Product
GOOSEMeter One IEC 61850 Message Monitor
IEC-61850
-
The GOOSEMeter One is an easy to use, hand held instrument that will instantaneously display the ongoing GOOSE traffic when plugged into an IEC-61850 substation’s control bus LAN
-
Product
IEC 61850-3/ IEEE 1613
-
IEC 61850 substation controllers and IEEE 1613 controllers are suitable for substation automation, T&D automation, and grid integration markets.
-
Product
Mineral Insulated Thermocouples IEC
-
Durable Mineral Insulated type thermocouples to suit a wide range of temperature measurement. Various probe types, lengths and diameters available.
-
Product
IEC Current Transformer Burden
-
• Burdens of 1A and 5A for IEC & ANSI specifications are available • 40VA, 20VA, 10VA, 7.5VA, 6.25VA, 5 VA and different combinations of these at 0.8 PF 3.75, 2.5, 1.25 & 1VA at 1.0 PF
-
Product
Accessory EFT/Burst generators IEC 61000-4-4
-
The field sources and the burst transformer are used to harden the device under test. They are powered by an EFT/burst generator.
-
Product
IEC 61000-4-5 EN61000-4-5 Lightning Surge Tester, Surge Generator
506AX
-
Shenzhen Chuangxin Instruments Co., Ltd.
Automatic lightning surge generator (or Lightning surge immunity) is used to assess the power cord and connect the internal switch stood in line to connect the internal switch to provide a common basis for switching the natural world and lightning caused by the high-energy transient interference performance. Performance fully meets the IEC 61000-4-5, EN61000-4-5 and GB/T17626.5 standards.
-
Product
IEC Potential Transformer Burdens
-
• Burdens for IEC specifications rated for various input voltages available • 2.5 to 207.5 VA at 0.8 PFIEC Potential Transformer Burdens
-
Product
An IEC 61000-4-11 Full Compliance Voltage Dip SimulatorModel: VDS-2002
VDS-2002
-
NoiseKen's new VDS-2002 offers easy and accurate test and following features: Dip, swell, interruption and variation tests up to 16A 240V single-phase AC, interruption test up to 125V DC, preset levels 0%/40%/70%/120%, open and short mode selection for interruption and optional Windows software.
-
Product
IEC 61131 Integrated Development Environment
AMAX Studio
-
Advantech IEC 61131-3 PC-based PLC integrated engineering environment for EtherCAT network eco-systemsProvides access to all five standard programming languages (FBD, LD, ST, SFC) plus variants, ensuring flexibility and adherence to the international standardIncludes integrated compilers optimized for a wide range of CPU hardware platforms to maximize the execution efficiency and performance of the controller application codeIntuitive I/O interface for AMAX-5000 Slice I/O and AMAX-4800 Block I/O, easy to proceed configuration, testing and monitoringAdd-on EtherCAT networking topology and diagnostics toolkitComplimentary data log library to save structured and time-stamped informationAgent & Data Connect (ADC) service provides flexibility and efficiency in data exchange between edge controller and supervisory gatewayValue-added provision of modular, application-oriented building blocks to accelerate project development
-
Product
IEC Standard Burden Sets (Current)
IEC Burden Sets
-
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
Product
IEC-IEEE-CSA-IS Standards
-
MOTOMEA RDS Automatic IEC-60034-2-1 Test Bench solutions are complete turnkey systems and provide a full implementation of the IEC 60034-2-1, IEEE 112-2004, CSA C390-10 standards
-
Product
MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)
-
The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.
-
Product
HardFiber System
IEC 61850
-
The HardFiber System is a KEMA tested IEC 61850 Process Bus Solution that allows the mapping of measurements made in the switchyard to protection relays located in the control house using secure communications. The HardFiber System addresses the key technical and logistic challenges affecting the labor required for substation design, construction and maintenance.
-
Product
Optical Radiation Safety Test
EN62471-C
-
IEC62471-2006(CIE S009) Photobiological Safety of Lamps and Lamp System and IEC TR62471-2(2009) Guidance on Manufacturing Requirements Relating to Non-laser Optical Radiation Safety have be published addressing hazard to human (mostly eye and skin), and are completely suitable to assess the optical radiation safety of non-laser sources, such as LED products, UV radiation in general lighting products and etc.
-
Product
Battery Extra Load Units
-
Performing capacity/discharge test on a high-capacity battery may be challenging since high requirements are set on the discharge system. In cases when discharge test times need to be reduced, high load capacities are required from the discharge system. The battery extra load unit BXL is an additional load unit designed especially for this purpose.It is primarily used with BLU battery testers. However, the unit is a universal add-on device. This means it can be used as an additional load with any other discharge/capacity tester in the market.When discharge current exceeds the capacity of a single BLU device, extra load unit increases discharge capacity. A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way in accordance to battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.
-
Product
Thermocouple Bench Selector Switches 6 or 12 Way IEC, ANSI
-
A 6 or 12 way selector in a moulded housing with aluminium front and rear panels. The rear inputs are switched via a front mounted rotary selector switch to the single output socket. Internally wired with thermocouple compensating cable and available with IEC or ANSI thermocouple types K, J, T, N & R/S.
-
Product
LAN Router
ICR-2701-S1
-
ICR-2700-S1, EMEA, 2× Ethernet, USB, Metal, Without Accessories. Security based on IEC 62443-4-2 level 1. 1.3 GB eMMC storage to host customer SW applications.
-
Product
MCB Temperature Rise and Power Loss Test Bench
-
The SCR Elektroniks 3 station MCB Temperature Rise and Power Loss Test Bench is economically designed to verify temperature rise and measure power loss as per clause 9.8 of IEC 60898 with the circuit designed to follow test procedure as per Cl 9.8.2. The temperature rise is measured in accordance with Cl 9.8.3 and 9.8.4 while power loss is measured and verified as per Table 15 of Cl 9.8.5.
-
Product
Antenna Calibration
-
TDK Test Services offers testing to domestic and international EMC test regulations, including IEC, ISO, CISPR, and SAE. Test services are offered in our 3m semi-anechoic chamber, 3m fully-anechoic chamber, 10-meter open area test site, and our shielded conducted test chamber.
-
Product
Analog Oscilloscope
PS-200
-
*20MHz Dual Trace, Dual Trigger*Vert, Sensitivity From 1mv/DIV to 15V/DIV*Sweep Rate From 10ns/DIV to 2s/DIV*Hold-off, X-Y operation*CE, UL, CUL, TUV GS, IEC 1010, EN61010
-
Product
Pyranometer products
-
Hukseflux Thermal Sensors B.V.
Hukseflux is a leading manufacturer, both in technology and market share, of pyranometers, pyrheliometers, pyrgeometers, net radiometers and albedometers.We produce a complete range of solar and longwave radiation sensors, compliant with the latest ISO, IEC and WMO standards. Each Hukseflux pyranometer is classified as ISO 9060 secondary standard, first class, or second class, and offers the best measurement accuracy in its class. Pyranometer output is analogue and/or digital (Modbus over RS-485/TTL).
-
Product
Thermocouple Connectors
-
We are Europe's largest manufacturer of thermocouple connectors and accessories in IEC, ANSI and JIS colour codes. The full range of connectors are available from stock for immediate despatch.
-
Product
Bore Gauges Xtreme 3 Digital Smart
-
• Great measuring range (2 - 300 mm)• Integrated Bluetooth® technology• Blind bore measurement from 2 to 6 mm and from 12.5 mm• Fixed anvils• UKAS certificate included with all rings• UKAS certificate included with each instrument• Manufactured according to DIN863• Memorization of 4 ring gauges values• Water and coolant resistant, protection rating IP67 according to IEC 60529• Programmable by PC• S_Connect Proximity
-
Product
Burst-Generator
SFT 1420
-
The test generator SFT 1420 simulates quick transient noise interference as they are defined in the standard IEC / EN 61000-4-4. The single pulses show a very short rise-time (5 ns) and due to this a wide RF-spectrum up to 300 MHz. RF interferences are the result.
-
Product
Automatic Dielectric Constant Tan Delta And Resistivity
-
No Balancing and Calculation required to calculate Volume / Surface Resistivityand Dielectric Constant.Complies IEC 60250, IS 4487, Test jig Conform to ASTMD 257Built in Thermal PrinterSerial port RS232 for data downloading.Can be used to check liquid sample with Three Terminal oil cell.Storage 100 Test reports
-
Product
Long Test Block (LTB)
-
The SecuControl LTB is a robust, finger-safe test block engineered for IEC substations. Paired with keyed STP test plugs and built-in CT shorting, the LTB provides make-before-break operation and patented sequential opening (trip → current → voltage) so relays can be isolated and tested without risk of open CTs or nuisance trips. Its extended rear access (long rear end) brings relay connections closer to the block for neater, more efficient cabling and flush panel integration.
-
Product
Low Power Programmable AC Source with Transients
61500 Series
-
Chroma Systems Solutions, Inc.
Power:500VA (61501)1500VA (61503)2000VA (61504)4000VA (61505)Voltage range: 0-150V/0-300V/AutoCompact size and weight attributable to advance PWM technologyAC+DC output mode for voltage DC offset simulationProgrammable slew rate setting for changing voltage and frequencyLow output impedance for testing IEC 61000-3-2 (61505)Programmable output impedance for testing IEC 61000-3-3LIST, PULSE, STEP mode function for testing power line disturbance (PLD) simulation capabilityIEC 61000-4-11 voltage dips, short and variation simulationHarmonics, inter-harmonics waveform synthesizer for testing IEC 61000-4-13Programmable voltage, current limitComprehensive measurement capability, including current harmonicsHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientAnalog programmable interface3 units combined to 3-phase power outputEasy-use software for operation and IEC regulation testOptional GPIB and RS-232C interface
-
Product
Sound Level Indicators
-
A sound level meter is a measuring instrument used to assess noise or sound levels by measuring sound pressure. Often referred to as a sound pressure level (SPL) meter, decibel (dB) meter, noise meter or noise dosimeter, a sound level meter uses a microphone to capture sound. The sound is then evaluated within the sound level meter and acoustic measurement values are shown on the display of the sound level meter. The most common unit of acoustic measurement for sound is the decibel (dB); however, some sound level meter devices also determine the equivalent continuous sound level (Leq) and other acoustic parameters. With a portable sound level meter, industrial hygiene and workplace safety professionals can measure sound levels in multiple locations to ensure environmental conditions fall within recommended exposure limits (RELs). Some sound level meter devices can be permanently installed for continuous monitoring of sound levels at a work or job site.An important attribute to consider when searching for a suitable sound level meter is its type or class. The type or class of a sound level meter defines the device's accuracy as per American National Standards Institute (ANSI) or International Electrotechnical Commission (IEC) guidelines. Typically, "type" is the grade according to the ANSI S1.4 standard, whereas "class" is the grade according to the IEC 61672 standard. There are two types or classes assigned to sound level meters: type 1 / class 1 or type 2 / class 2. For assessing noise in basic industrial, commercial, educational, recreational or residential applications, a type 2 / class 2 sound level meter usually will suffice. For precision-grade assessments often made in a laboratory, a type 1 / class 1 sound level meter primarily is used. PCE sound level meter products are lightweight, easy-to-use and manufactured in accordance with the highest industrial standards.
-
Product
K Thermocouple Surface Probe
TP746
-
Surface thermocouple Type “K” probe. Tolerance according to IEC 60584-2 standard.
-
Product
LST-2000 Laser Safety Test System
-
Hangzhou Everfine Photo-E-Info Co., LTD
The system can measure the spectral power distribution, radiant power, radiant energy, apparent light source size, pulse energy and other parameters of the laser light source, and classify the laser light source according to the standard IEC 60825.1. Because laser measurement involves more condition parameters, limit calculation and judgment process is complex, so this system adopts systematic design, the measurement complexity is simplified, the hardware adopts componentization module, users only need to follow the software prompts, carry out the corresponding steps of operation can accurately measure the effective radiation value under the corresponding conditions. The software calculates the relevant reachable emission limits and automatically classifies the laser product's safety level.