltage and Thermocouple DAQ
Model DI-2008
-
Includes DI-2008 instrument, WinDaq software, calibration certificate, terminal screwdriver, and USB cable (6-feet). Eight differential and isolated analog input channels. Seven bi-directional digital input ports, including: Counter input for totalizing applications, Rate input for frequency/flow/rpm applications. ChannelStretch™ channel expansion to 128 analog and 112 digital channels. Programmable voltage and thermocouple measurements per channel. 10 mV to 50 V programmable range per channel in 12 steps.
-
Product
Decade Box, Calibrated W/D & U, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL DU
-
The 72-7270 CAL DU from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Digital Light Meter, Calibrated
93-172-C
-
Measures incandescent, fluorescent, metal halide, high-pressure sodium and halogen lampoutput. Color and cosine-corrected for enhanced accuracy. Measures up to 50,000 lux. Peak and data hold means no lost measurements. Accessories included: (1) 9V battery and carrying case. Lifetime Limited Warranty.
-
Product
Universal Solution for Model-based Calibration Software
INCA
-
INCA tools are used for ECU development and test as well as for validation and calibration of electronically controlled systems in the vehicle, on the test bench, or in a virtual environment on the PC. The tools are used worldwide in over 20,000 installations in development and production projects.
-
Product
Instrument Calibration Services
-
Instrument Calibration ServicesCalibration is a fundamental step in the process of measurement. It ensures that the instrument used for testing accurately indicates the required measurement parameter and that the instrument is performing to its specification.
-
Product
Kit, Cable Assembly, SH-37F-OM6/4, 9219 Calibration Cable Kit
146907-01
-
Kit, Cable Assembly, SH-37F-OM6/4, 9219 Calibration Cable Kit
-
Product
Furnace Calibration
-
Tempsens Calibration Centre offers calibration of wide ranges of Furnaces at site and at our lab.
-
Product
K Thermocouple Surface Probe
TP772
-
Surface thermocouple Type "K" probe. °C max: 400. Response time: 3 s.
-
Product
Calibrated Solar Reference Cell
-
To insure repeatable testing on any solar simulator, OAI offers 2cm x 2cm calibrated reference cells. Standard reference cell calibration cycles can be set up by OAI''s calibration laboratory to insure that your reference cell maintains certification.
-
Product
K Thermocouple Surface Probe
TP754
-
Surface thermocouple Type “K” probe. Tolerance according to IEC 60584-2 standard.
-
Product
Power Measurement And Calibration
-
Portable, rugged and battery operated, Arbiter Systems® Power System Analyzers are revolutionizing measurements of instrumentation, relaying and metering circuits. Built with safety-first in mind, all products include multiple grounding technologies to protect against shock. Software and firmware is available to manage and analyze the data in real-time or post-analysis via computer.
-
Product
NIST Calibration for D410-A
D410-A-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
VNA Calibration Kits
-
Vector Network Analyzers are commonly used to accurately determine the RF Characteristics of microwave components. Accurate Testing of microwave circuits means eliminating measurement errors and ensuring repeatable results. This is only possible when the network analyzers can be calibrated with known and true calibration standards.
-
Product
Thermocouple Bench Selector Switches 6 or 12 Way IEC, ANSI
-
A 6 or 12 way selector in a moulded housing with aluminium front and rear panels. The rear inputs are switched via a front mounted rotary selector switch to the single output socket. Internally wired with thermocouple compensating cable and available with IEC or ANSI thermocouple types K, J, T, N & R/S.
-
Product
Qualified Hermetic EGT Thermocouple Upgrade
-
FIT-IT & FORGET-IT Eliminate Exhaust Gas Temperature (EGT) thermocouple concerns with AMETEK's new EGT thermocouple product offering for Frame turbine applications. AMETEK has worked closely with the turbine OEM to design and engine test this thermocouple as a direct replacement and upgrade for all new and existing EGT thermocouples. The new EGT thermocouples are qualified and meet all design specifications.
-
Product
Thermocouple – Pt100 Thermometer Data Logger
HD2178.2
-
Thermometer with two inputs, the first for Pt100 sensor for input of probes equipped with SICRAM module, and the second input for thermocouple type K, J, T, E, N
-
Product
Calibrator for Battery Charger-Analyzers
VCM-100
-
The VCM 100 is an instrument designed to verify the performance and to calibrate Battery Charger-Analyzers used on Nickel-Cadmium, Lead-Acid and other types of batteries.
-
Product
K-Type Thermocouples Wire, Fiberglass (32 deg F to 900 deg F) 1 m
745690-K001
-
K-Type Thermocouple, 32°F to 900°F Temperature Sensor - The K-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the K-Type Thermocouple and acquire synchronized temperature data in units of degrees. The K-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
Calibration Sources
-
Up to an absolute accuracy of 60 MHz standard HighFinesse Wavelength Meters feature auto-calibration by integrated calibration sources. This way highest accuracy and stability of measurements with our wavemeters is guaranteed.
-
Product
Tool, Locator, Thermocouple, Receiver
910104134
-
Used with Crimp Tool Part # 910101102 to crimp thermocouple receiver contacts.
-
Product
Multiport Calibrated Measurements With Switch Instruments
S95553B
-
This application provides a macro which enables full multiport error correction and measurement capabilities using external switch instruments such as the M9164A/B or M9165A/B PXI Solid-state Switch Matrix. The software includes an easy-to-use measurement wizard that simplifies measurement procedures and reduces the setup time of complicated multiport measurements. The VNA displays measured multiport S-parameters.With the combination of M980xA PXIe VNAs and M916xA/B switch matrix, up to 66 ports (2 VNAs (4 ports and 6 ports M980xA), plus 4 modules of 2x16 M9164A/B) can be configured and supported. Measurement specification is supported when using the M9164B/M9165B 9 GHz switch modules.
-
Product
Current & Voltage Sources for Calibration of Measuring Systems and Sensors
-
ChenYang Technologies GmbH & Co. KG
*DC/AC Current: 0-60A *DC/AC voltage: 0-1000V frequency 50Hz, 60Hz, 400Hz, 1kHz
-
Product
16 Channel Isolated Thermocouple And Voltage Measurement Instrument
EX1401
-
The EX1401 delivers accuracies of ±0.20°C, 1000 V channel-channel isolation, built-in self-test capabilities, and independent 24-bit ADC’s per channel. Its ability to acquire data at 20K samples/second/channel allows its usage in high-speed temperature transient applications. Deploy it in a variety of applications, including automotive and battery testing, jet engine testing, highly accelerated life test/highly accelerated stress screening (HALT/HASS), and health monitoring. It can be used in any test environment that requires accurate temperature measurement and repeatability. Parallel data storage and standalone autonomous operating modes further expand the utility of this versatile instrument.