Cross Correlator
-
product
Auto-Correlator/Cross-Correlator
FR-103WS
The FR-103WS is a dispersion-free Autocorrelator/Crosscorrelator for monitoring the temporal width of ultrashort optical pulses. While providing excellent sensitivity and resolution, the FR-103WS is ideally suited for the measurement of long pulsewidths (up to 200ps).
-
product
Cross-Correlator Pulse Profiling Systems
Rincon
The third order cross-correlator is ideal for looking at the full range of output from amplified femtosecond laser systems. High temporal resolution over a long (close to 1 ns) window shows pulse features that are usually missed, giving the user a detailed and complete picture of the quality and stability of the output pulse parameters of their femtosecond lasersystem.
-
product
Rapid Scanning Auto-Correlator / Cross-Correlator
FR-103XL
The FR-103XL is a dispersion-free Autocorrelator/CrossCorrelator for monitoring the temporal width of ultrashort optical pulses. Offering unsurpassed sensitivity and resolution, it is compact and easy to operate. The FR-103XL is ideally suited for the measurement weak signals in optical telecommunications, as well as pulses from other mode-locked lasers such as Ti-Sapphire.
-
product
Single Shot Third-order Cross- Correlator
Rincon SS
Specifically developed for measuring a wide array of output parameters from ultrafast laser systems including: contrast ratio of laser pulses, determining pulse pedestal, pre- and post-pulses, and amplified spontaneous emission in femtosecond systems.
-
product
Phase Noise Analyzer
NXA-6
This new NXA-6 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 6 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range.
-
product
STEREO PERFORMANCE METER
SPM-1
The SPM-1 measures the stereo content present in any left and right audio program material. It measures 0-50 dB separation on live program material by cross correlating the right and left base-band audio information.
-
product
Phase Noise Analyzer
NXA-50
This new NXA-50 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 50 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range.
-
product
Phase Noise Analyzer
NXA-26
This new NXA-26 is a sea-change in Phase Noise Test Systems. Making both residual and absolute noise measurements out to 26.5 GHz, this self-contained instrument uses either internal or external references with cross correlation for maximum dynamic range. The NXA-26 combines over 25 years of Phase Noise Measurement Technology with an easy to navigate user interface. System operation requires minimal training that will have you making measurements in minutes.
-
product
Phase Noise Analyzers
The phase noise analyzer portfolio from Rohde & Schwarz offers an affordable, mid-range solution with high sensitivity and fast measurements as well as high-end ultra-high-sensitivity solutions with advanced measurements modes. Ideal for phase noise analysis and VCO tests, the industry-leading solutions enable two-path phase noise analysis with real-time cross correlation and fast VCO characterization with built-in low-noise DC sources. Additionally, high-end signal and spectrum analysis can be added into a single box.
-
product
Cross Browser Testing
BrowseEmAll
Live Testing, Screenshots, Code Analytics & Selenium Integration On Your Local Machine. Every browser is just one click away. Mobile Simulators. Test for iOS, Blackberry, Windows Phone and Android. Screenshots. Find layout issues with screenshots. Automated Compatibility. See problems directly in your Code. Side by Side Test browsers and mobile devices simultaneously. Test Automation. Run Selenium Tests Out Of The Box.
-
product
Collaborative Correlative Microscopy
nanoGPS navYX
Correlative microscopy is the combination of multiple modalities performed on the same sample. The results produced emphasize the strengths of each modality while offsetting their individual limitations.nanoGPS navYX™ is an open solution which makes SEM-Raman correlative microscopy seamless regardless of the electron and optical microscopes used. Simply stick the Coordinates Transfer System to the sample!
-
product
Correlative Microscopy
Our modular software platforms enable you to acquire, process and analyze images in multiple dimensions and over various timepoints
-
product
Data Record Adaptor and Correlator
Joiner
nTh Network Technologies to Help
Joiner is a data record adaptor and correlator for mobile and core networks management. The ideal partner for big data architectures with data lakes and analytic applications. Distributed as Docker component, it may be orchestrated in line with the network virtualization function concepts.
-
product
Cross Development Tools
68HC11
Cosmic's toolchain for the 68HC11 family is part of a complete and uniform product line incorporating over 20 years of innovative design and development. Cosmic's familiar and easy to use software interface is available for all Freescale microcontrollers to simplify the migration between targets. All Cosmic products include one year of technical support and updates.
-
product
Correlation Analysis
EDM Modal Correlation Analysis allows the user to correlate two modal models; EMA and/or FEA models. Comparing the experimental data with that acquired through finite element analysis helps in validating the test results. Users can import the geometry model and mode shape data from FEA or EMA software.
-
product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
product
Digital Image Correlation (DIC) Measurement System
EduDIC
EduDIC is a complete Digital Image Correlation (DIC) measurement system, designed as a simple and convenient educational training tool for academic courses in experimental solid mechanics. This easy-to-use system allows academic instructors to effectively present the optical measurement technique of DIC for materials testing to the engineers and scientists of tomorrow.
-
product
DIgital 3D Image Correlation System
Q-400
The Digital 3D Image Correlation System Q-400 is an optical measuring device for true full-field, non-contact, three-dimensional measurement of shape, displacements and strains on components and structures made from almost any material.The Q-400 system is used for determination of three-dimensional material properties in tensile, torsion, bending or combined tests. In addition, deformation and strain analysis can be applied to fatigue tests, fracture mechanics, FEA validation, and much more.
-
product
Cross Flow Cell
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
product
Cross Development Tools
68HC12 and HCS12
Cosmic's toolchain for the 68HC12/HCS12 family is part of a complete and uniform product line incorporating over 20 years of innovative design and development. Cosmic's familiar and easy to use software interface is available for all Freescale microcontrollers to simplify the migration between targets. All Cosmic products include one year of technical support and updates.
-
product
Crossed Roller Tables (Aluminum & Steel)
Del-Tron’s crossed roller tables are known for their high accuracy and exceptional load carrying capabilities. Our crossed roller bearings are available in both aluminum and steel, and the perfect choice for applications where these criteria must be met. Accuracies range from 0.0001” per inch of travel straight line accuracy on our aluminum tables to 0.00008” of parallelism on our steel crossed roller tables and are capable of carrying loads in excess of 2600 lbs.
-
product
Cross Hole Energizer P/S
CHE
Specially designed for small-scale cross-hole surveys, this compact hammer can be used to generate both P and S waves.The hammer can be downloaded using the steel cable and clamped to the requested depth by a pneumatic clamping system manually controlled by a lever from the surface; simply pushing up the steel cable to execute the first shot, the trigger installed on the energizer will start the acquisition for the “P/S”. After that you will have to drop the mass to make the acquisition with inverse polarity.
-
product
High-Speed Digital Image Correlation System
Q-450
The 3D High-Speed Image Correlation System Q-450 allows the full-field, non-contact and three-dimensional dynamic measurement of shape, displacements and strains on components and structures made from almost any material. Based on the digital image correlation technique, the Q-450 system is designed for full-field vibration analysis and high speed transient events. This makes it ideal for ballistics testing, fracture mechanics, shock excitations, the Hopkinson Bar test, or Impact Testing.
-
product
Crossing Control Bypass Switch
XCBS-DL
The XCBS-DL is permanently wired into each crossing warning system, and can be configured with either a removable or non-removable bypass key. Simply connect the track connection harness to the designated track connection terminals. To prevent unnecessary operation of the crossing warning system, insert the key and select "bypass", rotate the knife switch to "bypass" and the crossing is disabled. When in the "bypass" position, a Dummy Track Load is connected to the track wire connections in parallel with the rails and the crossing approaches are shorted, preventing unnecessary activation when track equipment is working in the crossing approach circuit. The opening of one track lead may be desired to prevent unnecessary activation with intermittent shunting on the crossing approaches close to the crossing.
-
product
Gas Filter Correlation Carbon Dioxide Analyzer
Model T360
The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
product
Gas Filter Correlation CO Analyzer
Model N300
Teledyne Advanced Pollution Instrumentation
The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
product
Cross Hatch Cutter
107
The Elcometer 107 Cross Hatch Cutter for adhesion tests provides an instant assessment of the quality of the bond to the substrate.
-
product
Mid-Range Gas Filter Correlation CO Analyzer
Model T300M
Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.
-
product
Cross Domain Security Solutions
Stratign’s Cross Domain Security Solutions are highly trusted, government-accredited network security components that control and, if necessary, block the flow of data between two security domains at all layers.
-
product
Ultra-Low Range Gas Filter Correlation Carbon Monoxide Analyzer
Model T300U
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300U comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.