ICP Microphones
measure acoustic frequency, time and noise levels.
-
product
Reusable ICP® Strain Gauge
This high-resolution dynamic alternative to bond foil strain gauges uses a quartz sensing element in a durable, titanium housing. It has 0.0006 microstrain resolution, 5 volt output, 100k Hz frequency response and 0.5 gram mass for lightweight test articles. The reusable sensor comes with a calibration certificate, attaches to the test specimen in 60 seconds and is removed in 10 seconds.
-
product
XRF, AA & ICP sample preparation
Claisse Range
Designed for unprecedented analytical accuracy and repeatability, Claisse® electric and gas automatic instruments set new benchmarks in fusion capabilities. The same is true for Claisse pre-fused and homogeneous borate fluxes, high-quality platinumware, as well as analytical consulting services.
-
product
Microphones
All these measurement microphones have a XLR connector and require a phantom power. They can be connected to specially equipped soundcards or pre-amplifiers, only.
-
product
Single Channel Microphone Power Supply
SoundConnect Microphone Power Supply
SoundConnect is a cost-effective, single-channel microphone power supply for audio test applications.
-
product
Measurement Microphones
All microphones are omni-directional and 48V phantom powered. The XL2 Analyzer microphones include an electronic data sheet. The Automated Sensor Detection (ASD) of the XL2 automatically reads this data sheet, and recognizes the microphone model, sensitivity and calibration data. This ensures accurate measurement results.
-
product
HEAD artificial head microphones
HSU III
The HEAD-Shoulder-Unit HSU III is an artificial head microphone for binaural recordings.
-
product
Ultrasound Microphone
M500
The M500 microphone is easily used with a Windows PC/tablet/laptop to record bat calls and other ultrasonic signals with the highest quality. For recording with the M500, the BatSound Touch or BatSound Touch Lite software is used.
-
product
High Sensitivity ICP® Accelerometers
High sensitivity ICP® accelerometers are specifically designed to enable the detection of ultra-low-level, low-frequency vibrations associated with very large structures, foundations, and earth tremors. These sensors typically possess exceptional measurement resolution as the result of its comparatively larger size, which furnishes a stronger output signal and a lower noise floor. All units are hermetically sealed in a titanium or stainless steel housing. Models that include a 2-pin, military style connector provide the added benefit of being electrically case isolated for superior RF and EMI protection.
-
product
Microphone Pre-Amp Audio Interfaces
Analog Devices mic pre-amp audio interfaces provide a high fidelity, high performance solution for audio products. Specifications for this family include ultralow 1.5 dB noise figures, 140 dB gain range, and high gain capability. Operating in an extended industrial temperature range of –40°C to +85°C, this portfolio of mic pre-amp audio interfaces supports many applications, including precision instrumentation, active filters, low noise amplifier front ends, surveillance systems, computerized voice recognition, and a variety of other industrial and consumer products. As the first choice for serious audio engineers, Analog Devices mic pre-amp audio interfaces can give your applications the performance needed to meet the most demanding specifications.
-
product
Electret Measurement Microphone
EMM-6
The EMM-6 is a precision electret condenser microphone designed for measurement and critical recording applications. The extremely flat frequency response and true omni-directional polar pattern make it perfect for use with room acoustic analyzers and audio measurement systems. The EMM-6 microphone is individually hand calibrated using a laboratory standard Brüel & Kjær microphone in conjunction with a DAAS computer measuring system. Each microphone includes stand mount, foam windscreen, transport case, and its own unique calibration response graph.
-
product
Multitype ICP Emission Spectrometers
ICPE-9800 Series
Due to their high detection sensitivity down to ppb levels, ability to analyze a broad 5 to 6-digit range of concentrations, and ability to measure multiple elements simultaneously, ICP emission spectrometers are used in a broad range of fields, such as environmental testing, pharmaceuticals, foods, chemicals, and metals. ICPE-9800 Series of simultaneous ICP atomic emission spectrometers are next-generation systems that offer the superior accuracy necessary to simultaneously and quickly analyze multiple elements regardless of their concentration levels. They also feature user-friendly software that makes analysis easy. Furthermore, the systems reduce analysis costs while providing the highest performance levels in the industry. ICPE-9800 Series systems represent the ultimate in ICP atomic emission spectrometry for environmental, pharmaceutical, food, chemical, metal, and other fields.
-
product
23KHZ Measurement Microphone
M23
The M23 is a precision engineered 23kHz omnidirectional measurement microphone ideally suited for acoustical measurements including loudspeaker design and quality control, sound system setup and troubleshooting, room acoustics, or any application where an accurate free-field measurement microphone is required.
-
product
Measurement Condenser Microphone
ECM8000
The ECM8000 is a specialized condenser microphone designed for use with real-time analyzers, such as our ULTRACURVE DEQ2496, to provide an accurate acoustic picture of the room. You can then use your graphic EQ to fine-tune your system's performance to perfectly match the characteristics of any acoustic environment.
-
product
Microphone Calibrators
Trig-Tek™ 402H & 402PSI
Portable, self-contained, high-intensity acoustic microphone calibration source













