References
A source of comparison.
See Also: Reference Standards, Reference Antennas, Reference Decoders, Reference Jumpers, Reference Sources, Reference Transformers, Reference Transmitters, Acoustical References, Frequency References, Solar Reference Cells
-
Product
COM-HPC Server Type Size E Reference Development Platform based on Ampere® Altra® SoC
Ampere Altra Developer Platform
-
Backed by a broad Arm® ecosystem with an Ampere® Altra® SoC at its core, using the Arm® Neoverse™ N1 platform, the Ampere Altra Developer Platform provides premium performance from a cloud-to-edge infrastructure, keeps an extremely low thermal envelope, lower TCO, and significantly lower power consumption than x86 designs. It supports the open source EDKII as bootloader with UEFI, so customers can just download a stock AArch64 (arm64) ISO such as Ubuntu and install it through booting a live ISO directly on the target. The same convenience we have become used to by using x86 / amd64 target systems.
-
Product
HandyScope HS4 DIFF: 50 MS/s 100MHz BW, 4 Channel, USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS4-50-DIFF
-
* record length is 131060 samples * 128K samples on screen without loss of information * free settable pre trigger position, from 0 to 100% * easy time axis zoom using unique scaleable sroll bar slider * free adjustable sample frequency * vertical offset and gain adjustable with graphical shiftable and scaleable axis * WYSIWYG trigger level, slope and hysteresis adjustment using combined trigger control * Auto setup to reduce setting time with unknown signals * linear/quadratical interpolation * extended cursor measurements * all settings accessable through popup menus * storing and recalling reference signals * software math channel available * easy to use speedbutton toolbar for easy access of all functions * comment tags to mark specific events in the signal * color hardcopy supported * explanatory comments with all controls * envelope mode * averaging of signals
-
Product
4-Channel 200 MHz A/D with 1532 DDCs, Kintex UltraScale FPGA - 6U VPX
Model 58865
-
- Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Complete software radio receiver solution for extremely high channel-count applications- Uses Xilinx Kintex UltraScale KU035 FPGAs- Four 200 MHz 16-bit A/Ds- Eight wideband DDCs (digital downconverters)- Up to 1524 narrowband DDCs- Sample clock generation and synchronization to an external system reference- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
Imaging Photometer & Colorimeter
LumiTop 4000 / 2700
-
Instrument Systems Optische Messtechnik GmbH
The patented optical design permits simultaneous measurement of all three sensors in one shot. The accurate spectral measurement is used as a live reference and transferred to the complete display area of the camera. This makes for extremely short measurement times and all relevant optical tests are conducted in a single test station.
-
Product
2-Channel DAQ Module
FMC150
-
Sundance Multiprocessor Technology Ltd.
The FMC150 is a dual channel ADC and dual channel DAC FMC daughter card. The card provides two 14-bit A/D channels and two 16-bit D/A channels which can be clocked by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. In addition there is one trigger input for customized sampling control. The FMC150 daughter card is mechanically and electrically compliant to the FMC standard (ANSI/VITA 57.1).
-
Product
Sound Level Indicators
-
A sound level meter is a measuring instrument used to assess noise or sound levels by measuring sound pressure. Often referred to as a sound pressure level (SPL) meter, decibel (dB) meter, noise meter or noise dosimeter, a sound level meter uses a microphone to capture sound. The sound is then evaluated within the sound level meter and acoustic measurement values are shown on the display of the sound level meter. The most common unit of acoustic measurement for sound is the decibel (dB); however, some sound level meter devices also determine the equivalent continuous sound level (Leq) and other acoustic parameters. With a portable sound level meter, industrial hygiene and workplace safety professionals can measure sound levels in multiple locations to ensure environmental conditions fall within recommended exposure limits (RELs). Some sound level meter devices can be permanently installed for continuous monitoring of sound levels at a work or job site.An important attribute to consider when searching for a suitable sound level meter is its type or class. The type or class of a sound level meter defines the device's accuracy as per American National Standards Institute (ANSI) or International Electrotechnical Commission (IEC) guidelines. Typically, "type" is the grade according to the ANSI S1.4 standard, whereas "class" is the grade according to the IEC 61672 standard. There are two types or classes assigned to sound level meters: type 1 / class 1 or type 2 / class 2. For assessing noise in basic industrial, commercial, educational, recreational or residential applications, a type 2 / class 2 sound level meter usually will suffice. For precision-grade assessments often made in a laboratory, a type 1 / class 1 sound level meter primarily is used. PCE sound level meter products are lightweight, easy-to-use and manufactured in accordance with the highest industrial standards.
-
Product
Universal PD & EMI analyzer
Spark P3
-
Doble Spark P3 is a universal partial discharge (PD) and electromagnetic interference (EMI) analyzer that uses a software defined radio signal detector to identify characteristics of insulation system deterioration that could lead to the failure of high voltage equipment. It detects signals from suitable sensors in a frequency range between 9 kHz to 2 GHz for PD and EMI, and DC to 500k Hz for acoustic and reference voltage measurements.
-
Product
16 Bit DDS Generator Up To 200 MHz
96xx series
-
The 96xx series DDS generators deliver the highest performance in both speed and resolution. The series includes produts between one and 24 synchronous channels. DDS – Direct Digital Synthesis – is a method for generating sine waves from a single, fixed-frequency reference clock and is widely used in signal generation applications. The DDS functionality implemented on Spectrum Instrumentation’s AWG platform is based on the principle of adding multiple “DDS cores” to generate a mul?ti-carrier (multi-tone) signal, with each carrier having its own well-defined frequency, amplitude and phase. In addition to these static parameters, there are also build in dynamic parameters like frequency slope and amplitude slope to allow for intrinsic linear changes for multiple cores.
-
Product
4-Channel 200 MHz A/D with Multiband DDCs, Kintex UltraScale FPGA - 3U VPX
Model 52862
-
- Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Complete radar and software radio interface solution- Supports Xilinx Kintex UltraScale FPGAs- Four 200 MHz 16-bit A/Ds- Four wideband DDCs and- 32 multiband DDCs (digital downconverters)- 5 GB of DDR4 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multimodule synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x4- Optional LVDS and gigabit serial connections to the FPGA for custom I/O- Compatible with several VITA standards including: VITA-46, VITA-48 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
SH68M-68M-EPM, Male 68 pin SCSI to 68 pin VHDCI, 0.3m
192288-0R3
-
68-Pin Male VHDCI to 68-Pin Male VHDCI, Twisted Pair, Shielded Multifunction Cable - The SH68M-68M-EPM Cable, sometimes referred to as SHC68-C68-EPM, connects DAQ devices. The cable includes separate digital and analog sections, individually shielded twisted pairs for analog inputs, individually shielded analog outputs, and twisted pairs for critical digital I/O. The SH68M-68M-EPM Cable is offered in different lengths.
-
Product
3-Channel 200 MHz A/D and 2-Channel 800 MHz D/A with Virtex-7 FPGA - XMC
Model 71720
-
- Complete radar and software radio interface solution- Supports Xilinx Virtex-7 VXT FPGAs- GateXpress supports dynamic FPGA reconfiguration across PCIe- Three 200 MHz 16-bit A/Ds- One digital upconverter- Two 800 MHz 16-bit D/As- 4 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multimodule synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x8- VITA 42.0 XMC compatible with swtiched fabric interfaces- Optional user configurable gigabit serial interface- Optional LVDS connections to the Virtex-7 FPGA for custom I/O- Supports GateXpress® FPGA-PCIe Configuration Manager- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
GPIB T8 Cable, 2-Pin Male to 2-Pin Male; Core/Clad 62.5/125 um; 1,300 nm Wavelength Fiber-Optic Cable for GPIB-140A/2 Extender
183164-100
-
2-Pin Male to 2-Pin Male; Core/Clad 62.5/125 um; 1,300 nm Wavelength Fiber-Optic Cable for GPIB-140A/2 Extender - The GPIB T8 Cable, sometimes referred to as GPIB Cable, connects your system to high-speed GPIB-140A extender devices. You can use the GPIB T8 Cable with a pair of GPIB extenders to increase the cable length of your system up to 2 km without comprising the integrity of your GPIB system or requiring any application modifications. The GPIB T8 Cable is offered in different lengths.
-
Product
Optical Probes - Low Bandwidth
P6701B/P6703B
-
Depend on Tektronix to provide you with performance you can count on, and industry-leading service and support.- Broad Wavelength Response 500 to 950 nm or 1100 to 1700 nm- High-bandwidth DC up to 1.2 GHz- High Gain 1 V/mW- Low Noise <11 pW/√Hz- Probe Connects to DPO7000*1 and DPO/DSA/MSO70000*2Series- SONET/SDH and Fibre Channel Reference Receiver Performance
-
Product
Resolver to DC Sine / Cosine or Synchro to DC
ST-RD & ST-SD
-
Computer Conversions Corporation
ST-RD and ST-SD Series - Resolver to DC Sine / Cosine or Synchro to DC Sine Cosine Packaged on PCB with Track and Terminal Block and On-Board AC Reference Supply may be used driving DC Servo amp in active position synchronizing applications
-
Product
R1005050 Ribbon Cable, 1 m
182762-01
-
The R100M-50F-50F Cable, sometimes referred to as R1005050, is a Y-shaped ribbon cable that connects to the 100-pin connector on NI digital devices. The R100M-50F-50F Cable is offered in different lengths.
-
Product
Signal Analysis
Harmonic Distortion Analysis
-
The software is used for automatic measurement of the harmonic distortion factor and voltage r.m.s. of signals coming to the input channels of FFT spectrum analyzers. Adjustment to the frequency of the main component is performed automatically. The program is based on the measurement of the voltage r.m.s. of higher components by an external or internal reference signal.
-
Product
Comparators
-
A device for comparing a measurable property or thing with a reference or standard.
-
Product
16-Channel 250 MHz A/D with DDC, Kintex UltraScale FPGA - 6U VPX
Model 58131
-
- Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Ideal radar and software radio interface solution- Supports two Xilinx Kintex UltraScale FPGAs- Sixteen 250 MHz 16-bit A/Ds- Sixteen multiband DDCs (digital downconverters)10 GB of DDR4 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x8- Optional LVDS and gigabit serial connections to the FPGA for custom I/O- Compatible with several VITA standards including: VITA-46, VITA-48 and VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available
-
Product
RS485 Null-Modem Cable, DB-9 Female to DB-9 Female, 4m
183283-04
-
9-Pin Female DB-9 to 9-Pin Female DB-9 Serial Cable - The 9F-9F Serial Cable, sometimes referred to as GPIB Serial Cable, connects and controls GPIB devices using RS232 and RS485 serial ports. The 9F-9F Serial Cable is offered in different lengths.
-
Product
PXIe Arbitrary Waveform Generator, 500 MSa/s, 16 bit, 200 MHz
M3201A
-
The M3201A PXIe arbitrary waveform generator is ideal for general purpose AWG automated test requirements. It offers high channel density with high-quality output with low phase noise. The optional real-time sequencing, intermodulation synchronization, and graphical FPGA programming software tools expand its capability to enable a number of solutions including envelope tracking (ET) and DPD (part of PA/FEM reference solution), MIMO, baseband electronics design, wireless device manufacturing, ATE, beamforming and other multi-channel coherent signal generation and multi-channel signal generation.
-
Product
Moisture Meters
-
Traceable® Moisture Meter displays material, wood, wood product, and paper moisture content 9.0 to 30.0% with a resolution of 0.1% and an accuracy of ±(4% of the reading plus 5 digits). Memory contains nine material groups such as fiberboard, construction material, and calibrations for 150 types of wood. For all other products, user establishes reference moisture readings. Once programmed, the meter reports directly in percent moisture. Simply touch a material to measure moisture. Takes only seconds. Jumbo-size digits are 1-3/8 inches high.
-
Product
T7 Fiber-Optic Cable Assembly for GPIB-140, 10 m
182805-010
-
2-Pin Male to 2-Pin Male, Core/Clad 62.5/125 um, 850 nm Wavelength Fiber-Optic Cable for GPIB-140A Extender - The GPIB T7 Cable, sometimes referred to as GPIB Cable, connects your system to high-speed GPIB-140A extender devices. You can use the GPIB T7 Cable with a GPIB extender to increase the cable length of your system up to 1 km without comprising the integrity of your GPIB system or requiring any application modifications. The GPIB T7 Cable is offered in different lengths.
-
Product
3U OpenVPX High Density Multifunction I/O Board
68CB6
-
The 68CB6 is a Configurable Open Systems Architecture™ (COSA®) 3U OpenVPX™ board that is preconfigured with 10 different “inboard” I/O, measurement and communication functions. This Combination-function Board (CB) provides a full suite of some of the most common & useful function interfaces supporting many different applications. The 68CB6 features a wide but dedicated selection of functions: Standard Functionality Discrete I/O (DT1); Successive Approximation Register (SAR) ±100 V Analog-to-Digital (AD); Isolated High Voltage Analog-to-Digital (ADF); ±10 V Digital-to-Analog (DA); Thermocouple (TC1) or Resistance Temperature Detector (RT1); Full-bridge Strain Gauge (SG1); Transmission/gear box Chip Detection and Fuzz Burn (CD1); LVDT-to-Digital linear (LD6) displacement (position) measurement, AC Reference Source output (AC2); CAN bus communication (CB8). The 68CB6 offers unparalleled programming flexibility, a wide range of operating characteristics, and a unique design that eliminates the need for external intermediate circuit considerations such as pull-up resistors or mechanical configuration jumpers. Inboard functions are software controlled and memory addressed, accessed in similar COSA® modular fashion to maintain seamless common NAI Software Support Kit & API/library structures.
-
Product
4-Channel 200 MHz A/D with 32-Channel DDC, Virtex-6 FPGA - 6U VPX
Model 57662
-
- Complete radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- Four 200 MHz 16-bit A/Ds- 32 channels of multiband DDCs (digital downconverters)- Up to 2 GB of DDR3 SDRAM- PCI Express (Gen. 1 & 2) interface up to x8- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
3-Channel 200 MHz A/D and 2-Channel 800 MHz D/A with Virtex-7 FPGA - 6U VPX
Model 57720
-
- Supports Xilinx Virtex-7 VXT FPGAs- GateXpress supports dynamic FPGA reconfiguration across PCIe- Three or six 200 MHz 16-bit A/Ds- One or two DUCs (Digital Upconverters)- Two or four 800 MHz 16-bit D/As- 4 or 8 GB of DDR3 SDRAM Sample clock synchronization to an external system reference- PCI Express (Gen. 1, 2 & 3) interface up to x8- Optional user-configurable gigabit serial interface- Optional LVDS connectionsto the Virtex-7 FPGA for custom I/O- Ruggedized and conduction-cooled versions available- Supports GateXpress® FPGA-PCIe Configuration Manager- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
4-Channel 500 MHz A/D and 4-Channel 800 MHz D/A with Virtex-6 FPGA - 6U VPX
Model 58650
-
- Complete radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- Four 500 MHz 12-bit A/Ds- Two DUCs (digital upconverters)- Four 800 MHz 16-bit D/As- Up to 4 GB of DDR3 SDRAM; or: 64 MB of QDRII+ SRAM- PCI Express (Gen. 1 & 2) interface up to x8- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
Thermocouple Vacuum Gauge Tubes
DV-6 Series for Medium Vacuum
-
Teledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-6 series thermocouple vacuum gauge tube acts as a localized sensor which is then paired with a selection of meters or controllers to provide reliable, cost-effective measurements in diverse applications. The robust sensor gauge tube is easily installed into vacuum systems and when properly excited, generates a thermoelectric voltage to provide a vacuum pressure measurement based on gas density. The DV-6 thermocouple vacuum gauge tube fully compensates for temperature and rate of temperature change.Thermocouple gauge tubes are calibrated on vacuum systems that contain N2 or Air, but can be used with other gases. Additionally, thermocouple gauges and their controllers can be recalibrated when a replacement thermocouple gauge tube is installed, following instructions in the manual. However, our DB-20 reference tube is available to confirm meter/controller performance. A complete line of installation accessories are also available to simplify the integration of our thermocouple gauge tubes into a variety of vacuum systems. Our goal is to provide “one less thing to worry about”, when performance matters! With a wide range of meter, fitting, relay and output options, the DV-6 series provides a reliable pressure measurement in numerous industries and applications.
-
Product
Electrometer
MAX4000
-
Reference grade instrument for use in a wide range of radiation therapy applications, including external beam, low dose, high dose, intravascular brachytherapy, diagnostic x-ray, and mammographic x-ray.
-
Product
PXI Millivolt Thermocouple Simulators
Series 41-760
-
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channelseach channel providing a low-voltage output across two connector pins capable of providing 20mV with 0.7V resolution, 50mV with 1.7V resolution and 100mV with 3.3V resolution, covering most thermocouple types. These thermocouple simulators use two wire outputs with a remote output reference sense to ensure the modules deliver accurate low-level voltages, even if the system has common mode voltages present. In addition, each simulation channel is also able to provide an open circuit setting to simulate faulty wiring connections to a sensor.
-
Product
nVision Reference Recorder
-
AMETEK Sensors, Test & Calibration
Accurate enough to replace a deadweight testerRugged enough to sit in 3 feet of waterPortable enough to complete calibrations anywhere





























