Signal Conditioning
The processing of signals to reduce noise level, amplify, attenuate, or otherwise condition.
See Also: Signal, Signal Sources, Signal Processing, Signal Integrity, Signal Proccessing, Signal Analyzers, Signaling, Signal Generators, Signal Meters, Signal Conditioners
-
Product
Long Gauge Length Axial Extensometers
Model 3542L
-
Jinan Testing Equipment IE Corporation
The dual flexure design makes the 3542L very rugged and insensitive to vibrations. These extensometers are designed for testing a wide range of materials including metals, plastics, composites and ceramics. Epsilon’s Model 3543 is recommended for applications requiring long gauge lengths and larger measuring ranges.The Model 3542L comes standard with Epsilon’s quick attach kit, making it easy to mount the extensometer on the test specimen. The quick attach kit can be removed, allowing mounting of the extensometer with springs or rubber bands.The 3542L extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
NI-9234, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module
779680-03
Sound and Vibration
4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module - The NI‑9234 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9234 is also compatible with smart TEDS sensors. The NI‑9234 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
96 Channel DPST Relay And Control PXI Carrier Card
GX6196
Relay
The GX6196 is a 6U PXI switch and control board that can be used to create custom switching, signal conditioning, or specific UUT control interfaces. The board provides 96, 2 pole, form A relays, 8 digital I/O lines, and a serial digital interface. All of these resources are available via (5) inter-board connectors which interface to the user defined daughter / mezzanine board. The mezzanine board provides all connections to the unit under test (UUT) via two 78 pin D-sub connectors. The GX6196 is supplied with a front panel which accepts (2) 78 pin D-sub connectors.
-
Product
In-Line IR Sensor
ILA
-
10:1 Distance to Target Ratio, 32 to 932F. Dwyer Series ILA Non-Contact Sensors, measure temperatures from 32 to 932F (0 to 500C) and provide a linear 4 to 20 mA, 0 to 5 VDC or thermocouple output. The 2-wire signal is compatible with almost any indicator, controller, recorder, data logger, etc., without the need for special interfacing or signal conditioning.
-
Product
Dual-Axis Accelerometer For HS5 & 6 Handyscopes, +/- 2G
TP-ACC20-09
-
The Accelerometer is a low cost, low power, complete dual-axis accelerometer with signal conditioned voltage outputs. The output signals are analog voltage proportional to acceleration. The Accelerometer is capable of measuring both positive and negative accelerations to at least +/- 2G.
-
Product
PXIe-4499, 204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module
781370-01
Analog Input Module
204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module - The PXIe‑4499 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4499 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4499 delivers simultaneous sample on all channels. In addition, the PXIe‑4499 includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
Product
Multipurpose Mobile PXI DAQ System
System
The mobile DAQ system achieves seamless integration among signal conditioning, data acquisition, and synchronization that benchtop instruments would not have achieved. By choosing this system over using benchtop instruments, United Technologies Research Center saved hundreds of thousands of dollars.
-
Product
USB to RS-422/RS-485 Converter
ND-6530
Data Acquisition Module
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
Product
Axial Extensometer
Model 3542
-
Jinan Testing Equipment IE Corporation
These extensometers are designed for testing a wide range of materials, including metals, plastics, composites and ceramics. All will work in both tension and compression. The dual flexure design makes them very rugged and insensitive to vibrations, which permits higher frequency operation.They come standard with Epsilon’s quick attach kit, making it possible to mount the extensometer on the test specimen quickly and easily with one hand. The quick attach kit can be removed, allowing mounting of the extensometer with springs or rubber bands.The Model 3542 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.For gauge lengths 100 mm (4 inches) or greater see Model 3542L.
-
Product
IOLITEd
-
IOLITEd - Industrial Data Acquisition SystemStandalone, distributed, and cost-effective data acquisition device with high-end signal conditioning for monitoring and industrial applications. Free software included.
-
Product
Signal Conditioning
-
To get most out of high-quality sensors, accurate, low-noise processing of the sensor signals that are emitted is essential. Kistler offers an attractive portfolio of solutions for signal processing and subsequent data digitization. Piezoelectric (PE) sensors with a charge output require a so-called charge amplifier. On the other hand, piezoelectric sensors with integrated electronics (IEPE) are supplied by Piezotron couplers which decouple and amplify the signal.
-
Product
RTM Communication Board
MS 3636I
-
CPCI Rear IO Communication Board is a signal conditioning and interface board for CPCI Integrated Communication Card (MS3635i). This board has required signal conditioning and interface circuits for RS422. Two 96 Pin Euro Connectors are used to interface all IO’s.
-
Product
3-CH RTD Input Module
ND-6013
Data Acquisition Module
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
Product
Termination Cards
-
A signal conditioning board that provides eight independent SPDT relays, eight isolated outputs, and eight isolated inputs for applications requiring medium current capacity plus I/O isolation between an embedded computer and monitoring/control points.
-
Product
Titan Data Acquisition
DAQ
-
Titan Data Acquisition (DAQ) Systems offer universal signal conditioning, low power consumption, convenient SD card storage, and easy-to-use software. Systems can be purchased as a complete test kit, including custom cables and accessories. Titan products are designed and built in the US.
-
Product
IEPE Signal Conditioning Amplifiers
-
Although IEPE (Integrated Electronics Piezoelectric) sensors is not a new technology there are a wide variety of applications where the measurement instrumentation is not configured with IEPE signal conditioning built in. In these situations it is necessary for the IEPE supply to be provided by an external source. Usually this type of instrument will also provide th user with the option to add gain to the signal being conditioned. The Kemo range of IEPE signal conditioning instruments can be used as stand alone conditioners/amplifiers are many of them can also be integrated with filters.
-
Product
Pressure Sensors
ESCP-SAPT Transmitter
-
ESCP-SAPT pressure transmitters consist of a MEMS capacitive pressure sensor die, which is underpinned by ES’ innovative microfabrication process that has been proven suitable for the mechanical, radiation and temperature environment of space applications. The full custom, radiation-hardened signal conditioning IC was designed entirely by ES, utilizing a standard deep submicron CMOS process of a European foundry.
-
Product
USB DAQ
-
ADLINK USB DAQ modules leverage the expertise of ADLINK's analog design capability, enhancing convenience of data acquisition. Simply plug the ADLINK USB DAQ into a USB port on your computer or notebook for performance equaling or even exceeding that of ADLINK PCI/PCIe DAQ cards, with no need to power down or open the chassis. As well as providing basic voltage measurement, ADLINK USB DAQ modules feature built-in signal conditioning to directly receive measurement from most commonly used sensors, with no need for extra signal processing. From basic testing to high-accuracy measurement, from portable application to industrial automation, the ADLINK USB DAQ series delivers easy, efficient, and accurate measurement every time.
-
Product
Wireless Measurement System for ETSI & FCC Devices for ISM Bands
TS8997
-
The R&S®OSP-B157W8 PLUS 7.5 GHz module with up to eight channels is the core of the system and uses a printed RF switch board in solid-state relay (SSR) architecture. It allows flexible operation of the connected DUT (up to eight ports) for power measurements, signal conditioning via the integrated attenuators, couplers and combiners, RF switching to the measuring instruments in combination with the R&S®OSP-B157WX up to 40 GHz and is controlled by R&S®WMS32 software.
-
Product
USB Signal Conditioning Products
-
Signal conditioning can include amplification, filtering, converting, range matching, isolation and any other processes required to make sensor output suitable for processing after conditioning. It is primarily utilized for data acquisition, in which sensor signals must be normalized and filtered to levels suitable for analog-to-digital conversion so they can be read by computerized devices.
-
Product
High Temperature Diametral Extensometers (1000 C)
Model 3580
-
Jinan Testing Equipment IE Corporation
This model is for diametral strain measurement with furnace and induction heating systems. Quartz rods and water-cooling allow the unit to be used for high temperature testing of metals, ceramics and composites. With induction heating, this model often can be used without water-cooling. When used in furnaces, the extensometer is often mounted directly to the furnace side cut-out. Optional load frame mounting brackets are available for supporting the extensometer in cases where furnace mounting is not possible. These optional mounts are used with induction heating or furnace systems. The Model 3580 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
8-Channel BNC Break-out Card
ProDAQ 5824
-
The ProDAQ 5824 Signal Conditioning Cards are designed to facilitate the interface of the ProDAQ 3424 8-Ch. 24-bit Sigma-Delta ADC Function Cards to a number of sensor types. It does this by providing 8 BNC connectors on the input and a 3424 pin-compatible 50-pin SCSI on the rear of the card.
-
Product
PXIe-4331, 102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module
781345-01
Strain/Bridge Input Module
102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4331 is a high-speed input module that provides integrated data acquisition and signal conditioning for dynamic strain, load, and pressure measurements. This module includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4331 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4331 provides remote sensing, internal bridge completion, and shunt calibration options per channel.
-
Product
Interface Panel for SLSC
THROUGHPOINT™
Interface
Bloomy's ThroughPoint™ Interface Panel provides a simple, yet highly-flexible connection between the unit under test and resources in a National Instruments Switch/Load/Signal Conditioning (SLSC)-based test system.
-
Product
Non-Contact Displacement Meter
-
The principle of the eddy current is applied to measure the distance without contacting an object. This measuring method is widely used in the industry for detecting abnormal vibrations of rotating shafts or ironwork in a production in line. The highly accurate signal conditioning for providing the analog voltage being linearly proportional to displacement can be made easy.
-
Product
Interface ICs
-
Easy to use, flexible, and reliable. Allegro’s sensor interface ICs offer accurate and fast output for signal conditioning in a wide range of applications, from electric vehicle HVAC systems to transmission oil pressure. Our innovative algorithms deliver robust EMC performance and provide critical diagnosticsthat support automotive safety.
-
Product
PXIe-4497, 204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module
781369-01
Analog Input Module
204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module - The PXIe‑4497 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4497 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4497 delivers simultaneous sample on all channels. In addition, the module includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gain, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
Product
Trace-Level Chemiluminescence NO/NO2/NOx Analyzer
Model T200U
-
Teledyne Advanced Pollution Instrumentation
The Model T200U Trace-level NO/NO2/NOx analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is designed to allow ultra-sensitive measurements with a lower detectable limit of 50 ppt while still meeting the requirements for use as a US EPA compliance analyzer.The Model T200U combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer.
-
Product
8AI Modbus RS-485 Remote I/O
ND-6117
Data Acquisition Module
The NuDAM modules provide direct communications with a wide variety of sensors; perform signal conditioning, scaling, linearization and conversion; can acquire measurements of temperature, pressure, flow, voltage, current; and handle multiple digital signal types broadly used in IoT and other industrial applications, such as facility monitoring, environment monitoring, and industrial process control. The new ND-6117, ND-6124, ND-6150, and ND-6160 modules feature Modbus/RTU as the best remote data transmission protocol, which provides customers a comprehensive product offering.
-
Product
Auto Calibration for Load & Extensiometer
-
Jinan Testing Equipment IE Corporation
TE electronic calibration module provides an easy way to calibrate load cell or extensometer and signal conditioning electronics without using a mechanical calibrator. It enables performing on-site electrical calibration and easy to periodically “spot check”, which will help ensure that the load cell and the extensometer and electronics are calibrated correctly.