Earth
See Also: Ocean, Atmosphere, Ground
-
product
Charge Coupled Device (CCD) Image Sensors for Space and Ground-Based Astronomy
(CCDs) for Space science, Ground-based Astronomy, and Earth observation applications with an impressive record of successful deliveries to a wide range of customers over 40 years.All Teledyne e2v devices can be supplied partially or fully customised to fit the application and achieve the best possible system performance. CCD image sensor design, manufacture, test and characterisation are carried out in-house enabling control from start to finish. Multi-polysilicon, multi-metal and back-illumination options are available for high resolution, high sensitivity and very low noise.
-
product
Safety Analyzer
SA-2000
The BC Biomedical SA2000 Features: AAMI Load Earth / Ground Lead Resistance Earth/Ground Leakage Current Chassis Leakage True RMS Measurements 85 to 265 VAC Operation.
-
product
Earth Leakage Relays
Variable Earth Leakage Relays in compact 35mm din rail mounting cases for use on 3 phase electrical systems.
-
product
Earth Meter
EM-4055
The EM-4055 Earth Meter is a digital, microprocessor-controlled instrument that allows to measure the earth resistance and ground resistivity (using Wenner´s method), as well as to detect parasitic voltages present in the ground. This instrument is well suitable to measure earth systems in power substations, industries, distribution networks, etc., according to VDE 0413. It is also suitable for soil resistivity measurements, in order to optimize the earth systems project
-
product
Earth Leakage Breaker And Residual Current Device
IGR Series
IGR Leakage Current Analyzer is invented as the world first, and also can measure Insulation Resistance (MO) without power cut-off. This patented instrument can analyze leakage current, and display Igr(resistive), Igc(capacitive), and Io(vector sum), Ground Insulation Resistance, and the phase angle between voltage and current. (IGR ELB) - Operates due to Igr. - Properly-operating in spite of IGC in digital era. ( Not tripping on UPS load and Harmonics and noise area) - Possible to go down Igr for safety of people and animals. - Possible to manufacture high sensitive ELB. - Possible to prevent fire from electric leakage current.
-
product
Ground Network Earth Resistance Tester
HTDW-5A / 736
Wuhan Huatian Electric Power Automation Co., Ltd.
It is suitable for the test of grounding resistance of large power grid in power departments, substations and other institutions.
-
product
Digital ELCB (RCD) Tester
1813 EL
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● Suitable for domestic version.● Better than 3% accuracy (current).● Menu-driven.● Accurate digital readout of disconnection time.● Accurate digital readout of disconnection sensitivity.● Automatic data hold function.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● 60Hz available.
-
product
Partial Discharge Detecting Detectors
Hangzhou Xihu Electronic Institute
Including pulse current PD detecto, high frequency PD detector, transient earth PD detector, ultra high frequency PD detector, and ultrasonic PD detector.
-
product
NI-9435, ±5 VDC to ±250 VDC/10 VAC to 250 VAC, 4-Channel (Sinking/Sourcing Input), 3 ms C Series Digital Module
779010-01
±5 VDC to ±250 VDC/10 VAC to 250 VAC, 4-Channel (Sinking/Sourcing Input), 3 ms C Series Digital Module - The NI‑9435 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel accepts signals from ±5 VDC to ±250 VDC and 10 VAC to 250 VAC; features transient overvoltage protection between the input channels and earth ground; and has an LED that indicates the status. The NI‑9435 is a correlated digital module, so it can perform correlated operations, triggering, and synchronization when installed in a CompactDAQ chassis.
-
product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
785189-01
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Ground Fault Protection Monitors
The Earth Fault Resistance Monitor (EFREM) and the Rotor Health Monitor (RHM) provide wireless rotor ground fault and temperature monitoring for generators and motors. The systems replace older slip ring contact ground fault detectors on any synchronous generator or motor.
-
product
180V-260V AC Socket Tester With RCD Test (For UK)
1943
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*Test for 180~260VAC circuit.*LED indicators & Digital display.*30mA leakage current measurement.*RCD Test.I*t can perform self test after plug-in ( Voltage sould be above 180V ).*Detect faulty wiring status in 3 wire receptacle.*This socket tester will give LED indication as well if the main voltage is below 200V or above 260V.*Earth loop impedance test.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 11W*Frequency: 50Hz
-
product
Satellite Phone Interception Solutions
Satellite Phone (GMPCS-Global Mobile Personal Communications by Satellite) is a terminal device act like a normal mobile. Satellite phones connect to satellites orbiting around the earth. Satellite phones rely on a network of satellites that are either fixed above the Equator (Geostationary) or in Low Earth Orbit (LEO) anywhere from 500 to 1,000 miles above the earth. Satellite phones are rarely affected by violent storms and depending upon their system architecture they can work virtually anywhere in the world. The satellite phone is the best mode of communication where no cellular coverage exists. The most popular Satellite phones are from Thuraya, iridium, and Inmarsat (IsatPhone, IsatPhone Pro and IsatPhone 2).
-
product
sbRIO-9375, Non-Enclosed, 24 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module
781212-01
Non-Enclosed, 24 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module - The sbRIO‑9375 is a digital I/O interface that works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and other devices. Each digital input line is compatible with 24 V logic levels, and all the output lines are compatible with 6 V to 30 V signals, based on the external power supply. The sbRIO‑9375 offers isolation between the input and output banks from channel‑to‑earth ground. Non-enclosed modules are designed for OEM applications.
-
product
Multifunction Electrical Installations Meter
MPI-520
The MPI-520 multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520 is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.Wide range of standard accessories enable to perform all necessary measurements and safety test. Highly professional portable multifunction meter with memory of measured parameters.
-
product
Digital RCD Tester
1612 EL
Standard Electric Works Co., Ltd
●Microprocessor-controlled●Extra large LCD (78 × 67mm)●Very low power consumption●50Hz and 60Hz operation●Accurate digital readout of disconnection time●Over temperature protection●Over voltage protection●Fuse protection●Zero crossing circuitry permits testing at 0° or 180°●Auto power off●Backlight function●Wiring polarity indicator●Measures voltage between Line and Earth before testing●Frequency measurement indication
-
product
High Voltage DC Cable Test Systems
We can offer from ±18kVdc to ±30kVdc units which all have automatic earthing for discharging capacitive loads. They are designed to perform tests on installed cables and jointing systems.
-
product
Concurrent Alternative RF & GNSS Signal Simulation
SimAltNav Replay
Non-GNSS sources of RF (radio frequency) are of interest in GPS-degraded or contested signal environments, with interest focused on LEO (low earth orbit) constellations. These systems offer high receiver signal power (relative to GNSS) and a secure & resilient link to augment GNSS.
-
product
Measuring Device for Testing the Effectiveness of Residual Current Protective Devices (RCD) According to DIN EN 61557-6 (VDE 0413-6)
PeakTech Prüf- und Messtechnik GmbH
A residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE).
-
product
Electric Shock Protection Analysis
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel
-
product
Cable Fault Locator System
Kvtester Electronics Technology Co.,Ltd
To test the HV arcing fault of cable, earthing high &low resistance, short circuit and breakage of the cable, poor contact, etc. If equipped with fault locator, it can decide the exact broken position of the cable ,applies to power cable in various type, voltage and communication cable
-
product
40 Channel Single-Ended Multiplexer Module for 34970A/34972A
34908A
Use the Keysight 34908A module for the 34970A/34972A Data Acquisition/Switch Unit for the greatest density in common-low applications, such as battery test, component characterization, and benchtop testing. Each module switches 40 one-wire inputs. All two-wire internal measurements except current are supported. The module low connection is isolated from earth and can float up to 300 V.
-
product
180V-260V AC Socket Tester (For UK)
1941
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*LED indicators & Digital display.*Test for 180-260VAC circuit.I*t can perform self test after plug-in ( Voltage sould be above 180V ).*Detect faulty wiring status in 3 wire receptacle.*This socket tester will give LED indication as well if the main voltage is below 200V or above 260V.*Earth loop impedance test.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 4W*Frequency: 50Hz
-
product
sbRIO-9425, Non-Enclosed, 24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module
783950-01
Non-Enclosed, 24 V, 32-Channel (Sinking Input), 7 µs C Series Digital Module - The sbRIO‑9425 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each digital input line is compatible with 24 V logic levels. The sbRIO‑9425 offers isolation between the input and output banks from channel‑to‑earth ground. Non-enclosed modules are designed for OEM applications.
-
product
Earth Ground Resistance Meter
1623-2
The Fluke 1623-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1623-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps.
-
product
Global Positioning System Sensors
GPS
GPS sensors are receivers with antennas that use a satellite-based navigation system with a network of 24 satellites in orbit around the earth to provide position, velocity, and timing information.
-
product
DC Earth Leakage Current Measurement
DCZCT-11M
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC Earth Leakage Current Measurement *Bipolar DC ±12V Power Supply*Output DC ±1.5V at DC 10mA *Isolated Housing Case based on UL94V-0*Through Hole PCB Mount Type, Exciting Current Method
-
product
Protective Bonding Testers
RMO-E Series
The RMO-E instruments are designed and ideal for testing protective bonding (grounding) of equipment following the standard IEC 61010-1. Also, they can measure the resistance of high, middle and low voltage circuit breakers, high-current bus bar joints, cable splices, and welding joints. The instruments accurately measure not only in factory environments but also in high-induction fields and substations.Both models generate a true DC ripple-free (less than 1 %) current with automatically regulated test ramps. During a test, the protective bonding testers automatically generate increasing current before measuring and decreasing current after the measurement. Consequently, this significantly decreases magnetic transients and ensures great accuracy.These instruments can store up to 500 measurements in the internal memory and have a built-in thermal printer available as an option.DV Win software communicates with the RMO-E earth resistance meter via USB or RS232 interface. It allows a user to run the test remotely from PC, as well as to download test results, analyze and generate fully configurable test reports.The RMO-E series contains two models, RMO60E and RMO100E. The main difference between these two models is in the maximal test current:60 A DC for RMO60E100 A DC for RMO100E
-
product
Current Protection Relay
The main earth fault protection relays in distributions systems, power stations & large manufacturing / processing plants can fail to detect a high impedance break down to earth causing hazard to human life & potential damage to plant & equipment. In these & other situations demanding extra sensitive earth fault protection, using solid state techniques, can be applied to detect earth currents down to 0.5% of the CT nominal current.
-
product
NI-9266, 8-Channel C Series Current Output Module
785047-02
8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.





























