ICP Microphones
measure acoustic frequency, time and noise levels.
-
product
Quartz ICP® Links
Link-style sensors measure dynamic compression and tension. They are constructed using a force ring that is under compressive pre-load between threaded mounting hardware. The threaded mounting on both ends of the sensor supports integrated link-style installations. Versions offering full-scale measurements of 10 lb to 50k lb (45 N to 220k N) compression and 30k lb (130k N) tension are available.
-
product
Probes, Sensors, Measurement Microphones, Calibrators, Accessories
Passive Probes, Active Probes, USB Isolators, Noise & Vibration Sensors & Accessories, Electro-Acoustic Test Accessories
-
product
On-line ICP / ICP-MS Sample Preparation System
SDX ʜᴘʟᴅ
The SDXHPLD system combines the proven ASX‑560 autosampler with a novel vortex mixing dilution accessory. The system dilutes in the same way you do by hand: volume-to-volume dilution, using a highly accurate syringe pump. But it also goes an additional step to vortex mix the resulting dilution prior to sample introduction to ICP and ICP-MS.The SDX employs vortex mixing to promote homogenization of a sample to ensure accurate and precise analysis following dilution. The variety of sample matrices submitted for trace element analysis necessitates the need for mixing. This long overdue capability improves data quality by fully homogenizing a dilution mixture rather than performing in-line combination.The SDXHPLD is a straight-forward, fully-integrated solution for automated dilution of aqueous and acid base sample prep for ICP or ICP-MS.
-
product
Phantom Powered Measurement Microphone System
7052PH
The 7052PH Type 1.5TM phantom powered measurement microphone system offers a cost effective solution to acoustic measurements from phantom powered sources. Type 1.5TM - a superior Type 2. Frequency Response: <3 Hz to > 20kHz typ.(capsule). Sensitivity: 22 mV/Pa (-33 dBV/Pa)typ. Dynamic Range (capsule) 1% THD: <20dBA-150dBSPL (Capsule).
-
product
SparkFun Electret Microphone Breakout
This small breakout board couples an Electret microphone (100Hz--10kHz) with a 60x mic preamplifier to amplify the sounds of voice, claps, door knocks or any sounds loud enough to be picked up by a microcontroller’s analog-to-digital converter. Each breakout comes fully assembled and works from 2.7V up to 5.5V.
-
product
Type 1 Phantom Powered Measurement Microphone
MK224PH
The MK224PH Type 1 phantom powered measurement microphone system offers a cost effective solution to acoustic measurements from phantom powered sources. Frequency Response: +/-2dB (8 Hz to 18kHz). Sensitivity: 50 mV/Pa (-26 dBV/Pa)typ. Dynamic Range 3% THD: 14dBA-145dB.
-
product
PCB Triaxial Accelerometer, 1000mV/g, ICP®(IEPE), 0.5Hz-3kHz
784815-01
The PCB Miniature Triaxial Accelerometer helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB Miniature Triaxial Accelerometer features a sensitivity range of 1000 mV/g and requires the PCB lightweight cable with 4-socket plugs.
-
product
MEMS Microphones
A MEMS microphone is an electro-acoustic transducer housing a sensor (MEMS) and an application-specific integrated circuit (ASIC) in a single package.
-
product
PCB High Sensitivity, 100mV/g, ICP® (IEPE) Accelerometer
784170-01
The PCB HSTA15 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB HSTA15 features a sensitivity range of 10 mV/g and requires a 4-socket plug-to-3 BNC plug cable.
-
product
Ground Isolated ICP® Pressure Sensors For High Frequency
PCB® Series 102B is a ground isolated version of the Series 113B. These sensors have all of the same features and benefits of the 113B Series, plus the added benefit of isolation, which helps prevent ground loop problems. This series can accommodate an optional ablative coating (Prefix: CA) to protect the diaphragm from thermal shock in flash-temperature applications.
-
product
ICP Electret Array Microphone
130A23
Nominal Microphone Diameter: 1/4" Frequency Response Characteristic (at 0 incidence)Free-FieldInherent Noise (A Weighted)<30 dB(A) re 20 Pa<30 dB(A) re 20 Pa Dynamic Range (High)150Environmental Temperature Range ( Temperature Effect on Output (-10 to +50 C)<0.7 dB<0.7 dB[2] Influence of Axial Vibration Excitation Voltage 18 to 30 VDC18 to 30 VDC
-
product
Precision Condenser Microphone
377B11
Performance:Nominal Microphone Diameter:1/2 CharacteristicPressureOpen Circuit Sensitivity: 50 mV/Pa50 mV/PaInherent Noise<15 dB(A) re 20 Pa<15 dB(A) re 20 Pa Dynamic Range (3% Distortion Limit)>143 dB re 20 Pa>143 dB re 20 Pa EnvironmentalTemperature Range (Operating)-40 to +248 F-40 to +120 C Temperature Coefficient of Sensitivity (+14 to +122F (-10 to +50C))0.005 dB/F0.009 dB/C
-
product
Microphone Interfaces
MEMS
Listen offers 2 MEMS digital microphone measurement interfaces from Portland Tool & Die, the laboratory-grade DCC-1448 and the low cost PQC-3048 for production line use.
-
product
USB Controlled Loudspeaker & Microphone Test Interface
AmpConnect™ ISC
AmpConnect ISC is an all-in-one audio interface that simplifies your test setup and operation. It is a single, rugged, rack-mountable piece of hardware containing a high-accuracy audio interface, impedance box, amplifier, headphone amplifier, 2 microphone power supplies and digital I/O. It replaces multiple hardware devices, connecting to your computer via a single USB cable, and it is fully controlled by SoundCheck. This simplifies setup and calibration, eliminates cabling and reduces connectivity errors, as well as reducing overall system cost.
-
product
ICP Plasma System
The AXIC IsoLok® Inductively Coupled Plasma (ICP) Load-Locked Processing System from AXIC, Inc. defines a new concept in Deep Reactive Ion Etch (DRIE) and low temperature-low damage Plasma Enhanced Chemical Vapor Deposition (ICP-PECVD) plasma processing. The system is based on a modular design starting with a universal chamber and cabinet unit with ICP etch or deposition bottom electrodes available for easy installation into the chamber unit combined with a load-lock. We are confident you will find the ease of use, variety of plasma processes, serviceability and attractive pricing unsurpassed by any other plasma product in the market.
-
product
Inductively Coupled Plasma Spectroscopy (ICP-OES/MS), ICP Analysis Services
ICP-OES measures the light emitted at element-specific characteristic wavelengths from thermally excited analyte ions . This light emitted is separated and measured in a spectrometer, yielding an intensity measurement that can be converted to an elemental concentration by comparison with calibration standards. ICP-MS (ICP-Mass Spec) measures the masses of the element ions generated by the high temperature argon plasma. The ions created in the plasma are separated by their mass to charge ratios, enabling the identifcation and quantitation of unknown materials. ICP-MS offers extremely high sensitivity (i.e. low detection limits) for a wide range of elements
-
product
SparkFun Analog MEMS Microphone Breakout
ICS-40180
The SparkFun Analog MEMS Microphone Breakout makes it easy to work with the InvenSense ICS-40180 analog microphone. This board features an OpAmp to bring the output of the microphone to a usable level, allowing you to plug directly into an ADC on a microcontroller or something like the SparkFun Spectrum Shield.
-
product
Microphone System
378B02
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
product
High Temperature ICP® Accelerometers
PCB® offers specially designed and tested ICP® accelerometers for conducting vibration and shock measurements under demanding environmental conditions of up to 356 °F (180 °C). These sensors combine proven quartz and ceramic shear sensing technology with specialized, built-in microelectronic signal conditioning circuitry to achieve dependable operation in extreme temperatures and through repetitive temperature cycling. Laser-welded, hermetically sealed, lightweight titanium or stainless steel housings offer further protection from the environment. Prior to shipment, each sensor undergoes a battery of tests to ensure survivability for its intended use. Such tests include temperature soak at elevated temperatures, temperature cycling, and exposure to highly accelerated screening procedures with hydraulically actuated shakers.
-
product
Microphone Preamplifier
426B03
Performance: Nominal Microphone Diameter:1/4"Frequency Response: (0.1 dB) (re 1 kHz)5 to 126000 Hz5 to 126000 Hz Frequency Response
-
product
ICP-MS spectrometers (ICP MASS)
SPECTRO Analytical Instruments GmbH
SPECTRO MS is a double-focusing sector field ICP MS (ICP mass spectrometer) based on a Mattauch-Herzog geometry with a newly developed ion optic and pioneering detector technology. It is the only ICP MS instrument available on the market today that is capable of simultaneously measuring the complete mass range used for inorganic mass spectrometry from 6Li to 238U with a permanent ion beam going to the detector.
-
product
Precision Condenser Microphone
377C01
Performance:Nominal Microphone Diameter:1/4"Open Circuit Sensitivity 2.0 Open Circuit Sensitivity (3 dB)-54 dB re 1 V/PaFrequency Range Inherent Noise<35 Temperature Coefficient of Sensitivity (+14 to +122FHousing Material: Stainless Alloy
-
product
2 Channel Microphone Power Supply and Conditioning Amplifier
SoundConnect 2 mic power supply
SoundConnect 2 is a rugged 2-channel USB controlled microphone power supply and conditioning amplifier.
-
product
Microphone Calibration Workstation
9350C
The Precision Acoustic Calibration Workstation Model 9350C is an accurate, turnkey, automated PC-based system that features cost-effective calibration of ¼", ½" and 1" microphone cartridges (open-circuit sensitivity), microphone cartridges with preamplifiers (closed-circuit sensitivity) and microphone Frequency Response Function.
-
product
Microphone Preamplifier
426B31
Performance:Nominal Microphone Diameter:1/4" Frequency Response:3.98 to 126000 Hz3.98 to 126000 10.0 to 126000 Hz10.0 to 126000 HzElectrical Noise (A-weight)3.8 TEDS CompliantYes
-
product
For accurate testing of headphones, microphones telephones and loudspeakers
Artificial Mouths, Ears, and Couplers
Listen supplies artificial mouths, ears and ear couplers from Brüel and Kjær, GRAS and more.
-
product
instrumentation microphone
josephson c550h
A precision omnidirectional measurement microphone by Josephson Engineering that is thermally conditioned for stability and manufactured in California. These mics are individually calibrated and matched for sensitivity at the Josephson facility. The nose diameter fits nominal ½” calibrators perfectly. This is an excellent product and a great value for an instrumentation microphone and is supplied with a mounting clip and vinyl pouch.
-
product
ICP® Accelerometers With Excellent Thermal Stability
The single and triaxial ICP® accelerometers are designed with a low temperature coefficient, wide operating temperature range, and good broadband measurement resolution, making them ideal for any vibration measurement requiring tight control of amplitude sensitivity over a wide thermal gradient. To alleviate the effects of high frequency overloads caused by metal-to-metal inputs, a low pass filter has been incorporated in all models, ensuring accurate data in the frequency range of interest.
-
product
complete 1/2 inch Type 1 Measurement Microphone System
PS9200KIT
A complete 1/2 inch Type 1 measurement microphone system. Available in 1 Inch and 1/4 Inch versions. The heart of the KIT is the 1/2 inch Type 1 measurement microphone. A selection of 4 different 1/2 inch capsules is offered. These include models with frequency responses to 40 kHz, noise floors of 12 dBA in both free field and pressure versions. Microphone sensitivities range from 12 to 50 mV/Pa.





























