Calibration Standards
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Software, Calibration Services, Calibration References
-
product
Data-based Modeling and Calibration
ASCMO
ETAS ASCMO is the easy-to-use-solution for advanced model-based calibration and data-based modeling in significantly less time. ETAS ASCMO enables the fast and efficient development of accurate data-based models. Once created, these high-accuracy models can be used to optimize parameters of real systems such as engine ECUs or plant models in different simulation environments (e.g. Simulink or HiL-Systems). Both, steady state and dynamic/transient system behaviors can be captured.
-
product
Standard 0.30 (8.50) - 1.06 (30.00) Battery Probe
BIP-3
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 60Recommended Travel (mm): 1.52Mechanical Life (no of cyles): 250,000Overall Length (mil): 511Overall Length (mm): 12.98
-
product
Standard Gain Horns
Standard gain horns can be used to experimentally determine the gain of other antennas by using the substitution method. The standard gain horn and the antenna under test are alternately connected to a well matched detector system in order to compare their relative power levels. The power level difference is then added to the appropriate level of the calibration curve to determine the absolute gain of the antenna under test.View more Standard Gain Horn Antennas
-
product
Probes, Sensors, Measurement Microphones, Calibrators, Accessories
Passive Probes, Active Probes, USB Isolators, Noise & Vibration Sensors & Accessories, Electro-Acoustic Test Accessories
-
product
Resistance Standards
Ohm-Labs manufactures reference grade resistance standards from 10 micro-ohms to 10 teraohms. Each range of standards utilizes the latest advances in materials and processing for high stability and immunity from changes in ambient environment. All products are supplied with ISO17025 accredited calibration.
-
product
Lens Calibration
SpyderLENSCAL
A fast, reliable method of measuring and adjusting the focus performance on your camera and lens combinations.
-
product
Zero Gas Generator - Calibration of Ambient Air Monitoring Systems
ZNV-7
HORIBA Europe’s Zero Gas Generator ZNV-7 has been developed to check the zero point and dilute the span gas sources in order to carry out the calibration of ambient air monitoring systems. The increasing sensitivity of ambient air analyzers is required by strict official guidelines, which demands pure and dry air in a sufficient quantity at constant pressure.
-
product
Multiple High Resistance Standard
MHS
*1 MEGOHM TO 1 TERAOHM*FULLY GUARDED*HIGH IMMUNITY FROM AMBIENT TEMPERATURE CHANGES*TRANSPORTABLEOhm-Labs' new Multiple High Resistance Standard maintains state-of-the-art resistance at levels above 1 megohm.
-
product
Nanolattice Standards for Analytical Instruments
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of Electron and Atomic Force Microscopes (AFM). Make the grade, with the highest quality pitch standard of its kind available.
-
product
Decade Box, Calibrated, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL
The 72-7265 CAL from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
product
Automatic Meter Calibration Console
PMT40600
Power Measurement Technologies Inc.
Provides Measurement Canada compliant, fully automated testing of single and polyphase electrical energy and demand meters. Amplifier technology provides stable, low distortion, four-quadrant dynamic loads up to 600VAC and 200 amperes.
-
product
Standard 2.90 (82.20) - 5.40 (153.00) Switch Probe
TSP157-H200-1
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
product
Calibration - Certification - Repair Services
Acculab Measurement Standards, Inc.
Whatever your Test & Measurement Equipment service needs, ACCULAB has a cost-effective solution! From complete calibration, certification and repair capability at our 6200-sq.ft. state-of-the-art laboratory, to the convenience of on-site calibration at your facility, ACCULAB can tailor a program to meet your individual requirements.
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74A
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40J
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
product
Gas Analyzer Calibration
KANE
Partnering with KANE we can now offer you a fast and reliable gas analyser calibration, repair and sales solution. Working closely with KANE we have we can offer you a quick turnaround time usually 6-8 working days or less.
-
product
Standard Normally Open
Is an optically coupled element that combines a GaAs infrared LED on the input side with anormally-open MOS FET on the output side to realize an excellent cost performance.The small, thin package and high sensitivity of this element makes it ideal for battery-driven mobile devices, and its small offset voltage at power-on and good linearity are also make it suitable for controlling micro analog signals.
-
product
Repair & Calibration Service
Repair and calibration facility is one of the nation's premier laboratories that deals exclusively with electronic test and measurement equipment.
-
product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-2V1S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
product
Multifunction Calibrators
To automate and optimise the calibration process Time Electronics' EasyCal Calibration Software can be used with compatible multi product calibrators. Increase speed of calibration, consistency of results and produce calibration certificates and reports to ISO 9001, ISO 17025, and other quality standards. With comprehensive features it provides the ideal platform for an efficient calibration program.
-
product
Custom Optical Components and Standards
With the amount of applications that optical components have, no one could hope to have the perfect component for every possible scenario. For this reason, APPLIED IMAGE makes easy the process of designing, building, and delivering custom components to our customers. Our engineering process is designed to produce the best parts in the industry and more importantly, the best component for your specific needs. The APPLIED IMAGE experience will cover the project with expert engineers from start to finish. Use the form below to start the conversation for checkerboard and dot arrays, stage and image analysis micrometers, reticles and machine vision components.
-
product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-1R1S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
product
Automatic Battery with Filters with Standard Contactors
BATLVF800
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation ofpower factor in low voltage instalations
-
product
Standard 1.24 (35.00) - 2.94 (85.00) Battery Probe
CCA-006
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 78Full Travel (mm): 1.98Recommended Travel (mil): 40Recommended Travel (mm): 1.02Overall Length (mil): 669Overall Length (mm): 16.99
-
product
Mass Flow Calibration
Allow instrument interchangeability without affecting your process and meet ISO 9001 requirements easily and efficiently with Process Instruments’ Mass Flow Calibration and Repair Services.
-
product
Standard 1.53 (43.00) - 4.00 (114.00) Bead Probe
BTP-72HC-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Test Workflow Standard
Test Workflow equips engineers with application-specific tools so that they can choose the right one for the job—from graphical programing environments to no-code and interactive software applications. Engineers can use Test Workflow software to perform quick ad-hoc tests, build an automated test system, automate data analysis and reporting, develop test sequences, and more.
-
product
Standard CT
800A
• High accuracy of 800/5A (0.05%) • multiple ratios • Various Current ratings
-
product
Calibration Hand Pumps
Nagman Instruments & Electronics Pvt. Ltd
Calibration hand pumps are the most cost-effective way to calibrate pressure devices. At Nagman, you can find Calibration hand pumps that are the best in the industry. Calibration hand pumps are used to generate pressure. Which can be hydraulic, pneumatic, or vacuum. This kind of pressure generation is done during testing and calibration applications. We also offer calibration pumps that can help in high pressure to low pressure calibrations. Visit Nagman website and browse through the range of calibration hand pumps to find the right device for your calibration needs.
-
product
Standard Magnetizers
The selection of a magnetizing system begins with an analysis of the production requirements, including magnet material, magnet size, magnetizing orientation, number of poles, production speed, magnet measuring, and other operations that are necessary. After careful evaluations of these factors, and reviews of samples and/or drawings, our application engineers can recommend a system that will meet your requirements.