References
A source of comparison.
See Also: Reference Standards, Reference Antennas, Reference Decoders, Reference Jumpers, Reference Sources, Reference Transformers, Reference Transmitters, Acoustical References, Frequency References, Solar Reference Cells
-
Product
Operational Amplifiers
Op Amps
-
For designs requiring operational amplifiers (op amps), Analog Devices' portfolio of high speed op amps and precision op amps provides a broad choice of products that deliver unmatched performance. Explore op amps by parameters, and find expert system-level advice on design problems with our amplifier reference designs (Circuits from the Lab®), design tools, selection guides, calculators, and SPICE models.
-
Product
Diabetes Testing Products
-
Bio-Rad has been at the forefront in developing the world's most accurate and precise diabetes testing products. Today, Bio-Rad offers a full range of innovative HbA1c products for clinical laboratories, hospital laboratories, clinics and physician office laboratories. All Bio-Rad diabetes testing systems are NGSP (National Glycohemoglobin Standardization Program) certified, traceable to the DCCT (Diabetes Control and Complication Trials), and anchored to the IFCC reference method.
-
Product
Emissions Test System
PC-114
-
Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz. Com-Power PC-114 EMI emissions test system is a ideal solution performing pre-compliance EMC testing from 9 kHz - 1 GHz.. It has essential equipment needed for radiated and conducted EMI emissions measurements. The system includes a spectrum analyzer, antennas, near field probes, a preamplifier, LISN and a non conductive antenna tripod. Pre-compliance testing in EMC is a commonly used term not easy to define. In general, it implies testing done prior to formal testing for legal compliance. Formal legal compliance is performed at a facility designed and equipped with test instrumentation that is fully compliant with the applicable EMC standards. Such facility and instrumentation is capital intensive and can be expensive even to rent and not easily available. Compliance testing is performed per exacting requirements of the Standards and other reference documents adhering to the test methods and last detail. In addition, the test facility may require to be accredited by an accreditation body such as NVLAP, A2LA. Often it is desirable to know prior to compliance testing at such facility, whether a product is close to compliance and also how close. Pre-compliance testing is specially useful for specifications such as FCC, Part 15, EN 55022 or EN 55011 (CISPR 22 or CISPR11). Pre-compliance testing usually means using the full compliance methods but making a few educated compromises in use of site or equipment to reduce costs and testing time. Here are some benefits of pre-compliance testing.
-
Product
Solid Electrode Spectrochemical Cell
-
The spectroelectrochemical cell enables acquisition of infrared and Raman spectra of working electrode discs (variable sizes, up to 10 mm OD) under flowing solution. Working electrodes available include: Pt, Au, Ag, Cu, glassy carbon, etc. The cell uses a Pt-wire counter electrode and a Ag/AgCl reference electrode. For use with the EZpump peristaltic pump. Adapts to the Harrick Praying MantisTM Diffuse Reflection Accessory.
-
Product
Digital to Synchro Converters
DSP
Digital / Synchro Converter
Computer Conversions Corporation
The DSP Series are high efficiency, AC Reference powered, Transformer Isolated, continuously updating “whole” Digital to Synchro Converters, designed for high performance Military and Industrial applications.
-
Product
Mini Coax, Contact, ITA, RG316
610103159
Coax Contact (ITA)
Mini Coax, Contact, ITA, RG316For assembly instructions and recommended tooling please refer to p/n 610103115.
-
Product
Machine Vision Camera - 1.3 MP, 60 FPS, e2v EV76C560, Color
Flea3 USB3
-
The Flea®3 line of USB3 Vision, GigE Vision and FireWire cameras offers a variety of CMOS and CCD image sensors in a compact package. The Flea3 leverages a variety of Sony, ON Semi, and e2v sensors ranging from 0.3 MP to 5.0 MP and from 8 FPS to 120 FPS. For FLIR GigE and USB3 cameras with the latest sensors and most advanced feature sets, please refer to our Blackfly S and Oryx camera families.
-
Product
Package Testing
-
Lansmont package testing equipment is designed to perform industry standards, such as ASTM, ISTA, ISO, EUMOS and others. Our equipment is compliant with all of the most common ASTM and ISTA package testing procedures. There are individual standards that specifically reference how to perform drop testing, compression testing, side impact testing and vibration testing. In addition to those standards, there are groups of procedures referred to as distribution simulation tests, which incorporate some strategic combination of testing inputs, with the idea of simulating a typical journey through the supply chain. Some of the most common distribution simulation standards that are performed globally are published by ASTM and ISTA.
-
Product
Integrated Potentiostat and Multiplexer
EmStatMUX8
-
Based upon the EmStat range, there are two types of multiplexers to suit most types of sensor array work. The MUX8 is the most flexible offering the ability to connect arrays made of up to eight working electrodes in two or three electrode cell types and chips sharing a reference electrode and/or counter electrode. The MUX16 is suitable for sensor arrays or chips with sixteen working electrodes all sharing a RE and/or a CE. Both instruments are suitable for laminated layer corrosion analysis.The potentiostat is controlled and powered by USB and is used with PSTrace allowing for simultaneous sampling of each channel at a rate of 25 ms/channel. Standard packaging includes a shielded cable with connections for a working, a counter and a reference electrode by means of 2 mm banana connectors and mini-crocodile clips, a stripped end, Dsub-37 terminated flat cable and a USB cable. To make connections to chips simpler the Connection Terminal is an optional extra providing clearly marked screw terminals to the electrodes and can be directly joined to the ESMUX via their D-Sub connectors.
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model T300M
-
Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.
-
Product
Humidity calibration with humidity calibrator
HUMOR 20
-
The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. The humidity calibrator HUMOR 20 developed by E+E is the ideal reference instrument for these requirements and is traceable to international standards. The HUMOR 20 can be used in the humidity range of 10-95% RH both for monitoring cylindrical sensors and also for monitoring instruments with cubic dimensions.
-
Product
Comb Generator, 10 MHz to 67 GHz
U9391G
-
The Keysight Technologies, Inc. U9391G comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
Product
Measurement Of Straightness, Flatness, Positioning Uncertainty Of Round Tables
RTM - Measurement Of Positioning Uncertainty Of Indexing Tables
-
Optik Elektronik Gerätetechnik GmbH
RTM is a software for the measurement of positioning uncertainty of indexing tables using an electronic autocollimator and a polygon mirror as angle reference.
-
Product
NI-6581B, 100 MHz, 54 Single-Ended-Channel, Kintex-7 FPGA-Support, Digital I/O Adapter Module for FlexRIO
783887-01
Digital I/O Adapter
100 MHz, 54 Single-Ended-Channel, Kintex-7 FPGA-Support, Digital I/O Adapter Module for FlexRIO—The NI-6581B is a digital I/O adapter module that, when combined with a PXI FPGA Module for FlexRIO or the Controller for FlexRIO, creates a digital instrument for interfacing with 54 single-ended digital pins. A digital I/O adapter module for FlexRIO can be used to do real-time interfacing of standard protocols and implement customized protocols. The NI-6581B can operate sample digital waveforms at up to 100 MHz. It includes support for common transistor-to-transistor logic (TTL) voltage levels, or other voltage references can be sourced externally using a front panel connector.
-
Product
Range-Doppler Target Generators
ATG9100
-
The ATG-9100 is an example of a laboratory-quality instrument that will simulate complex target motion. Microwave signals from the speed camera enter the instrument through an integrated antenna which is then downconverted and digitized. Target simulation data is added to the digitized signal to provide range and Doppler information. The modified digital data is then converted back to an IF and upconverted to the original microwave frequency of the speed camera and radiated back through the antenna. Since the ATG-9100 can be phase-locked to an external 10 MHz reference standard, this instrument is suitable for use as a calibration standard for speed cameras.
-
Product
3U OpenVPX High Density Multifunction I/O Board
68CB6
Multifunction I/O
The 68CB6 is a Configurable Open Systems Architecture™ (COSA®) 3U OpenVPX™ board that is preconfigured with 10 different “inboard” I/O, measurement and communication functions. This Combination-function Board (CB) provides a full suite of some of the most common & useful function interfaces supporting many different applications. The 68CB6 features a wide but dedicated selection of functions: Standard Functionality Discrete I/O (DT1); Successive Approximation Register (SAR) ±100 V Analog-to-Digital (AD); Isolated High Voltage Analog-to-Digital (ADF); ±10 V Digital-to-Analog (DA); Thermocouple (TC1) or Resistance Temperature Detector (RT1); Full-bridge Strain Gauge (SG1); Transmission/gear box Chip Detection and Fuzz Burn (CD1); LVDT-to-Digital linear (LD6) displacement (position) measurement, AC Reference Source output (AC2); CAN bus communication (CB8). The 68CB6 offers unparalleled programming flexibility, a wide range of operating characteristics, and a unique design that eliminates the need for external intermediate circuit considerations such as pull-up resistors or mechanical configuration jumpers. Inboard functions are software controlled and memory addressed, accessed in similar COSA® modular fashion to maintain seamless common NAI Software Support Kit & API/library structures.
-
Product
Signal Analyzer
-
Choose from an extensive selection of signal analyzer products from DC to 44.5 GHz and extendable to 325 GHz.With excellent total level accuracy, dynamic range and performance, Anritsu spectrum/signal analyzers not only can capture wideband signals but FFT technology supports multifunction signal analyses in both the time and frequency domains. Moreover, the built-in signal generators on some models outputs both continuous wave (CW) and modulated signals for use as a reference signal source.
-
Product
4/8-CH 12-Bit 1 MS/s Analog Output Multi-Function DAQ PCI Express Cards
DAQe-2500 Series
Data Acquisition Module
ADLINK DAQe-2500 series are high-speed and high-performance analog output multi-function DAQ PCI EXpress cards. The devices are able to update up to 8-CH, 12-bit analog outputs simultaneously at sustaining 1 MS/s. The reference sources and the output polarities are programmable on per channel basis, combining with the multiplying DAC architecture, ADLINK DAQe-2500 series DAQ cards can generate complex modulated analog signals. The hardware-based arbitrary waveform generation frees the CPU intervention even when all analog outputs are updating at full speed, and the lengths of waveforms are only limited by the system memory.
-
Product
SH68F-68F-EPM Cable, 68-Pin Female to 68-Pin Female, Twisted Pair, Shielded Multifunction Cable
99006-10
Multifunction Cable
68-Pin Female to 68-Pin Female, Twisted Pair, Shielded Multifunction Cable - The SH68F-68F-EPM Cable, sometimes referred to as SH68-68-EPM, connects NI DAQ 68-pin devices to 68-pin accessories. The SH68F-68F-EPM Cable has D-type connectors and is offered in different lengths.
-
Product
2-Ch 500 MHz A/D with DDC & 2-Ch 800 MHz D/A with DUC, Virtex-6 FPGA - XMC
Model 71651
-
- Complete radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- Two 500 MHz 12-bit A/Ds- Two multiband DDCs (digital downconverters)- Two 800 MHz 16-bit D/As- One DUC (digital upconverter)- Multiboard programmable beamformer- Up to 2 GB of DDR3 SDRAM or 16 MB of QDRII+ SRAM- Sample clock synchronization to an external system reference- Front panel clock/sync bus for multimodule synchronization- PCI Express (Gen. 1 & 2) interface up to x8- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
4-Channel 200 MHz A/D with 32-Channel DDC with Virtex-6 FPGA - 3U VPX
Model 52662
-
- Complete radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- Four 200 MHz 16-bit A/Ds- Four multiband DDCs- Up to 2 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- 3U VPX form factors provides a compact, rugged platform- Compatible with several VITA standards including: VITA-46, VITA-48 AND VITA-65 (OpenVPX™ System Specification)- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
Reference Temperature Sensors
-
AMETEK Sensors, Test & Calibration
Our reference sensors can be used as your daily working-reference sensors in laboratory or field calibration applications. A large selection of types are available, including; straight, 90 degree angle, 4 mm or 1/4”. The superior design and specifications combined with a long history of reliability and low drift have made the STS probes the working-standard in many EN/IEC 17025 accredited laboratories worldwide. The DLC sensors are a part of our patented Dynamic Load Compensation system.
-
Product
4-Ch 1.25 GHz, 16-bit D/A with DUC, Extended Interpolation, Virtex-6 - 3U VPX
Model 52671
-
- Complete radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- Four 1.25 GHz 16-bit D/As- Four digital upconverters- Programmable output levels- Extended interpolation range from 2x to 1,048,576x- 250 MHz max. output bandwidth- 2 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- Dual µSync clock/sync bus for multimodule synchronization- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- 3U VPX form factor provides a compact, rugged platform- Compatible with several VITA standards including: VITA-46, VITA-48 and VITA-65 (Open VPX™ System Specification)- Ruggedized and conduction-cooled versions available- Synchronize up to twelve modules with Model 9192 System Synchronization and Distribution Amplifier- 1U Rack-mount
-
Product
Rubidium Reference Oscillator
LPFRS-01
-
Rubidium reference generator LPFRS-01 is designed to generate a highly stable reference and clock frequency signal.
-
Product
Chemiluminescence 03 Analyzer
Model T265
-
Teledyne Advanced Pollution Instrumentation
The Model T265 is the only commercially available US EPA Federal Reference Method for Ambient Ozone Monitoring according to the latest US EPA regulatory rules for O3. The instrument uses Chemilumescence with Nitric Oxide (NO) as a reagent, making is safe, stable, and effective for all applications. The NO-CL method for Ozone has several advantages over the conventional UV absorption technology, including the avoidance of positive and commonly found interferrents such as VOCs, fine particulates, Mercury, turpines, ClO2, and others. If these pollutants are present in the atmosphere, it can cause UV absorption analyzers to give an artificially high Ozone measurement. The innovative T265 combines speed of response, sensitivity and stability of our proven nitrogen oxide analyzer, with a simple user interface, to provide reliable ozone measurements under the harshest conditions.
-
Product
Amplifier Systems Band Specific
-
Systems are complete. They plug into an outlet and are ready to go. Our standard systems are 3U, which is 5.25″ and 5U, 8.75″. Systems are available with or without IEEE-488, RS-232 and Ethernet connectivity. Amplifiers Systems are available in both Broadband and Band-Specific frequencies. We are well-known in the industry for successfully adapting our amplifiers or custom designing new solutions to suit each unique project. Please refer to our Adapted & Custom Design Solutions link to begin formulating your performance objectives and other criteria.
-
Product
SMB Female to BNC Female Cable, 50 Ohm, 8 cm
781449-01
Coaxial Cable
The SMB-BNC Coaxial Cable, sometimes referred to as SMB-100 or SMB-110, connects measurement and signal devices. NI offers this 50 Ω cable in different lengths and quantities.
-
Product
L-Band RF Tuner and 2-Channel 500 MHz A/D with Virtex-7 FPGA - 6U VPX
Model 57791
-
- Accepts RF Signals from 925 MHz to 2175 MHz- One programmable LNA handles L-Band input signal levels from -50 dBm to +10 dBm- Programmable analog downconverter provides IF or I+Q baseband signals at frequencies up to 123 MHz- Two 500 MHz 12-bit A/Ds digitize IF or I+Q signals synchronously; optional: 400 MHz 14-bit A/Ds- Two FPGA-based multiband digital downconvertersXilinx Virtex-7 VX330T or VX690T FPGAs- 4 GB of DDR3 SDRAM- Sample clock synchronization to an external system reference- PCI Express (Gen. 1, 2 & 3) interface, up to x8- Clock/sync bus for multimodule synchronization- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-7 FPGA for custom I/O- Supports GateXpress® FPGA-PCIe Configuration Manager- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe
-
Product
Mid-Range Gas Filter Correlation Carbon Dioxide Analyzer
Model T360M
-
The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Appearance
-
Konica Minolta Sensing Americas, Inc
For maximum impact, the surface quality of an automotive paint finish must instantly produce an appealing visual sensation for the customer. A high-quality paint finish is not only described by color but also brilliance (“gloss”) and smoothness, often referred to as DOI (Distinctness of Image). This can only be achieved if the overall surface finish displays both high QUALITY and HARMONY.





























