product
USB-6255, 80 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device
779959-04
80 AI (16-Bit, 1.25 MS/s), 2 AO (2.86 MS/s), 24 DIO USB Multifunction I/O Device - The USB‑6255 offers analog I/O, digital I/O, two 32-bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
8DI/8DO Modbus RTU Remote I/O
ND-6150
The NuDAM modules provide direct communications with a wide variety of sensors; perform signal conditioning, scaling, linearization and conversion; can acquire measurements of temperature, pressure, flow, voltage, current; and handle multiple digital signal types broadly used in IoT and other industrial applications, such as facility monitoring, environment monitoring, and industrial process control. The new ND-6117, ND-6124, ND-6150, and ND-6160 modules feature Modbus/RTU as the best remote data transmission protocol, which provides customers a comprehensive product offering.
-
product
JTAG Boundary-Scan Controller for PXI and PXI-Express 'Hybrid' Slots or Plug-In Controller for PXI-Express Peripheral Slot
JT 37x7/PXI
High speed and performance JTAG Boundary-scan controller for PXI and PXI-Express ‘hybrid’ slots or plug-in controller for PXI-Express peripheral slot.The controllers are targeted at demanding manufacturing test applications, fast in-system flash memory programming and programmable logic configuration. The JT 37×7 is available in different operating levels (memory options) to suit your specific environment and application. Each unit is supplied with a four TAP port signal conditioning module the JT 2147 ‘QuadPOD‘
-
product
PXI-6281, 16 AI (18-Bit, 625 kS/s), 2 AO, 24 DIO, PXI Hybrid, Multifunction I/O Module
779121-01
16 AI (18-Bit, 625 kS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module—The PXI‑6281 offers analog input, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
NI-9234, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module
779680-03
4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module - The NI‑9234 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9234 is also compatible with smart TEDS sensors. The NI‑9234 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
(ITA), Breakout Box & Fixtures
WinSoft provides a wide range of Interface Test Adapters (ITA) and test fixtures to meet the most challenging functional test and signal conditioning requirements. This includes high frequencies, voltages and current.
-
product
sbRIO-9237, Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
781209-01
Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The sbRIO‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the sbRIO‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools. Non-enclosed modules are designed for OEM applications.
-
product
RF Signal Generators
RF Signal Conditioning provides signal manipulation capabilities for high-frequency or broadband signals. You can use these products to augment the capabilities of connected instruments to improve attributes like accuracy and frequency range.
-
product
Multi-Channel Attenuation Control Unit (4-channels), DC to 18 GHz, 0 to 121 dB, 1 dB Step
J7204B
The J7204B is a multi-channel (4-channels) attenuation solution for signal attenuation and conditioning of up to 4 devices under test (DUT). Operating frequency from DC to 18 GHz, with 121 dB, 1 dB steps. Exceptional 0.03 dB insertion loss repeatability per section for the entire 5 million cycles and excellent attenuation accuracy and flatness, the J7204B reduces cost of ownership and provide the best measurement accuracy.
-
product
2- to 8-Channel Anti-Alias Low-Pass Filter and Instrumentation Amplifier Card
AAF-3
The AAF-3 is a 2- to 8-channel anti-alias low-pass filter and instrumentation amplifier ISA bus plug-in board for front-end signal conditioning in PC-based data acquisition systems.
-
product
SIGnal Workbench
Flexible, programmable signal conditioning and fault insertion solutions for data acquisition applications.
-
product
Accelerometers
Analog Devices accelerometers and iSensor® MEMS accelerometer subsystems provide accurate detection while measuring acceleration, tilt, shock, and vibration in performance driven application. Our portfolio leads the industry in power, noise, bandwidth, and temperature specifications, and offers a range of MEMS sensor and signal conditioning integration on chip. Our MEMS-based Circuits from the Lab® reference designs have been built and tested by ADI experts to help you jumpstart your next system design.
-
product
Data Acquisition and Control System
DAQ 7000
data acquisition and control system that provides connectivity, signal conditioning and modular I/O for variety of sensors or signals, and it is an ideal DAQ for field deployment.
-
product
PXI-6289, 32 AI (18-Bit, 625 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module
779123-01
32 AI (18-Bit, 625 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module—The PXI‑6289 offers analog I/O, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
NI-9232, 3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
782000-01
3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9232 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9232 is also compatible with smart TEDS sensors. The NI‑9232 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
780264-02
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
product
PCI-6221, 16 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO PCI Multifunction I/O Device
779418-01
16 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO PCI Multifunction I/O Device - The PCI-6221 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
product
Dual-Axis Accelerometer For HS3/4/4-DIFF Handyscopes, +/- 5G
TP-ACC50-25
The Accelerometer is a low cost, low power, complete dual-axis accelerometer with signal conditioned voltage outputs. The output signals are analog voltage proportional to acceleration. The Accelerometer is capable of measuring both positive and negative accelerations to at least �+/- 5G.
-
product
Digital/Analog/Frequency Measurement Module
JT 2149/DAF
The JT 2149/DAF is a compact, mixed-signal (Digital/Analog/Frequency) measurement module for use in JTAG Technologies’ widely-used JT 2147 (QuadPod) signal conditioning interface. The DAF module has been designed to replace a regular TAP Pod and provides 28 measurement channels plus a clock generator. When connected to a circuit board via edge connector or test fixture/jig test pins, the module enhances standard digital boundary-scan tests by enabling a series of analog and frequency measurements to be made.
-
product
Operational Amplifiers
Op Amps
Operational amplifiers, known also as op amps, play a major role in analog signal conditioning applications. Invented by Karl Dale Swartzel Jr. in 1941, these products are largely used in today’s electronic devices.
-
product
NI-9250, 2-Channel, 102.4 kS/s/ch Simultaneous, ±5 V, C Series Sound and Vibration Input Module
783827-01
2-Channel, 102.4 kS/s/ch Simultaneous, ±5 V, C Series Sound and Vibration Input Module - The NI‑9250 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers and microphones. The NI‑9250 is also compatible with smart TEDS sensors. The NI‑9250 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
Instrumentation Calibration Services
We offer a range of instrumentation calibration services for Kemo products in addition to other signal conditioning and sensors. We have many decades of experience in the manufacture, test and calibration of our instruments and those of our competitors. Please refer to the list below for an example of our calibration options, all equipment used within our calibration department is calibrated and traceable to a UKAS accredited National standard:
-
product
DAQ-Embedded Computers
MIC-1800 series units are standalone embedded computers with integrated data acquisition modules and signal conditioning.
-
product
IOLITEd
IOLITEd - Industrial Data Acquisition SystemStandalone, distributed, and cost-effective data acquisition device with high-end signal conditioning for monitoring and industrial applications. Free software included.
-
product
18 GHz Up/Down Converter & Signal Conditioning
SC2250
The SC2250 extends the useful range of traditional 6GHz RF instruments for operation at microwave frequencies up to 18GHz. It provides excellent integration capability with other modular products such as National Instrument’s Vector Signal Transceiver (VST). Selectable filtering is provided for signal conditioning applications requiring spurious and harmonic rejection.
-
product
Extensometers for Indirect Tensile Testing of Asphalt
Model 3911
Jinan Testing Equipment IE Corporation
For indirect tensile testing, such as for resilient modulus, these extensometers measure the lateral deformation of specimens. They are self-supporting on the sample and clip on in seconds. The traditional way this deformation has been measured was prone to errors caused by slight rocking of the sample as it is loaded. The self-supporting design of the Model 3911 eliminates this problem. This unit will handle the dynamic pulse requirements of resilient modulus testing.The speed of mounting makes test set-up much faster than with the older method. The pivot mounting used ensures that the specimen contact pads meet the often uneven asphalt surface as well as possible. The measuring range options available allow a wide range of testing, yet can easily measure the sometimes very small displacements required.The Model 3911 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
3-Slot Data Acquisition Mainframe With GPIB, Two 20-Channel Switch Modules, And One 20-Channel Multiplexer Module
DAQ973SB
The DAQ973SB Better Multiplexer Bundle offer includes a DAQ973A three-slot data acquisition mainframe, two 20-channel DAQM903A Actuator / GP switch modules, and one 20-channel DAQM901A multiplexer module. This bundle provides the following:3-slot mainframe with USB, LAN, and GPIB6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2- and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junction20-channel actuator / general-purpose switch with independent single-pole, double-throw (SPDT) relaysbuilt-in signal conditioning to measure thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance
-
product
Data Acquisition Devices
Our data acquisition and encoding systems provide significant performance in reception, signal conditioning and encoding of all types of signals while used in missiles, airborne vehicles, mobile ground-based testing and other platforms that require ease of operation, flexibility, ruggedization and small packaging.
-
product
Frequency to Current Converter
DAT4540R
The Frequency to Current converter DAT4540R is a signal conditioning din rail mount converter which converts a pulse input to an analog output equal to the set range which is selectable from 0.1 Hz up to 20 KHz. The DAT4540R also provides 2 relay outputs and a transistor output. The input can be from a Tacho, TTL, PNP transistor or from any Namur standard. The DAT4540R provides a Voltage or Current output that is isolated from the power supply and input.
-
product
Dual-Axis Accelerometer For HS3/4/4-DIFF Handyscopes, +/- 16G
TP-ACC160-25
The Accelerometer is a low cost, low power, complete dual-axis accelerometer with signal conditioned voltage outputs. The output signals are analog voltage proportional to acceleration. The Accelerometer is capable of measuring both positive and negative accelerations to at least +/- 16G.