Contamination
-
Product
Nitrate Logger Sensor
NUL-241
-
The NeuLog nitrate sensor can be used to measure the concentration of nitrate ions (NO3-) in aqueous samples.Nitrates are used in fertilizers and can contaminate water. Also, untreated human sewage can be a source of nitrate contamination.Nitrate measurements can also be very relevant to study the nitrogen cycle in general and to relate this cycle to plants and algae.
-
Product
Constant Climate Chamber
HPP
-
Temperature range up to +70 C 3 model sizes 110, 260, 750 1 model variant: TwinDISPLAY Digitally controlled active humidification and dehumidification up to 90% Double doors as standard: Prevention of contamination and drops or rises in temperature, and at the same time an optimal view of the sensitive load through wide-area interior glass doors
-
Product
Certified Sanitary Inline Refractometer | 2″ Tri-Clamp
VIP2-3A
-
3-A Sanitary Refractometer for Food & Product Safety: Driven by concerns over food and product safety in the dairy, food, beverage, and bio-pharmaceutical industries, 3-A certified sanitary refractometers must meet exacting hygienic standards before they are awarded certification, one of the top honors attainable in the field of refractometry. Needless to say, refractometers carrying the 3-A seal meet the highest level of professional standards for the protection of public health by offering the maximum degree of protection against food or product contamination, resulting in product contact surfaces that can be easily cleaned and sanitized.
-
Product
Stealth Lumber Metal Detector
-
Stealth lumber metal detectors are custom manufactured to suit any large scale application. Ruggedly built, Stealth lumber detectors are suited for scanning an entire log and for machinery/chipper protection. The Stealth uses digital signal processing technology and has high sensitivity levels to ensure the detection of the smallest ferrous, non-ferrous and stainless steel contaminants.
-
Product
Conformal Coating Inspection (CI AOI)
-
They cover the components, the area around the components and identify most coating issues including cracks, bubbles, insufficient / excess coating, loss of adhesion and other common contaminations. Full coverage inspection for conformal coating.
-
Product
Chromatography Columns - Alumina
RediSep Alumina
-
Single use alumina columns run under normal phase conditions and offer different selectivity to silica. Neutral alumina columns are useful when samples are acid sensitive and prone to degradation on normal phase silica gel.Choose basic alumina to purify basic compounds without basic modifiers such as TEA or ammonium hydroxide. This avoids solvent swapping, washing the chromatography system, or contaminating subsequent runs.
-
Product
Phantom Pharmaceutical Metal Detector
-
The Phantom Pharmaceutical metal detector provides the ideal solution for detection and rejection of the smallest contaminants in tablets and capsules. With its current GMP design and construction suited for FDA compliance, the system meets the stringent QA requirements of the pharmaceutical industry. A free IQ/OQ Validation package is included. Built with a rugged mirrored stainless steel exterior, contact parts are all removable for cleaning without the need for tools. This compact detector can be easily angled and height-adjusted to suit any press configuration. Plus, it’s the only detector that features an electrical powered lift.
-
Product
Software
MOS Capacitance-Time Measurement and Analysis
-
Materials Development Corporation
The Capacitance-Time transient resulting from an MOS device pulsed into deep depletion reveals important information about bulk properties of the semiconductor and about damage or contaminants introduced during processing.
-
Product
Fluid Contamination Test
-
Fluid contamination testing determines the abilities of materials to withstand the contaminating fluids, to which they are exposed in service.
-
Product
Chemical Testing
-
Accolade Engineering Solutions
To ensure product environmental compliance or to gain better understanding of your materials or processes, chemical testing is often required. AES has state of the art the equipment for chemical analysis. For elemental analysis XRF, SEM/EDS or ICP can be used. For molecular analysis GCMS, HPLC and FTIR may be used. FTIR may also be used for surface analysis of contamination and our microFTIR system is suitable for the smallest samples.
-
Product
T-2/HT-2 Testing Solutions
-
T-2 and HT-2 mycotoxins are produced by Fusarium and other mold species that can commonly attack grains and can grow at temperatures from slightly above freezing to about 86°F (30°C). All domestic animals are susceptible to injury by dietary intake of T-2 in the range of a few ppm. In poultry, feed contaminated with 1.0 to 3.5 ppm of T- 2 has produced lesions at the edges of the beaks, abnormal feathering in chicks, a drastic and sudden drop in egg production, eggs with thin shells, reduced weight gains, and mortality.
-
Product
Sample Holder/Stocker For Contaminant Measurement
EDXIR-Holder
-
Measure the Samples Kept in the Holder with EDX and FTIR The Holder Can Be Used as the Sample Stocker after the Measurement
-
Product
Oil BDV Tester
-
Weshine Electric Manufacturing Co., Ltd
Insulating oil in electrical power apparatus serves two primary roles, as an insulator and a coolant. As an insulating liquid, oil’s most important property is a high dielectric strength and as a cooling liquid, a low viscosity is paramount. The principal nemeses of insulating oil are oxidation, contamination (particularly moisture, which tends to lower the dielectric properties of insulating oil), and excessive temperature.
-
Product
Soluble Salt Profiler
130 SSP
-
The Elcometer 130 Soluble Salt Profiler provides fast and accurate measurement of the level and density of soluble salts - over 4 times faster than other Bresle equivalent methods. The new Elcometer 130 Soluble Salt Profiler allows you to complete a Bresle equivalent test in just over two minutes. The multi-point conductivity sensors enable the Elcometer 130 SSP to accurately display salt concentration, showing exactly where the contamination lies and generating full colour salt density maps in 2D or 3D.
-
Product
Fourier Transform Infrared Spectrophotometer
IRTracer-100
-
This system achieves excellent sensitivity with an SN ratio of 60,000:1, high resolution at 0.25 cm-1, and high-speed scanning capable of 20 spectra/second. The performance of medium and higher end models is supported by high reliability including advanced dynamic alignment and an interferometer with a dehumidifier. This is compatible with applications active in a variety of circumstances, with a library of approximately 12,000 spectra and data analysis programs for contaminant analysis, and time course and rapid scan programs for reaction tracking.
-
Product
Carbon Sensor Resistivity Meter
HE-960R-GC(W)
-
The HE-960R-GC(W) is resistivity meter to use glass carbon for its sensor.A glass carbon sensor is not contaminated by metal elution and is chemically resistant to such wet cleaning solutions as hydrofluoric acid and hydrogen peroxide. This is especially effective for resistivity measurement in the rinse process of single-bath cleaning systems and it enables high quality control in the cleaning process.
-
Product
Hot Blocks for Acid Digestion
QBlock Series
-
QBlock series provides wide selection to choose appropriate hot block to increase efficiency of digestion and through put. Teflon coated graphite block and enclosure provides ability to produce contamination free results. Modular approach for Commander, touch screen base temperature controller helps increase life span of system and provides total control over 4 QBlock simultaneously.
-
Product
AEROTRAK™ Handheld Particle Counters
9306
-
The TSI AEROTRAK™ Handheld Particle Counters offer the most features and flexibility for customers interested in low cost and versatile particle contamination monitoring.
-
Product
Chloride/Sulfate Analyzer
Thornton 3000CS
-
The METTLER TOLEDO Thornton 3000CS Analyzer is an on-line instrument for direct measurement of chlorides and sulfates in pure water and power cycle chemistry samples. The analyzer continuously monitors these highly corrosive contaminants to assist in corrosion control and minimizing damage to critical power plant equipment. Early, unambiguous detection of trace levels of chloride and sulfate ions is provided with minimal operator supervision.
-
Product
Extreme Environment Sensors
-
For high pressure, low temperature, and high temperature applications* For applications requiring high accuracy, high reliability, and structural integrity.* Operating temperatures from -320°F to +1000°F (+1200°F short term).* Displacement systems withstand pressures up to 3500 or 5000 psi.* Dual-coil sensor design effectively minimizes radiation effects.* Hermetically sealed and laser welded.* Unaffected by environmental contaminants.
-
Product
Pulse AC Method Area Ionizers
ER-X Series
-
Panasonic Industrial Devices Sales Company of America
The ER-X Series Area Ionizers utilize the pulse AC ionization design to achieve high-speed charge removal of wide surface areas for high-volume production lines. In addition to supporting compressed air ionization, the ER-X also features both airless and low-pressure ionization modes for applications where tiny workpieces can be easily blown away. Additional features include automatic ion balance and discharge frequency control (manual control is also possible), flat discharge surface for easy cleaning, discharge needle air barrier design to reduce contamination of the needles, replaceable discharge needle unit for easy maintenance, and a dual head configuration for enhanced charge area and layout (2 different ionizer heads can be connected to a single controller).
-
Product
Code Verification Systems for Quality Inspection
-
Matrix codes enable the comprehensive and seamless traceability of goods, which turns out as significant advantage considering everyday product recalls across all industries. Whether salmonella in food, contaminated cosmetics or poor components: defective products can harm consumers, cause losses of image as well as massive economic losses. Using the 2D code, each individual article can be localized globally. Based on the specific serial number, producers and consumers can clearly identify articles if required. That represents a perfect tool for determining whether the article is subject to be withdrawn from circulation. The proper application and specification of 2D code contents allows for serious and sustainable companies to limit recalls, save costs, and to take responsibility for consumer protection.
-
Product
Safety Proximity Sensors
-
Leuze electronic GmbH + Co. KG
With their encapsulated and contactless design, safety proximity sensors are insensitive to contamination and humidity. They operate free from wear and also have a long life expectancy, even with frequent operating cycles. They are also used wherever it is difficult to precisely guide the moveable protective device. All devices feature a high-strength plastic housing. Furthermore, the devices with RFID transponder provide maximum protection against tampering.
-
Product
Geiger Counter
ONYX®
-
ONYX features a modern, streamlined look and the use of advanced technologies, making it a one-of-a-kind Geiger Counter. It weighs only 7 oz. (200g.) and measures a mere 5.1 X 2.6 X 0.9 in. (72 X 37 X 13 mm.) making it easy to transport. Despite its compact size ONYX is capable of detecting alpha, beta and gamma radiation with the same sensitivity as the IMI Inspector Alert™, and like the IMI Inspector Alert™ V2, ONYX is optimized for surface contamination measurements through use of its 2 in. pancake Geiger Mueller tube.
-
Product
PuroMaxx Contamination Control
-
Brooks offers the industry’s most advanced suite of FOUP carrier/reticle pod cleaners and photomask/reticle stockers. Using state-of-the-art humidity control along with in-situ metrology, our products address all critical airborne molecular contamination, productivity, and process stability challenges at sub20-nm nodes.
-
Product
Portable Oil Analysis Kits
-
Monitoring lubricant condition in machine wear when and where it is needed significantly reduces the time required for laboratory analysis and improves machine reliability. Spectro Scientific offers a wide range of portable devices with field simplicity and lab accuracy. The product combinations are powerful for different applications as together they provide more comprehensive analysis of oil condition, contamination and machine wear condition. All Spectro portable devices are battery powered, use small amounts of oil, and do not require solvents or chemicals to clean. They are light weight and ideal for field use.
-
Product
Surface Contamination Kit
138/2
-
The Elcometer 138/2 Surface Contamination Kit provides the user with a means for testing invisible surface contaminants including:pHchloride ionsironsalts
-
Product
Bench Top Ionizers
-
Point-Of-Use Ionizer, Adjustable (30-100 PSI) Compressed Air IonizerNeutralize Electrostatic Attraction (ESA) to control contamination by dislodging dust and debris attracted by static electricity.Detachable 7'' long ESD Protective Flexible Hose with Thumb Button Designed to for a wide range of motion and simple operation.Adjustable Balance (20 Volts) with Less Than 1 Second Discharge Time At 6 InchMeets required limits ANSI/ESD S20.20 tested per ANSI/ESDSTM3.1 and ESD TR53
-
Product
Oil Tan Delta Tester
OTD
-
The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. The microprocessor controlled inductive heater means that there is uniformity of temperature throughout the cell, in compliance with IEC 60247, and for cooling a fan effectively speeds up the cell cooling time. The instrument has a temperature measuring range of 10 to 110 C, with an accuracy of 1 C. It can be set to preheat before testing takes place. The automated oil drain facility negates the need to move the oil vessel. User safety is paramount and with this in mind, Megger have designed independent and dual redundant high voltage cut-off circuitry. If for any reason the user needs to abort the test, this can be done so by pressing any key, immediately terminating the test and removing the high voltage. The design of the cell components maximise oil fill rate but minimise turbulence in oil flow and eliminate trapping of air. With only 32 cell components, it is easy to assemble and disassemble.





























