Filter Results By:
Products
Applications
Manufacturers
-
product
Charge Sensitive Preamplifier-Discriminator
A101
Model A101 is a hybrid charge sensitive preamplifier, discriminator, and pulse shaper developed especially for instrumentation employing photomultiplier tubes, channel electron multipliers and other low capacitance charge producing detectors in the pulse counting mode. The A101 is widely used in laboratory and commercial applications for mass spectrometers, laboratory and research experiments, aerospace instrumentation, medical electronics, and electro-optical systems.
-
product
Preamplifiers
Is an electronic amplifier that converts a weak electrical signal into an output signal strong enough to be noise-tolerant and strong enough for further processing, or for sending to a power amplifier and a loudspeaker.
-
product
Preamplifiers
Preamplifiers recognize the extremely low amplitude AE signal produced from AE sensors, and convert the signals into amplified and usable forms. As applications and testing conditions vary, project needs may change as well. Physical Acoustics offers an entire line of preamplifiers for a variety of testing requirements. Operating in conjunction with our specialized AE software, preamplifiers also moderate signal size during the data collection process, helping to produce accurate results.
-
product
Preamplifiers
A.H. Systems'' Preamplifier line is an excellent choice with a rugged design, no hassles with soldering your own power leads and they improve overall system sensitivity by at least 20 dB. All of A.H. Systems'' Preamplifiers come with a 12-volt (or 15-volt) DC regulated power source. A low voltage indicator confidently allows you to power the amplifier with your own external 12-volt DC battery. This makes it a convenient choice for field measurements. See table below for amplifier specifications.
-
product
Transformer Preamplifier
SR554
Stanford Research Systems, Inc.
The SR554 is a low-noise, transformer-coupled preamplifier optimized for source impedances between 0.05 Ω and 1 kΩ. With an input noise of only 0.1 nV/√Hz, the SR554 can be used in a wide range of low-noise applications.
-
product
Preamplifiers
The primary function of a preamplifier is to extract the signal from the detector without significantly degrading the intrinsic signal-to noise ratio. Three basic types of preamplifiers are available: the current-sensitive preamplifier, the parasitic-capacitance preamplifier, and the charge-sensitive preamplifier. ORTEC manufactures a preamplifier to fit your detector, your application, and your budget.
-
product
Microphone Preamplifier
HT426E01
Nominal Microphone Diameter1/2Frequency Response Electrical Noise(at 22 C) (Flat 20 Hz to 20 kHz)Distortion (3 V rms input at 1 kHz)<-70 dB<-70 dB[1] EnvironmentalTemperature Range (Operating)-40 to +248 FExcitation Voltage 20 to 32 Constant Current Excitation 2 to 10 mA
-
product
Microphone Preamplifier
426A11
1/2-inch ICP preamplifier with gain and filter switches (for prepolarized microphones)ICP(R) low noise preamplifier with gain, filters, and TEDS
-
product
Preamplifiers
Com-Power broadband high gain preamplifiers were designed for electromagnetic interference (EMI) testing and certification. EMC test labs use preamplifiers to improve sensitivity of the test system during EMI radiated emissions measurements. Without a high gain preamplifier, signals picked by the antenna that have amplitudes below the noise floor of the test system cannot be measured. The preamplifier gain has minimum variations for the entire operating frequency range for accurate emissions measurements. The Com-Power preamplifiers were primarily intended for EMC applications. However, it can be used for other applications that require signal amplification.
-
product
Highly Sensitive Silica Monitor
SLIA-300
The ultra-pure water that is used in the semiconductor production processes can be further purified by using an ion-exchange resin. Capturing the silica that is dissolved from this ion-exchange resin as quickly as possible can control the ultra-pure water quality, which is important during the production processes.HORIBA Advanced Techno has developed and employed a new "long light path length measurement cell" to enable highly sensitive measurement of ultra-low density silica and also realized a compact desktop model to improve the usability.
-
product
Microphone Preamplifier
426B31
Performance:Nominal Microphone Diameter:1/4" Frequency Response:3.98 to 126000 Hz3.98 to 126000 10.0 to 126000 Hz10.0 to 126000 HzElectrical Noise (A-weight)3.8 TEDS CompliantYes
-
product
Dual-Mode Charge Amplifiers
Dual-mode charge amplifiers represent a versatile solution for both piezoelectric charge mode and ICP® sensors. Among the advanced features offered by models 443B01, 443B02 and 2775C are an ultra-low noise floor, sensor fault detection, overload detection, a built-in calibration reference signal, and an RS-232 port for seamless computer control. Notably, model 443B02 features a long discharge time constant selection, ideal for capturing quasi-static events lasting several seconds, a capability particularly beneficial for ballistics and ammunition testing applications. Model 2775C features AC, DC, and servo outputs.
-
product
Charge Integrator Amplifiers
AD8488
Analog Devices’ charge integrator amplifiers convert the charge acquired by X-ray or photodiode detectors to a voltage. The channels are composed of CMOS transistors, using typical high input impedance CMOS gates. The integrators generate charge dependent voltages using a range of selectable capacitance values that accommodate a broad range of input charge values. The integrators are followed by single-ended input to differential output voltage amplifiers where offset and low frequency noise voltages are subtracted from the input voltages.
-
product
DC-DC Charge Pumps
Charge pumps – inductorless boost converters – from ams operate at up to 90% efficiency.
-
product
Microphone preamplifier
PRE-01
The microphone preamplifier PRE-01 has been designed to match Audiomatica’s microphones MIC-01, MIC-02 andMIC-03. It is particularly useful when the microphone has to be operated far from the analyzer or when weighted measurements are needed. PRE-01 powers the microphone connected to its input with an 8.2V phantom supplyand adds a selectable weighting filter (A or B or C); also available there is a 20 dB gain stage
-
product
Mm-Wave High Sensitive Power Meters
The DPM-xx is a single-channel average power meter for RF to millimeter wave frequencies that measures absolute power from 10 MHz to 220 GHz.
-
product
In-Line Charge Amplifiers
The in-line charge amplifier is used to excite structures or machinery with a definable impulse force. Resonances are identified by impulse, an important measurement parameter for the study of dynamic behavior. The 4705A1 is a fast turn on time, 50 mV/pc, in line charge amplifier with BNC jack connectors on each side.
-
product
Charge Plate Monitors
Our charge plate monitors the voltage of the battery and the voltage of the battery.
-
product
DC/DC with UPS and Charge Controller
A wide input range, quad output PC/104-Plus DC/DC converter with a built-in battery charger and uninterruptable power supply (UPS) controller. Designed for harsh environments, the power supply operates from -40 to +85C without a fan or heatsink making it ideal for industrial applications.
-
product
Preamplifier
2721
Pre-amplification is required to protect the output signal of pH and ORP electrodes from a wide variety of electromagnetic interferences common in industrial environments. Signet 2721 is used if remote pre-amplification is required (e.g. tank temperature >80oC) or connecting another manufacturer's electrode to the Signet 5700 or 8750 instrument. The Signet 2721 should be used with special order sensors built with cables (Signet models 277X-HT or 277X-1-HT).
-
product
Time Sensitive Networks
Time Sensitive Network (TSN) standards enable deterministic real-time communication over Ethernet, allowing solutions to be built to provide extremely precise, predictable timing and control across the network. By adding features to Ethernet such as time synchronization, ingress policing, seamless redundancy, frame preemption, scheduled traffic, and stream reservation, TSN ensures data is not delayed by the network.
-
product
RX Pre-Amplifier System
RAM-34
The RAM-34 is a complete pre-amplifier system designed primarily for the low bands 160M thru 40M. It has inputs for four receive antennas and internal 3-pole bandpass filters for 160M, 80M and 40M. In addition to the pre-amplifier, it has a step attenuator that togetherwith the amplifier stage provides gains from -20 dB to +20 dB in 5 dB steps. This allows equalizing the signal levels between the antenna inputs. Gain settings are memorized for each antenna on each band. Different types of receive antennas have different signal levels and the gain memories eliminate the need to adjust the receiver or pre-amplifier when switching between the antennas.
-
product
Battery Charge and Discharge Tester
HTCFDK / 791
Wuhan Huatian Electric Power Automation Co., Ltd.
The voltage monitoring information of single battery is simple, safe and accurate with wireless relay access.
-
product
High-Sensitivity Tri-Axial Accelerometer with Built-In Preamplifier
NP-7310
NP-7310 is the accelerometer with built-in preamplifier, and capable of tri–axial directions simultaneous measurement. It is suitable for the low frequency vibration measurement such as ground vibration or floor vibration while operating the machine. NP-7310 can be used with the sensor amplifier unit such as AU-2100, AU-2300 or PS-1300. Also, it is possible to input directly to the analyzer or recorder which the constant current amplifier is built-in such as the FFT Analyzer of DS-2000 series, DS-3000 series, CF-7200A, CF-9000 series or CF-3650/3850 series.
-
product
Quartz Charge Force Rings
Ring-style sensor configurations measure dynamic compression. Tension measurements are also possible if the unit has been installed with proper pre-load.
-
product
DryLoc pH/ORP Preamplifier and Connectors
2760
The 2760 preamplifier allows any DryLoc pH/ORP electrode to work with Signet ProcessPro and ProPoint pH/ORP instruments. It is also sold as a simple connector for use with other manufacturers' instruments that do not require a preamplified signal.
-
product
X-Ray Preamplifier Power Supply
The X-ray Preamplifier Power Supply (XPPS) provides power for 50 or more preamplifiers. The 19-inch rack-mount or benchtop unit contains linear power supplies that generate +/-12V @ 5.1 Amperes and +/-24V @ 3.6 Amperes, with very little noise.
-
product
Battery Charge And Discharge Test System
9841
*Easy user interface*Measure Voltage, Current, Power, KWH, AH, Temperature, Reference Voltage*Accuracy Measure Time*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery. *The test result will be stored to ACCESS data
-
product
Externally Polarized Precision Condenser Microphones & Preamplifiers
Externally polarized microphones set the initial standard for all acoustic test and measurement applications. They rely on a dedicated 200V power supply and specialized cables with 7-pin LEMO® connectors. Their straightforward design supports a wide product range. Often chosen as replacements for existing models or when prepolarized alternatives are unavailable.