product
UV Fluorescence Sulfur Dioxide Analyzer
Model T100
The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level SO2.Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon ‘kicker’ and advanced optical design combine to prevent inaccuracies due to interferents.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel using NumaView™ Software, or via RS232, Ethernet, or USB com ports, either locally or by remote connection using the included NumaView™ Remote PC Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.The Model T100 comes with NumaView ™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView ™ Software.
-
product
MicroTCA Modules
Pixus Technologies can help you configure your MicroTCA system based on your requirements. We help you select the best modules in the industry for your application that meet your budget and performance goals. For simplicity, you can order your full OpenVPX system and boards through Pixus or we will refer you to the best fit for your application. Our flexible approach leaves the choice to you, and helps ensure you are getting the best performance and value required for your system.
-
product
Precision Chilled Mirror Reference Hygrometers
Chilled mirror dew-point hygrometers provide highly accurate and stable measurements of trace moisture and humidity. The precision chilled-mirror reference hygrometers are sensitive to changes in very low moisture concentrations (less than 5 ppbV).
-
product
Potentiostat Galvanostat
EchemLab XM
EchemLab XM includes a reference grade potentiostat and frequency response analyzer (FRA). EchemLab XM has a built-in 100 V high voltage amplifier which can be used for not only for compliance measurements but also for high voltage cell polarization. This is useful in many high solution resistance applications, for example in organic electrochemistry. In addition to high voltage, power boosters can also be integrated to combine high current and high voltage in many specialized plating applications.
-
product
Carrier Boards
ROM-DB7503
ROM-DB7503 is the Referenced Carrier Board designed for Advantech's Qseven 2.1 module. It i provides a thorough environment for module board evaluation with its completefunction support. it's more easier for the end user to design portable devices by referring ROM-DB7503 design.
-
product
Programmable S/R Standard & Simulator
5300
NAI’s 5300 Synchro/Resolver Standard & Simulator is a laboratory-grade, programmable instrument. This model can be used as a true Synchro/Resolver standard for calibrating and testing Automatic Test Equipment (ATE) for Calibration/Metrology Labs, and for Engineering Design and Production Test environments. It can also be used to measure Angle Position Indicators (API) and Synchro-to-Digital converters for static or dynamic characteristics. This model also may use an external reference waveform.
-
product
Handheld Water Quality Meters
LAQUA PC220
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
product
Dual Channel HV Amplifier with Phase Inverter
A400DI
This unit contains two independent A400 amplifiers that share common ground reference and power supply. Please see A400 page for technical details.It features also a low voltage phase inverter that inverts the signal applied to the input of channel 1. The resulting signal can then be connected to the input of channel 2 by means of a short BNC cable (supplied). As a result the two outputs operate in counter-phase. Connecting a load between the outputs effectively doubles the amplitude range. Please note that the load cannot have any connection to ground.
-
product
Synchro to Digital and Resolver to Digital Converters
Computer Conversions Corporation
Resolution: Up to 20 Bit Single-speed Resolution, Up to 24 Bits Multi-Speed Multi-Turn Resolution.Accuracy: +/- 7 to +/-19 arc seconds 20 bit, +/-40 arc seconds 16 bit, +/- 1',+/-2.3 and +/-4' Reference Inputs: 2- 11.8V 26/ 115Vrms L-L 47 to 10,000 Hz. Isolated to > 500VDCSignal Inputs: 2 - 11.8, 26, 40, 90V.L-L. Isolated to . 500VDC.Options: Multispeed synchro input and bus card interface.
-
product
User Programmable Logic
PCIe-Spartan-VI
User Programmable logic - Spartan VI 100 with 40 differential and 12 TTL IO plus PLL(24). 16 DMA ports, to support 8 full duplex byte lanes between the Bus and User FPGAs. Additional GPB interface to support R/W operations to registers etc. Driver and reference SW package includes user defined R/W to User FPGA to support User Architecture without a new driver.
-
product
1.533 Μm Frequency-Locked Laser
Thorlabs' LLD1530 Frequency-Locked Laser is a narrow linewidth, DFB-laser-diode-based, turnkey system with a vacuum emission wavelength of 1532.8323 nm and a high SMSR of at least 35 dB. The laser frequency is actively stabilized to a National Institute of Standards and Technology (NIST)-traceable molecular transition of acetylene and has an absolute accuracy at start-up that is better than ±25 MHz. The emission frequency immediately after start-up is then maintained with a ±25 MHz stability, providing an overall frequency accuracy of ±50 MHz. The LLD1530 is an accurate frequency reference designed to provide low-noise laser emission with excellent frequency stability, accuracy, and precision immediately at start-up. This source is ideal for use in demanding FTIR instrumentation, instrument calibration, gas sensing, and coherent telecommunications applications.
-
product
Automated Testing Services
Automated tests are software products. So, one must refer to the process of automating tests as to any other software development process.
-
product
Gas Filters
WITT gas filters enable the finest filtering of impurities in technical gases such as acetylene, argon., oxygen, hydrogen, methane, carbon dioxide, helium, compressed air and ethylene. They thus protect downstream equipment and systems. Some gas filters are also referred to as gas cleaners.
-
product
Ultrasonic Sensing
Ultrasonic sensing is the measurement of the time between an ultrasonic signal being sent and received. The interval between these two signals is typically referred to as time-of-flight (ToF) and depends on the distance the ultrasonic wave travels until it is reflected due to an impedance change and the speed of the ultrasonic wave. The basic equation time = distance / speed can be used to measure fluid level, fluid identification/concentration, flow, or proximity.
-
product
Ettus USRP X410, 1 MHz to 7.2 GHz, 400 MHz Bandwidth, GPS-Disciplined OCXO, USRP Software Defined Radio Device
787272-01
The Ettus USRP X410 integrates hardware and software to help you prototype high-performance wireless systems and perform over-the-air signal generation and analysis. Additionally, the Ettus USRP X410 features a two-stage superheterodyne architecture with four independent transmitter and receiver channels. It also features a Xilinx Zynq Ultrascale+ RFSoC with programmable FPGA supporting the Open Source UHD tool flow as well as LabVIEW FPGA. With these features, the Ettus USRP X410 has the RF and processing performance for applications such as wireless communications prototyping, spectrum monitoring, and signals intelligence. The Ettus USRP X410 is equipped with a GPS-disciplined 10 MHz oven-controlled crystal oscillator (OCXO) Reference Clock, which improves frequency accuracy and synchronization.
-
product
Cable Assy, Type SH100-100-Flex, 1 m
185095-01
The SH100M-100M Flex Cable, sometimes referred to as SH100-100-F, connects NI digital I/O devices to 100-pin accessories with D-SUB connectors. The SH100M-100M Flex Cable is offered in different lengths.
-
product
Blackburst & Sync Generators
provides an economical means for generating the most common SD analog composite video reference timing signals required to operate various SD analog composite video switchers, effects generators, VTRs/VCRs, cameras, video edit controllers, and other professional video equipment.
-
product
SMA Male to SMA Male Cable, 50 Ohm, 1 m
781845-01
The SMA-SMA Coaxial Cable, sometimes referred to as SMA100, connects measurement and signal devices. NI offers this 50 Ω cable in different lengths, this one is 1m.
-
product
DC to LVDT and DC to RVDT Converters
Computer Conversions Corporation
The SLVT Series are complete, low profile, continuously updating, single channel, Isolated Digital to LVDT Converters used to simulate the output of LVDT's (Linear velocity displacement transducers), RVDT's (Rotary...) and other phase/voltage sensitive AC devices. They provide a very precise linear AC voltage output proportionate to the magnitude of the input data, in or out of phase respective of the AC reference input as determined by the MSB of the input word (offset binary format).
-
product
Reference Transmitter
81492A
Keysight's 81492A Reference Transmitter is designed to offer excellent eye quality for NRZ and PAM4 signals at baud-rates up to 56 Gbaud and can serve as universal single-mode E/O converter. In addition to the internal lasers at 1310 & 1550 nm, an external optical input for usage with tunable laser sources is available. It is fully integrated into Keysight’s Optical Receiver Stress Test solutions to address test requirements of IEEE 802.3 10,40,100 and 400GBASE optical standards.
-
product
SH68M-68M-EPM, Male 68 pin SCSI to 68 pin VHDCI, 0.3m
192288-0R3
68-Pin Male VHDCI to 68-Pin Male VHDCI, Twisted Pair, Shielded Multifunction Cable - The SH68M-68M-EPM Cable, sometimes referred to as SHC68-C68-EPM, connects DAQ devices. The cable includes separate digital and analog sections, individually shielded twisted pairs for analog inputs, individually shielded analog outputs, and twisted pairs for critical digital I/O. The SH68M-68M-EPM Cable is offered in different lengths.
-
product
Microwave Wideband Synthesizer w/ Integrated VCO
ADF4371
The ADF4371 allows implementation of fractional-N or interger-N phase-loacked loop (PLL) frequency synthesizers when used with an external loop filter and an external reference frequency. The wideband microwave VCO design allows frequencies from 62.5 MHz to 32 GHz to be integrated
-
product
Thermometer Calibrators
Check-Set Series
Tel-Tru® Manufacturing Company
The Check-Set series is the perfect temperature reference device for plant quality assurance, process control, food safety, instrument calibration and service, and HACCP compliance (Hazard Analysis Critical Control Points). It is easy to use, reliable, accurate, and compatible with a wide range of dial and digital thermometers, filled system bulbs, and electronic temperature sensors.
-
product
SH68F-68F-EPM Cable , 68-Pin Female to 68-Pin Female, Twisted Pair, Shielded Multifunction Cable
199006-05
68-Pin Female to 68-Pin Female, Twisted Pair, Shielded Multifunction Cable - The SH68F-68F-EPM Cable, sometimes referred to as SH68-68-EPM, connects NI DAQ 68-pin devices to 68-pin accessories. The SH68F-68F-EPM Cable has D-type connectors and is offered in different lengths.
-
product
Low Phase Noise Reference Source
96270A
The 96270A RF Reference Source is the simplest, most accurate and cost-effective single instrument for calibrating spectrum analyzers and RF power sensors and more, up to 27 GHz.
-
product
RFID Test Instrument
RAIN Xplorer
The CISC RAIN Xplorer is a unique RFID test product developed for convenient tag frequency sensitivity, communication range, and backscatter measurements. The RFID tester is designed for open area tests and measurements in an RF-controlled environment using portable or fixed RF test chambers. The system is supplied with software and a reference tag for self-calibration.
-
product
Hydrophone
RESON TC 4038
The TC4038 is a miniature probe hydrophone, specifically designed as a standard reference hydrophone for high frequencies in the range: 100kHz to 1.2MHz. The TC4038 provides a flat frequency response and omnidirectional characteristics in the specified frequency range. The sensor element has excellent stability, which ensures reliable sensitivity over long periods of time.
-
product
Wireless Device Functional Test Reference Solution
The Keysight S8890A Wireless Device Functional Test Reference Solution provides an automation environment which is both simple to use, yet comprehensive and powerful. Based on the Test Automation Platform www.keysight.com/find/TAP, S8890A provides optional instrument driver/plug-ins offering simplified logically grouped control steps. These steps can be sequenced, looped and swept to provide powerful individual test cases or comprehensive sequences. Each driver/plug-in is provided with extensive starter sample test cases which can be modified by Keysight or the end user the UE to be tested. Plug-in options:
-
product
Source Systems AC
The power sources of MTS-series based on digital amplifier modules combined with frequency generator and reference device are the MTS source system. Single-phase systems (MTS1xx) or three-phase systems (MTS3xx) from 1 to more than 40 test positions are available.
-
product
Hardy Shaker
HI-913
This Hardy Shaker provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting a test easier. A test can be conducted on a vibration transducer and manually recorded. Multiple tests are not saved; for multiple tests use the HI-903 or HI-803 units. The HI-913 is used for testing from 7 to 10,000 Hz, it offers adjustable frequency and vibration levels. This provides a reference source for verifying the accuracy of vibration transducers, connectors, cabling and instruments or instrumentation systems. The HI-913 has a ruggedized suspension system that can support heavy transducers (up to 800 grams - see frequency limits in the manual). The HI-913 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.