Microphones
convert sound pressure to an electrical current.
See Also: Phone, Telephone, Geophones, Headphone, Hydrophones, Measurement Microphones, Mic, Electroacoustic, Headset
-
Product
Passive Wildlife Recorders - Acoustics & Bats
-
Now you can record bats, birds, frogs and other vocalising wildlife with one device. An easy-to-use recorder, compact, lightweight and customisable. It is designed to survive your tough field conditions. It is weatherproof and robust, with low-profile microphones (to reduce the likelihood of pesky livestock and wildlife chewing them).
-
Product
Transducers
-
Is a unit which comprises a preamplifier fed by a constant current ICP and a condenser microphone
-
Product
PXI-4461, 204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module
779687-01
Analog Input Module
204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module—The PXI‑4461 is designed for sound and vibration applications. It provides two-channel dynamic signal generation and two-channel acquisition, and you can use one of six gain settings to configure your input range. The PXI‑4461 also includes software-configurable AC/DC coupling and IEPE conditioning. The PXI‑4461 includes the hardware and software needed to make precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive noise, vibration, and harshness (NVH); and machine condition monitoring.
-
Product
Microphones & Accessories
-
Applied Research and Technolgy
Creative choices for recording, and USB mics for content creators.
-
Product
Digital Automatic Matrix Mixer
DM1624f
-
The DM1624F is a powerful digital audio processing, mixing and routing system. The primary applications are sound reinforcement and conferencing in boardrooms, courtrooms, worship centers, distance learning systems, hotels and other applications with multiple microphones and loudspeakers. The design represents a milestone in DSP technology in its basic architecture and in its processing speed and efficiency.
-
Product
Tone Generator
A15TG
-
The Shure A15TG Tone Generator is a battery-powered 700 Hz signal source used to troubleshoot audio systems by checking microphone lines for correct patching and detecting unusual noise that is present. The output level of the A15TG is approximately 42 dBV.
-
Product
Microphone Preamplifier
426A11
-
1/2-inch ICP preamplifier with gain and filter switches (for prepolarized microphones)ICP(R) low noise preamplifier with gain, filters, and TEDS
-
Product
Signal Conditioners
-
Metra Mess- und Frequenztechnik in Radebeul e.K.
Metra has been manufacturing amplifiers for piezoelectric transducers for over 50 years. We offer economic charge amplifiers and signal conditioners for IEPE transducers including microphones.
-
Product
Class 1 Measuring Instrument
Bedrock SM90
-
The Bedrock SM90 is a versatile class 1/ type 1 acoustic measuring instrument, suitable for a wide variety of applications. With its high-quality 1/2" prepolarized microphone capsule, it is the instrument of choice whenever accurate and reliable acoustic measurements are required.
-
Product
Comprehensive Simulation of Master, Slave and End Nodes in A 2 B ® Networks
Infotainment Test Device ITD 1024
-
The complexity, cost and weight of audio systems are significantly reduced with the Automotive Audio Bus (A 2 B ® ) from Analog Devices Inc. Regardless of their hierarchical structure or use as master or slave, all A 2 B ® products must be adequately tested before use. This applies, for example, to HiFi amplifiers/loudspeakers, head units, eCall systems, microphones, vibration/noise suppression units, actuators or sensors.Our small and very compact infotainment test system ITD 1024 takes on this task for you: It comprehensively and extremely reliably tests all A 2 B ® signals and communication in all phases of the product development process - during development, for validation and in production.
-
Product
Signal Splitter
-
The Dynamic Signal Buffered Splitter protects sound and vibration sensor acquisitions from the unwanted effects of a parallel troubleshooting or diagnostic instruments. G Systems Dynamic Signal Buffered Splitter provides buffered and unbuffered outputs connected to the same signal input. Up to 16 sensors, typically accelerometers, proximity probes, microphones, and pressure transducers, may be connected to the 16 signal inputs.
-
Product
Microphone Preamps
-
Applied Research and Technolgy
Unlock your mic's full potential with advanced features like variable impedance, mid-side processing, and real tube warmth.
-
Product
Surge Voltage Generator
SSG 1500
-
Cable fault location with the BAUR SSG 1500. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit
-
Product
Precision Condenser Microphone
377B11
-
Performance:Nominal Microphone Diameter:1/2 CharacteristicPressureOpen Circuit Sensitivity: 50 mV/Pa50 mV/PaInherent Noise<15 dB(A) re 20 Pa<15 dB(A) re 20 Pa Dynamic Range (3% Distortion Limit)>143 dB re 20 Pa>143 dB re 20 Pa EnvironmentalTemperature Range (Operating)-40 to +248 F-40 to +120 C Temperature Coefficient of Sensitivity (+14 to +122F (-10 to +50C))0.005 dB/F0.009 dB/C
-
Product
Noise Meters
-
Here you will find a full range with an industrial standard noise meter / sound meter to suit every requirement. With the portable noise meter you can carry out measurements quickly to gain control of a situation or to set the sound meter to take timed measurements. The noise meter is important for all industries, especially by using it as a mobile noise meter which is able to assess office stress levels or street noise levels. Often problems arise from noisy neighbors or if bars and restaurants are in residential areas and produce noise levels after 10 pm in excess of what local laws permit. A noise meter / sound meter will help here.We can assess which noise meter or sound meter you require in relation to the issue you have and the relating laws (requirements regarding a sound meter and a sound meter’s usage vary depending on the country). We also have noise meter microphone extension cords, tripods, sound meter calibrators and calibration certificates for most noise meter models.
-
Product
Artificial Head & Binaural Recording
-
With binaural recording systems, you can record sounds true to reality, as if you were in the sound field yourself. Our variety of artificial heads accurately reproduce all acoustically relevant components. Ear simulators with different microphones enable aurally accurate recordings, while mouth simulators allow speech playback in the transmitting direction when voice and audio quality are tested in the laboratory.
-
Product
NI-9231 and cDAQ-9171 USB Sound and Vibration Measurement Bundle
865665-01
Sound and Vibration
NI-9231 and cDAQ-9171 USB Sound and Vibration Measurement Bundle - The USB Sound and Vibration Measurement Bundle with NI-9231 and cDAQ-9171 includes the NI-9231 C Series Sound and Vibration Input Module and the cDAQ-9171 CompactDAQ Chassis for sound and vibrations measurements. This bundle provides a portable, USB-based sensor measurement system that helps you measure signals from integrated electronic piezoelectric (IEPE) and non IEPE sensors such as accelerometers, tachometers, and proximity probes. The included NI-9234 features 8 channels with built-in anti-aliasing filters that automatically adjust to your sample rate. Additionally, the bundle supports simultaneous sampling and high dynamic range measurements necessary for modern measurement microphones and accelerometers.
-
Product
ICP Microphone System
378C10
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
5G Sound Measurement
-
The combination of traditional microphones and modern technology brings portable measurement to a new level.
-
Product
ICP Electret Surface Microphone
130B40
-
Low-profile surface pressure microphone and preamp, prepolarized
-
Product
23KHZ Measurement Microphone
M23
-
The M23 is a precision engineered 23kHz omnidirectional measurement microphone ideally suited for acoustical measurements including loudspeaker design and quality control, sound system setup and troubleshooting, room acoustics, or any application where an accurate free-field measurement microphone is required.
-
Product
Advanced Tachometer
FT-2500
-
FT-2500 advanced tachometer measures the rotational speed by using the signal of change in sound, vibration or magnetic flux from rotating machines such as motor or the like.The use of FFT technology enables the FT-2500 to calculate and display the rotational speed of any complex waveform signals from microphone, sound level meter or vibration sensor by extracting the frequency component which is equivalent to the rotational speed.
-
Product
Precigrader: Acoustic MSR System
-
Precigrader is an acoustic on-line strength grading system. The system is installed in more than 150 mills. It is used to determine common commercial grades in North America, including 1650 and 2100. A spring-loaded impact mechanism strikes the lumber as it passes. The resulting vibration is captured by microphones to determine the appropriate MSR grade.
-
Product
Wireless
Beltpacks
-
Available as either single or dual channel units, the Trilogy 410 Series beltpacks are designed for 4 wire operation providing a convenient portable connection to any Trilogy intercom system. Each is fitted with a momentary ‘push to talk switch’ plus individual volume control(s) for the incoming audio level. These high performance beltpacks are suited for use with any quality low impedance headset equipped with dynamic microphone depending on the model.
-
Product
Measurement Microphone Cartridges
-
G.R.A.S. Sound & Vibration A/S
Measurement microphones are available in many types covering various frequency ranges, dynamic ranges and application situations. Selecting a microphone involves a number of choices, which can be summarized as:
-
Product
Measurement Microphone
UMM-6 USB
-
Precision condenser microphone for critical measurement and recording applicationsConnects to your PC or Mac via USB portTrue omnidirectional pattern with calibrated flat frequency responseRugged construction with high-quality componentsCompact design; includes sturdy carrying case with foam insertCompatible with most industry-standard measurement software
-
Product
Transceiver Interfaces
TI
-
Analog audio interface is a connection to transceiver audio output (external speaker connector or line output) and transceiver audio input (microphone connector or line input). Audio interface enables operating digital modes, recording and playing voice, as well as other useful functions (such as measuring levels of a signal from the air) by using a computer.
-
Product
Sound Level Indicators
-
A sound level meter is a measuring instrument used to assess noise or sound levels by measuring sound pressure. Often referred to as a sound pressure level (SPL) meter, decibel (dB) meter, noise meter or noise dosimeter, a sound level meter uses a microphone to capture sound. The sound is then evaluated within the sound level meter and acoustic measurement values are shown on the display of the sound level meter. The most common unit of acoustic measurement for sound is the decibel (dB); however, some sound level meter devices also determine the equivalent continuous sound level (Leq) and other acoustic parameters. With a portable sound level meter, industrial hygiene and workplace safety professionals can measure sound levels in multiple locations to ensure environmental conditions fall within recommended exposure limits (RELs). Some sound level meter devices can be permanently installed for continuous monitoring of sound levels at a work or job site.An important attribute to consider when searching for a suitable sound level meter is its type or class. The type or class of a sound level meter defines the device's accuracy as per American National Standards Institute (ANSI) or International Electrotechnical Commission (IEC) guidelines. Typically, "type" is the grade according to the ANSI S1.4 standard, whereas "class" is the grade according to the IEC 61672 standard. There are two types or classes assigned to sound level meters: type 1 / class 1 or type 2 / class 2. For assessing noise in basic industrial, commercial, educational, recreational or residential applications, a type 2 / class 2 sound level meter usually will suffice. For precision-grade assessments often made in a laboratory, a type 1 / class 1 sound level meter primarily is used. PCE sound level meter products are lightweight, easy-to-use and manufactured in accordance with the highest industrial standards.
-
Product
Production Line Acoustic Test Chamber
PLATC
-
The Production Line Acoustic Test Chamber from GRAS is designed for quick and qualified acoustic test of cell phones, tablet PCs, Bluetooth speaker systems etc., including frequency response, THD, Rub & Buzz and microphone test using optional sound source. The chamber has a number of connections for injecting test and control signals to the test object (DUT).Benefits include:Repeatable testing and reliable dataEasy open/close for quick and safe change of DUTFlexible test jig for easy adjustment to new DUTFlexible microphone mounting for both front/backside speakers as well as edge-mounted speakersHigh quality, high sensitive 1/4” CCP measurementmicrophone included (G.R.A.S. 46BL)Individually calibrated frequency response** Compared to reference measurement in anechoic room
-
Product
Digital Sound Meter
SM-100
-
Model SM-100 Digital Sound Meter is ideal for measuring noise levels from 30 to 130 dB with accuracy of ±1.5 dB. Model SM-100 has a frequency of 31.5 Hz to 8 kHz, three different dB ranges, and a 1/2" condenser microphone. The SM-100 has two frequency weightings: the "A" weighting ranges from 30 to 130 dB, while the °C" weighting ranges from 35 to 130 dB.





























