Ground
See Also: Earth, Soil, Ground Penetrating Radars
-
Product
3U 5-Slots OpenVPX P&G, w/o ROHS, 3.125G
101VPX305P-9004
-
3U 5-Slots OpenVPX Power & Ground, Pass through, RT2-R ruggedized conn, w/o ROHS, Max data rate (Gbps) 3.125.
-
Product
sbRIO-9264, Non-Enclosed, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module
781119-01
Voltage Output Module
Non-Enclosed, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module - The sbRIO‑9264 is a simultaneously updating analog output module that accommodates higher‑channel‑count systems. Higher density modules conserve chassis space, which leaves room for other measurement types. Each channel has its own digital‑to‑analog converter. The spring-terminal version of the sbRIO‑9264 uses a 36‑position connector for the output channels, and each channel has a ground connection. Non-enclosed modules are designed for OEM applications.
-
Product
Neon Transmitter
-
Shanghai Yiya Electronic Instrument Co., Ltd.
Asphalt resin filled and vacuum potted. Patented magnetic core at low consumption. Heavey duty metal box and coated power. User Friendly-Adapts to most grounding situations.
-
Product
PXI BRIC4 FIBO Matrix Dual 20x4 3pin brkout
40-592A-001
Matrix Switch Module
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
Product
Installation Testers
-
A Multi-Function installation tester is better then the single function meter. Good quality insulation, a properly working grounding system and active protection assure the safety of people, electrical systems and buildings, and protect them against electrocution, fire and other equipment damage and all of this can be checked by an HT Instruments Installation tester
-
Product
Fault Locator
VM-510FFL+
-
Finding the location of an underground cable fault just became easier with the VM-510FFL+ Standalone A-frame locator. Now locating a suspect cable and finding the fault can be done with the VM-510FFL+ and a compatible transmitter. There is no longer a need for a separate utility locator with cables connecting to it. After connecting a compatible transmitter to the line and placing it in a Fault-Find mode, use the simple to operate four button controls of the VM-510FFL+ to locate and stay on the cable path while pinpointing the sheath or ground fault.
-
Product
Transceivers
-
Macom Technology Solutions Holdings Inc.
At MACOM we offer monolithic and stereo Doppler transceivers for directional motion detection. Our transceivers are used in a variety of applications such as automatic door openers, ground speed recorders and police radars. MACOM’s transceivers are well suited for high volume applications where small size and reliability are required.
-
Product
Basic Quad K-Type Analog Thermocouple Amplifier
SEN-30103-K1
-
Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.
-
Product
Encoder And Decoder Unit
MS 2003
-
Encoder Decoder Unit is used to interact with ground station through PCM interface. Receives and transmits command/status information on Lakshya aircraft. Also provides real time clock synchronization, latitude/longitude information and IRIG-B Time. System is a digital, high speed FPGA controlled, intelligent unit to interact with various sub systems.
-
Product
Circbord
8007
-
VECTOR Electronics and Technology, Inc.
Pad-Per-Hole pattern on component side. Overall Ground Plane pattern on wiring side.0.080” diameter isolated solder pad around holes oncomponent side. Plane surfaces solder coated for user convenience.
-
Product
Isolation Adapter
-
For harsh environments and motor control applications where debug tools may be exposed to high voltage or ground loop potentials, Blackhawk offers two product models of galvanic isolation.
-
Product
Differential Probe
DP-40K
-
*MAX. Input Voltage: ±20KV DC or 40KV p-p or AC 14KV rms*Bandwidth: DC-20MHz*Input Impedance 100MΩ// 1PF*x500, x5000 Attenuator*To Ground MAX. Voltage: 10KV CAT III*Output Impedance 50Ω
-
Product
Gold Probes
4900 Series
-
The "GOLD PROBE" has been designed specifically for use with Tektronix, Hewlett Packard and other high performance oscilloscopes. This new slim design along with a host of versatile accessories, allows you to reach the most difficult test point in today's highly complex circuitry. The gold plated Probe Tips, Sprung Hook, Ground Lead, Alligator Tip and other critical interconnect points within the Gold Probe, provide excellent contacts for probing low level analog signals and high speed digital data. Unlike most "off shore" commodity probes, Probe Master guarantees quality and continuing domestic support for our "Made in America" Gold Probe.
-
Product
PXI BRIC4 FIBO Matrix Dual 60x4 3pin brkout
40-592A-003
Matrix Switch Module
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
Product
NI-9262, 1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module
785503-02
Voltage Output Module
1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module - The NI-9262 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. The NI-9262 module includes a channel-to-earth ground isolation barrier for safety and noise immunity.
-
Product
Digital Ior Leakage Current Clamp Tester
MCL-400IR+
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・About Ior Leakage CurrentRecently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).
-
Product
Universal Multichannel System up to 100V
-
- From 12 to 48 independently controllable High Voltage channels- 0 ÷ 100 V output voltage- Maximum Current: 1mA, 10 mA or 1 mA/100 μA (dual range board)- Individual Enable (A1510 only)- Either DB37, DB25 or SHV connectors- Available with either positive, negative or mixed polarity- Up to 20 nA / 100 pA current set / monitor resolution- Up to 2 / 0.2 mV voltage set / monitor resolution- Extreme Low ripple, down to < 3 mVpp- 3 different channel grounding- Common Ground (AGxxxx)- Common Floating Return (Axxxx)- Full Floating (A1510 only)- Independently programmable for each channel:- Output voltage- Current limit- Ramp up/down- TRIP parameter- Current generator operation in overcurrent condition- Specific design for double side silicon detector (A1510)
-
Product
PCI Express 16 Reed Relay Output
8004He
-
The 8004He PCI Express digital I/O interface provides 16 optically isolated inputs and 16 Reed relay outputs. The isolated inputs protect the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments. The outputs provide high quality, long-life, dry contact switch closures suitable for low-current applications.
-
Product
PXI BRIC4 FIBO Matrix Dual 124x4 2pin Brkout
40-592A-014
Matrix Switch Module
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines. Typical applications are in automotive and aerospace industries which involve safety or mission critical systems that have to behave predictably when cabling or sensor faults occur.
-
Product
POWER PROBE 4
PP401
-
*Electronic circuit and component tester that supplies battery ground and power along with 8 diagnostic testing modes to provide automotive technicians with detailed information on the circuits and signals being tested*Diagnostic Modes include: AC/DC Voltmeter, Ohmmeter, Frequency, Pulse width (Positive and Negative) Fuel Injector Tester, PCM/ECM Driver Tester and PPECT3000 Signal tracer*Tests for AC/DC voltage in 100ms and 50s resolutions, AC volts RMS and volts peak-to-peak, measure resistance, frequency and pulse width (negative and positive)
-
Product
Eurocard Plugbord
E220-6U-2
-
VECTOR Electronics and Technology, Inc.
6U x 220mm Eurocard size for 96-pin DIN connectors. Voltage and ground buses around board perimeter on both sides. Bus surfaces solder coated for user convenience. For solder, Wire-Wrap or mixed wiring methods. Row and column legends provided.
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
Fault Insertion Unit
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
Product
Differential Probe
DP-8V
-
*MAX. Input Voltage: ±4KV DC or 8KV p-p or AC 2.8KV rms*Bandwidth: DC-50MHz*Input Impedance 20MΩ// 2PF*x10, x100, x1000 Attenuator*To Ground MAX. Voltage: 4KV CAT III*Output Impedance 50Ω
-
Product
sbRIO-9215, Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Modul
780878-01
Voltage Input Module
Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9215 performs differential analog input. The sbRIO‑9215 contains NIST‑traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
Product
PXI/PXIe Battery Simulator Module, 4-Channel With V/I Readback
41-752A-012
Simulator
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 4-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
Product
3U 1-Slot OpenVPX P&G, w/ROHS, 10G
101VPX301P-9X22R
-
3U 1-Slot OpenVPX Power & Ground, Pass through, P2B & RP2B not loaded, w/ROHS, Max data rate (Gbps) 10.
-
Product
5mA High Accuracy Ground Fault Detector
HA-GFD
-
Our HA-GFD Current Probe is our most sensitive current probe, measuring down to 5 milliamps. Ideal for measuring leakage current and ground faults. Dual range allows measuring up to 200 amps in high accuracy.
-
Product
Earth Resistance Testers
-
Earth Resistance Tester is widely applied in ground resistance measurement, loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil field, architecture and industrial electrical equipment, etc. When measuring ground system with loop, there is no need to disconnect the ground wire without auxiliary electrode, which means safer and faster.
-
Product
Load Cell Transmitter
MODEL SST-HV
-
The SST-HV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-HV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-HV may be powered from 95-240 Vac ±10%. The SST-HV has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.