Thermocouple Calibrators
-
Product
Current Probe Calibrator
KSZ
-
PMK Mess- und Kommunikationstechnik GmbH
Since Current Probes are often exposed to hard working conditions, a performance check is recommendedbefore every use. These Current Probe Calibrators generate square wave pulses from 0.05 A to 1000 A with an accuracy better 1%. They qualify for calibration and adjustment of Current Probes.
-
Product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
Calibration Cable
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
Product
Oscilloscope, Calibrated, 2 Channel, 100 MHz, 1 GSPS, 25 kpts, 3.5 ns
72-8710A CAL
-
The 72-8710A CAL from Tenma is a digital storage oscilloscope with 100MHz bandwidth, 2 analogue channels. The digital storage oscilloscope provides a complete set of trigger modes including edge, pulse, alternate and storage modes including set-up, wave, bitmap. It has a 7 inches wide screen LCD display and supports plug and play USB storage device. Communication with and remote control of computer through the USB device.
-
Product
Gauge Type T Thermocouple Wire
W-TW-40P2
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Fine Wire Versatile Thermocouples ANSI
-
An exposed junction thermocouple is the simplest form of thermocouple. It consists of two pieces of thermocouple wire joined together with a welded bead. Since they can be made very small, an exposed junction thermocouple can provide a very fast response time.
-
Product
Temperature Calibration
-
Process Instruments maintains primary temperature standards for the calibration of Standard Platinum Resistance Thermometers. SPRT''s are measured against a Thomas-type Ten Ohm Standard Resistor (a Leeds & Northrup 4211-B), using a Measurements International automated bridge. Primary thermometry points are maintained at the Water, Tin, Zinc and Gallium points.
-
Product
Test & Calibration
-
Gamma Scientific is ISO/IEC 17025 accredited by NVLAP (NVLAP lab code 200823-0). In addition to assurance of measurement accuracy, accreditation ensures traceability to known standards, provides international acceptance of measured values, and is important for compliance purposes for your own ISO/IEC certifications. Our state-of-the-art, ISO 17025 accredited calibration laboratories in San Diego, California offer a range of test and calibration services including:
-
Product
Gauge Type T Thermocouple Wire
W-TW-36
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit
72-7770 CAL D
-
The 72-7770 CAL D from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.
-
Product
4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (m) 50 Ohm
CK518A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
PC Programmable, Suitable For Thermocouple Sensors
SEM206TC
-
The SEM206/TC is our entry level PC programmable temperature transmitter
-
Product
Spectral Radiance / Luminance Calibration Standards
-
Standard lamps calibrated in luminance and spectral radiance. Traceable calibrations in the wavelength range from 250 nm to 2500 nm.
-
Product
Gauge Type T Thermocouple Wire
W-TW-44P
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Standard Voltage 9 Pin D-Type Cables - Calibration Cables for Pickering Products
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 9-pin D-type calibration port connector.
-
Product
Instrument Transformer Calibrators
CTPT 81
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
Product
Pressure Calibrators
-
We offer pressure calibrators as portable and as workshop models. Pressure measurement is performed with internal and/or external pressure modules for better flexibility. Pressure measurement ranges go from vacuum up to 1000 bar (14,500 Psi). Both gauge (vacuum and positive) and absolute pressure can be measured with same modules meaning you don’t need to buy so many module for greater flexibility. Also, intrinsically safe pressure calibrators are available for use in hazardous areas.
-
Product
Calibrators
-
Fluke offers a wide range of pressure calibration tools with precision pressure measurement from 15psi/1 bar to 10,000 psi/690 bar boasting 0.025% full-scale accuracy. Everything from simple test gauges to calibrators with built in electric test pumps. Easy to use, rugged and reliable construction and an industry best 3-year warranty. Fluke means pressure.
-
Product
EMC Calibration
-
Trescal provides full EMC Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. EMC Calibration services can be delivered at your site or at our lab. Accreditations for our emc calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Thermocouple, Module, ITA, 90 Series, 64 Position
510108124
ITA Module
Primary mating module 510104133. (May mate with other Receiver modules, as well.)*Please note: VPC receiver modules must be separated into two pieces in order to extract contacts. For detailed instructions please consult the user manual/procedure sheet for this module before extracting contacts.
-
Product
100-Amp Current Calibrator And AC/DC Transconductance Amplifier
2555A
-
World’s Leading Precision 100-Amp AC/DC Current Standard - For 30 years Valhalla Scientific’s design has proven rock-solid reliability in metrology labs worldwide. The 2555A is a calibration powerhouse with wide-ranging applications and unsurpassed quality.
-
Product
Calibration Pulse Processor
2401
-
TESCO’s Calibration Pulse Processor (Catalog No. 2401) adapts to any Next Generation three phase test board to directly calibrate with three independent single phase standards.
-
Product
Service, Modernization, and Calibration Serivices
-
In addition to production of new material testing machines, TIRA offers inexpensive service, modernisation and calibration. Our modular design makes it possible to modernise complete measuring technologies, electromechanical and hydraulic material testing machines in a cost-efficient manner.According to all requirements of force-measuring systems DIN EN ISO 7500-1, calibration DIN EN ISO/IEC 17025 and test options according to EN 10002.
-
Product
Calibrate Camera RAW Image Files
SpyderCUBE™
-
Accelerate RAW processing by taking one reference shot under any light condition to set the white balance, exposure, black level and brightness right from the start for your entire series of photos.
-
Product
Calibrator for Battery Charger-Analyzers
VCM-100
-
The VCM 100 is an instrument designed to verify the performance and to calibrate Battery Charger-Analyzers used on Nickel-Cadmium, Lead-Acid and other types of batteries.
-
Product
16 Channel Isolated Thermocouple And Voltage Measurement Instrument
EX1401
-
The EX1401 delivers accuracies of ±0.20°C, 1000 V channel-channel isolation, built-in self-test capabilities, and independent 24-bit ADC’s per channel. Its ability to acquire data at 20K samples/second/channel allows its usage in high-speed temperature transient applications. Deploy it in a variety of applications, including automotive and battery testing, jet engine testing, highly accelerated life test/highly accelerated stress screening (HALT/HASS), and health monitoring. It can be used in any test environment that requires accurate temperature measurement and repeatability. Parallel data storage and standalone autonomous operating modes further expand the utility of this versatile instrument.
-
Product
Calibration Kits
-
Atec’s Portable Calibration Kit, PN AHT63506-1, is used to calibrate instrumentation and transducers in engine test cells, as required per T.O. 33K6-4-3416-1 or Atec Technical Manuals.
-
Product
PLTS Measurement And Calibration
N19303B
-
The new Physical Layer Test System (PLTS) 2024 is the industry standard for signal integrity measurements and data post‑processing high-speed interconnects, such as cables, backplanes, PCBs, and connectors. Signal integrity laboratories worldwide have benefited from the power of PLTS in the R&D prototype test phase.
-
Product
Acoustic Calibration
-
Trescal provides full Acoustic Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Acoustic Calibration services can be delivered at your site or at our lab. Accreditations for our acoustic calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Thermocouple Extension Lead
EXT-6
-